Benefit kWh rate power supply/local shift value weather dependent
00
Switching off heaters
0
0/1/2/3
1
—
01
Unit connection to benefit kWh rate power supply
0 (OFF)
0/1/2
1
—
02
Not applicable. Do not change the default value.
—
—
—
—
03
Local shift value weather dependent
0 (OFF)
0/1/2/3/4
1
—
04
Not applicable. Do not change the default value.
—
—
—
—
05
Pump operation is active during benefit kWh rate
power supply and [D-00]=0 or 1 (backup heater
forced off) setting
1
0/1
1
—
06
Not applicable. Do not change the default value.
—
—
—
—
E
Unit information readout
00
Software version
Read only
—
—
01
EEPROM version
Read only
—
—
02
Unit model identification
Do not change the default value
Depending
on model
—
—
03
Liquid refrigerant temperature
Read only
1
°C
04
Inlet water temperature
Read only
1
°C
F
Option setup
00
Pump operation stop
0
0/1
—
—
01
Space cooling permission temperature
20
10~35
1
°C
02
Bottom plate heater ON temperature
3
3~10
1
°C
03
Bottom plate heater hysteresis
5
2~5
1
°C
04
Functionality of X14A
(b)
1
0/1
—
—
Underfloor heating screed dry-out program
05
Action number selection
1
1~20
1
—
06
Heating set point of selected action number [F-05]
25.0
(c)
25~55
1
°C
07
Time of selected action number [F-05]
0
(c)
0~72
12
hour
08
Underfloor heating screed dry-out program
enabled/disabled
0 (OFF)
0/1
1
—
09
Latest action number executed
0
0~21
(Read only)
0
—
(a) Domestic hot water tank without built-in booster heater.
(b) Only possible to modify the first 3 minutes after power ON.
(c) For all action numbers of [F-05].
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value