Place the unit in the appropriate installation location.
The weight of the unit is approximately 74 kg. At least two
persons are required to lift the unit.
Use the plates delivered with the unit to lift the unit.
■
Level the unit to a stable position using the levelling feet. The
maximum allowed deviation from a horizontal position is 1°.
■
Fix the side plates with the appropriate screws.
■
Close the decoration panel(s) which will be on the wall side and
for which fixation is not possible anymore after the unit is put on
its final location.
6.4.
Installing the unit
Preparations before installation on final installation place
After unpacking the unit and before installing the unit on its final
installation position, following preparations need to be done:
■
Open the unit
Refer to the
"5.1. Opening the unit" on page 9
.
■
Knock out the needed knockout holes.
This installation instruction consists of installation of
■
refrigerant piping,
■
water piping and
■
electrical wiring.
For each of these a dedicated knock out hole is foreseen at the
backside of the unit:
1
Knock out hole for refrigerant piping
2
Knock out hole for electrical wiring
3
Knock out hole for water inlet piping
4
Knock out hole for water outlet piping
A
Left installation
B
Right installation
To punch a knockout hole, punch it with a hammer, remove all
burrs and install the supplied grommets (see
"4. Accessories" on
page 9
).
1
Knockout hole
2
Burr
3
Grommet
■
Take out all accessories from the indoor unit.
The flexible water piping, valves, accessory bag, and remote
controller kit are located behind the back plate.
■
Standard installation location of the optional domestic
hot water tank is on top of the indoor unit.
If available service space to left and/or right side is
limited, carefully consider all tank module installation
steps first.
74 kg
1
°
2x
2x
NOTICE
■
Knockout holes are foreseen at both sides of the
unit. Pay attention to knock out the correct holes
depending on your installation location.
■
Refrigerant piping and water piping must go
through different knockout holes.
■
The electrical wiring must always enter the unit
at the upper knockout holes at the left side of the
unit (see the figure above).