Daikin EKCBX008BBV3 Operation Manual Download Page 4

Operation manual

3

EKCBX/H008BBV3

Unit for air to water heat pump system

4PW67442-1A – 12.2010

4.

O

PERATING

 

THE

 

UNIT

4.1.

Introduction

The heat pump system is designed to provide you a comfortable
indoor climate for many years at low energy consumption.

To get the most comfort with the lowest energy consumption out of
your system, it is very important to observe the items listed below.

Defining possible schedule timer actions for each day and filling out
the form at the very end of this manual can help you minimize the
energy consumption. Ask your installer for support if required.

Make sure the heat pump system works at the lowest possible
hot water temperature required to heat your house.

To optimize this, make sure the weather dependent set point is
used and configured to match the installation environment.
Refer to 

"Field settings" on page 13

.

It is advised to install a room thermostat connected to the indoor
unit. This will prevent excessive space heating and will stop the
unit and the circulation pump when the room temperature is
above the thermostat set point.

Next recommendations only apply to installations with an
optional domestic hot water tank.

Make sure the domestic hot water is only heated up to the
domestic hot water temperature you require.
Start with a low domestic hot water temperature set point
(e.g. 45°C), and only increase if you feel that the domestic
hot water supply temperature is not sufficient.

Make sure the domestic water heating by booster heater only
start 1 to 2 hours before you expect domestic hot water
usage.
In case you only need a lot of domestic hot water in the
evening or in the morning, only allow domestic water heating
by booster heater during early morning and early evening.
Also keep hours with low electricity cost tariffs in mind.
To do this, program both the domestic water heating and
booster heating schedule timer. Refer to Programming in
chapter 

"Programming and consulting the schedule timer" on

page 9

.

If the domestic hot water is not used for two weeks or more, a
quantity of hydrogen gas which is highly flammable may
accumulate in the domestic hot water tank. To dissipate this
gas safely, it is recommended that a hot tap be turned on for
several minutes at a sink, basin, or bath, but not at a
dishwasher, clothes washer or other appliance. During this
procedure there must be no smoking, open flame or any
electrical appliance operating nearby. If hydrogen is
discharged through the tap, it will probably make a sound as
of air escaping.

4.2.

Operating the digital controller

Operating the unit comes down to operating the digital controller.

Features and functions

The digital controller is a state of the art controller that offers full
control over your installation. It can control a heating/cooling and a
heating only installation.

Both installations are available in multiple versions which vary in
capacity, electrical supply and installed equipment (with an optional
domestic hot water tank with a booster heater).

Basic controller functions

The basic controller functions are:

Turning the unit ON/OFF.

Operation mode change-over:
-

space heating (refer to 

page 6

),

-

space cooling (refer to 

page 6

) (*),

-

domestic water heating (refer to 

page 6

) (*).

Selection of features:
-

quiet mode (refer to 

page 7

),

-

weather dependent control (refer to 

page 7

).

Temperature set point adjustment (refer to 

page 7

).

The digital controller supports a power cut off of maximum 2 hours.
When autorestart is enabled (see 

"Field settings" on page 13

) this

allows a power supply shut down of 2 hours without user intervention
(e.g. benefit kWh rate power supply).

Clock function

The clock functions are:

24 hour real time clock.

Day of the week indicator.

Schedule timer function

The schedule timer function allows the user to schedule the operation
of the installation according to a daily or a weekly program.

CAUTION

Never let the digital controller get wet. This may cause an
electric shock or fire.

Never press the buttons of the digital controller with a hard,
pointed object. This may damage the digital controller.

Never inspect or service the digital controller yourself, ask
a qualified service person to do this.

Descriptions in this manual that apply to a specific
installation or that depend on the installed equipment,
are marked with an asterisk (*).

Some functions described in this manual may not be
available or should not be available. Ask your installer
or your local dealer for more information on
permission levels.

INFORMATION

(*) The functions 'space cooling' and 'domestic water
heating' can only be selected when the corresponding
equipment is installed.

Summary of Contents for EKCBX008BBV3

Page 1: ...OPERATION MANUAL EKCBX008BBV3 EKCBH008BBV3 Unit for air to water heat pump system...

Page 2: ...manual speci ed for a certain product or application explaining how to install con gure and maintain it Operation manual Instruction manual speci ed for a certain product or application explaining how...

Page 3: ...er Refer to the operation manual of the indoor unit and to the installation manual of the digital I O PCB for more information Refer to the wiring diagram or connection diagram for connecting this PCB...

Page 4: ...tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open ame or any electrical applia...

Page 5: ...9 OFF ICON x This icon indicates that the OFF action is selected when programming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installatio...

Page 6: ...ing the clock 33 DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS wbi and wbj These buttons are used to adjust the current set point of the domestic hot water temperature only for 4 03 0 1 2 or 3 These b...

Page 7: ...unit will immediately heat up the domestic water tank untill domestic hot water storage set point upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a sc...

Page 8: ...isappears from the display Selecting powerful domestic water heating operation 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start ashing Powerful domesti...

Page 9: ...t water temperature INFORMATION Only use the pr button to enable or disable the schedule timer The schedule timer overrules the y button The y button only overrules the schedule timer until the next p...

Page 10: ...e schedule timer remind Familiarise yourself with the icons and the buttons You will need them when programming Refer to Name and function of buttons and icons on page 4 Fill out the form at the very...

Page 11: ...8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the temperature by me...

Page 12: ...on time 8 Use the ba button to select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation Fo...

Page 13: ...e next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to selec...

Page 14: ...D SET MODE The icon 3 will be displayed The current selected eld setting code is indicated 2 with the set value displayed to the right 1 2 Press the bgi button to select the appropriate eld setting rs...

Page 15: ...rature Lo_A Note that the Lo_Ti value should be higher than Hi_Ti as for low outdoor temperatures i e Lo_A warmer water is required 1 03 Set point at high ambient temperature Hi_Ti the target outgoing...

Page 16: ...g Scheduled domestic hot water storage The storage set point can be accessed directly using the wi and wj buttons 6 03 Scheduled storage de nes whether the scheduled domestic water heating storage dur...

Page 17: ...omestic hot water user interface set point 9 Heating and cooling set point ranges The purpose of this eld setting is to prevent the user from selecting a wrong i e too hot or too cold leaving water te...

Page 18: ...d settings of the weather dependent set point 1 E Unit information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model...

Page 19: ...eating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting 04 Not applicable Do not change the...

Page 20: ...lated setting 05 Not applicable Do not change the default setting d Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting...

Page 21: ...li ed installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is dispo...

Page 22: ...NOTES NOTES...

Page 23: ......

Page 24: ...Copyright 2010 Daikin 4PW67442 1A 12 2010...

Reviews: