Operation manual
11
EKCBX/H008BBV3
Unit for air to water heat pump system
4PW67442-1A – 12.2010
Programming quiet mode, booster heating or domestic water
heating
Programming space cooling, quiet mode, or booster heater mode is
carried out as follows:
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to program (space cooling
c
, quiet mode
s
, or booster heating
m
).
The selected mode is blinking.
3
Press the
<
button to confirm the selected mode.
The first programmed action is displayed.
4
Use the
pi
and
pj
buttons to consult the programmed
actions.
This is called the readout mode. Empty program actions (e.g. 3
and 4) are not displayed.
5
Press the
<
button for 5 seconds to enter the programming
mode.
6
Use the
<
button to select the action number you would like to
program or to modify.
7
Use the
pi
and
pj
buttons to set the correct action time.
8
Use the
ba
button to select:
■
For space cooling:
-
x
: switch cooling and the controller off.
-
9
: set the temperature by means of the
bi
and
bj
buttons.
-
a
: to select automatic temperature calculation.
■
For quiet mode and booster heater mode use the
ba
button
to enable or disable the
x
action.
9
to program the other actions of the selected
mode.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
10
Press the
<
button for 5 seconds to store the programmed
actions.
If the
<
button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 is deleted.
You automatically return to step
. By pressing the
pr
button
several times, you return to previous steps in this procedure and
finally return to normal operation.
5 sec
5 sec
5 sec
5 sec
INFORMATION
Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the
pr
button.
INFORMATION
Programming the booster heater operationtime is only
valid if field setting [4-03]=1, 2, or 3.