EHVH/X16
Daikin Altherma - Low Temperature Split
4P313777-1 – 2012.05
Installer reference guide
82
14 Technical data
14.10 Combination table
oooo
oooo
oooo
oooo
oooo
oooo
oooo
oooo
o
o
(5
)
o
o (5
)
o
o
(5
)
o
o (5
)
o
o
(5
)
o
o (5
)
oooo
---
---
o
---
*RLQ006CA*V3*
*RLQ008CA*V3*
*RHQ011B*(V3/W1)
*RHQ011B*(V3/W1)
*RHQ014B*(V3/W1)
*RHQ016B*(V3/W1)
*RLQ011C*(V3/W1)
o-
--
--
-
--
-
*RLQ004CA*V3*
*RLQ006CA*V3*
*RLQ008CA*V3*
---
o
o
---
---
o
o
---
---
---
---
---
o
---
---
---
---
---
---
---
---
---
o
o
---
---
o
o
*RLQ016C*(V3/W1)
---
---
---
---
o
o
o
oo
---
---
---
---
*RLQ014C*(V3/W1)
---
---
---
---
oo
---
*RHQ014B*(V3/W1)
*RHQ016B*(V3/W1)
*RLQ011C*(V3/W1)
oo
--
-
oo
o
o
o
--- (
8
)
---
---
---
---
---
# -
##
o
o
o
--- (
8
)
---
---
*RLQ014C*(V3/W1)
*RLQ016C*(V3/W1)
---
---
--- (
8
)
*RLQ004CA*V3*
---
---
---
---
---
---
---
---
---
oo
oooo
--
o
o
--
o
o
--
o
o
--
o
o
oo
-
-
--
o
o
3D078227-1
oooo
18 - 3V
26 - 9W
18 - 3V
26 - 9W
18 - 3V
18 - 3V
oo
--
--
--
--
oo
--
04 #
- #
#
18 - 3V
26 - 9W
(9)
18 - 3V
# -
##
26 - 9W
(9)
De
s
c
ri
p
tio
n
D
e
s
c
rip
tio
n
Heat
ing o
n
ly
mo
de
l *
H
VH*
H
eat
ing o
n
ly
mo
de
l *
H
VH*
R
e
ver
s
ib
le
mode
l *
H
VX*
R
ever
si
bl
e mo
de
l *
H
VX*
B
a
c
k
up
he
at
er
3k
W 1N~230 V
B
ac
k
up he
at
er
3k
W 1N~230 V
B
a
c
k
up
he
at
er
6k
W 1N~230 V
B
ac
k
up he
at
er
6k
W 1N~230 V
B
a
c
k
up
he
at
er
6k
W 3N~400 V
B
ac
k
up he
at
er
6k
W 3N~400 V
B
a
c
k
up
he
at
er
6k
W 3~
230 V
B
ac
k
up he
at
er
6k
W 3~
230 V
B
a
c
k
up
he
at
er
9k
W 3N~400 V
B
ac
k
up he
at
er
9k
W 3N~400 V
Dom
e
st
ic hot
wat
e
r t
a
nk
180L
Do
m
e
st
ic hot
wat
e
r t
a
nk
180L
Dom
e
st
ic hot
wat
e
r t
a
nk
260L
Do
m
e
st
ic hot
wat
e
r t
a
nk
260L
Outdoor com
b
in
ati
on tabl
e for *HV(H/X)(04/08)S
(18/26)CA
* and *
H
B
(H/X)16S(18/26)CA
*
*H
VH
04S
1
8
C
A
*
H
e
ating
only indoor unit
*H
VX
04
S
1
8C
A
*
Reversible indoor unit
*H
VH
08S
(18/2
6
)C
A
*
H
e
ating
only indoor unit
*H
VX
08
S
(18/2
6
)C
A
*
Reversible indoor unit
*H
VH
16S
(18/2
6
)C
A
*
H
e
ating
only indoor unit
*H
VX
16
S
(18/2
6
)C
A
*
Reversible indoor unit
Ki
t avai
la
bi
li
ty for outdoor uni
ts
EKDP008CA
D
ra
in
pan k
it
*KDK04
Dr
ai
n pl
ug k
it
(
3
)
*KBPHTH16A
B
o
tt
o
m
plat
e heat
er
(
1
) (
3
) (
10)
*K01
6S
NC
S
n
ow cover
K
it av
ai
lability
Reference
D
escri
p
ti
on
Heat
ing o
n
ly
mo
de
l *
H
VH*
Reversi
b
le
mode
l *
H
VX*
*KRS
C
A
1
R
em
ote sensor for ou
tdoor (1
1
)
KRC
S
01
-1
Rem
o
te sensor for indoor (11)
*KRUCAL1
User
i
n
te
rf
ace l
a
ng
uag
e
gr
oup
1
*KRUC
A
L2
User
i
n
te
rf
ace l
a
ng
uag
e
gr
oup
2
*KRP1HB
A
A
Dig
ital I/O PC
B (2)
*KRP1AHTA
D
em
and PCB
(
6
)
*KRT
W
A
W
ired room
therm
o
stat option kit
*KRT
R1
W
ireless room
therm
o
stat
op
tion
kit (in
c
l.
receiver)
*KRTETS
e
xt
er
nal t
e
m
p
e
rat
ur
e s
e
ns
or
o
p
ti
on k
it
(
4
)
FWXV15AVEB
H
eat
pump conv
ect
o
r
FWXV20AVEB
H
eat
pump conv
ect
o
r
*KVKHPC
V
al
ve k
it
heat
p
u
mp co
nv
ect
o
r (
5
)
*K
P
C
C
A
B1
P
C
ca
ble kit (1
2
)
AvailabilityTBC
Remark: Other combinations than mentioned in this combination table are prohibited
(1) Heater tape that can be fixed on the bottom plate to prevent excessive ice formation.
(2) PCB that provides additional output connections:
(a) Control external heat source (bivalent operation)
(b) Output remote ON/OFF signal Space heating/cooling
OR
bottom plate heater *KBPHTH16* control
(c) Remote alarm output
(3) It is not allowed to combine bottom plate heater and drain plug/stop kit
(4) *KRTETS can only be used in combination with *KRTR1
(5) Valve kit mandatory if heat pump convector is installed on reversible model (not mandatory for heating only model)
(6) PCB to receive up to 4 digital inputs for power limitation, only for *HB(H/X)04/08CA
(8) Bottom plate heater is factory mounted and controlled by outdoor unit.
(9) Unified model, the actual BUH capacity depends on the actual internal upwiring
(10) Requires digital I/O PCB *KRP1HBAA
(11) Only 1 remote sensor can be connected : indoor OR outdoor sensor
(12) Data cable for connection with PC
Factory mounted optional equipment for *HV(H/X)08S#CA## and
*HV(H/X)16S#CA##
Factory
mounted opti
onal
equipm
ent for
*HV
(H/X)0
4
S
#
CA
##
AvailabilityTBC