background image

4 Operation

User reference guide

8

EHBH/X04~16CB + EHVH/X04~16S18+26CB

Daikin Altherma – Low temperature split

4P384964-1 – 2015.01

Leaving water temperature control

Leaving  water  temperature  control  means  that  you  only  control  the
leaving water temperature. To control the leaving water temperature,
you can do the following:

You can…

Location

Read out

 the desired leaving water

temperature

 (main + additional).

Leaving water
temperature home
pages (main +
additional)

Adjust/overrule

 

the 

leaving 

water

temperature

 (main).

Adjust

  the  leaving  water 

temperature

(additional).

Select

 which leaving water temperature

schedule

 (main + additional) you want to

use.

Menu structure

Program 

leaving water temperature

schedule

 (main + additional).

Define preset values

 that are used by the

leaving water temperature schedule (main).

See also:

"Using  the  leaving  water  temperature  home  pages  (main  +
additional)" on page 9

"4.7 Preset values and schedules" on page 16

External room thermostat control

External  room  thermostat  control  means  that  you  control  the
following:

▪ Room temperature on the external thermostat control

▪ Leaving water temperature on the user interface (Daikin)

To control the leaving water temperature, you can do the following:

You can…

Location

Read out

 the desired leaving water

temperature

.

Leaving water
temperature home
pages (main +
additional)

Adjust 

the desired leaving water

temperature.

Only change this if the desired room
temperature cannot be reached.

See also: 

"Using the leaving water temperature home pages (main +

additional)" on page 9

.

Using the room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to

"4.6.6 Configuring user profile and home pages" on page 15

.

User profile = Basic

User profile = Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

Example: Temporarily overruling the schedule AND changing
the mode to preset value

You have configured the following settings:

Settings

Description

Preset values

Comfort (heating) =
20°C

Desired temperature when
you are at home.

Eco (heating) = 18°C Desired temperature:

▪ When you are away

▪ During the night

Schedule

07:00 Comfort

You are at home.

Desired temperature =
preset value (Comfort
(heating)).

09:00 Eco

You are away.

Desired temperature =
preset value (Eco
(heating)).

17:00 Comfort

You are at home.

Desired temperature =
preset value (Comfort
(heating)).

19:00 21°C

You are at home and want
it to be a little warmer.

Desired temperature =
custom temperature.

23:00 Eco

Desired temperature =
preset value (Eco
(heating)).

Overrule period
(Temperature
lock)

2 hours

If you temporarily overrule
the schedule by a preset
value, after 2 hours the
schedule will be used
again.

If user profile = Basic, then you can 

temporarily overrule

 the room

temperature schedule by pressing 

 or 

.

Summary of Contents for EHBH08CB

Page 1: ...uide Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB E...

Page 2: ...0 4 10 3 Domestic hot water control A 4 20 4 10 4 Contact helpdesk number 6 3 2 20 5 Energy saving tips 20 6 Maintenance and service 21 6 1 Overview Maintenance and service 21 6 2 To find the contact...

Page 3: ...ngs that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Docu...

Page 4: ...of menu structure Installer settings table Overview of installer settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home...

Page 5: ...ble Room temperature Room Main leaving water temperature LWT main Additional leaving water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is di...

Page 6: ...hich space operation mode is currently used 1 Go to one of the following the home pages Room temperature home page Room Main leaving water temperature home page LWT main Additional leaving water tempe...

Page 7: ...et point on the home page No Linked by their preset values You can set the preset values in the menu structure Room thermostat control Room thermostat control means that you control the following Room...

Page 8: ...either a basic or a detailed home page To set the user profile refer to 4 6 6 Configuring user profile and home pages on page 15 User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual t...

Page 9: ...ermanent hours 2 4 6 8 Usage example You have a party If you are in the following situation You are using the following room temperature schedule 17 00 preset value Comfort 20 C 23 00 preset value Eco...

Page 10: ...e successful and the applicable warning AH will be generated INFORMATION In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping following...

Page 11: ...a preset value example Storage eco 50 C Hot water is available again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day th...

Page 12: ...of the DHW tank Heat up to the preset value Eco example 55 C and sufficient for 2 persons at 14 00 This evening you need hot water for 3 persons Then you can do the following 1 Go to the DHW tank tem...

Page 13: ...quiet Under all circumstances performance will be reduced Level 2 Medium quiet Under all circumstances reduced performance is possible Level 3 Least quiet At colder ambient conditions reduced perform...

Page 14: ...oliday Holiday mode 2 Select Home 3 Configure the holiday mode settings when you stay at home 4 Activate the holiday mode Possible holiday mode settings when you stay at home Setting Description From...

Page 15: ...onfigure time and date Prerequisite You switched the permission level to Advanced end user 1 Go to 1 Set time date INFORMATION Switch to Adv end user to change daylight saving time and 12 24h notation...

Page 16: ...o 7 4 User settings Preset values 2 Select for which control you want to define a preset value Example Room temperature 3 Select a preset value and press Example Comfort heating 4 Select a temperature...

Page 17: ...ft DayShift and LateShift 2 Select the schedule that you currently want to use 4 7 3 Schedules Example INFORMATION The procedures to program other schedules are similar In this example Room temperatur...

Page 18: ...n the outdoor temperature To select the setpoint mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prer...

Page 19: ...vel Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor uni...

Page 20: ...A 3 1 1 7 Emitter type 1 Slow 4 10 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling...

Page 21: ...ser interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure indicated on the manometer is above 1 bar Refrigerant This product contains fluorinated green...

Page 22: ...backup heater takes over the heat load electricity consumption will be considerably higher 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit...

Page 23: ......

Page 24: ...4P384964 1 2015 01 Copyright 2015 Daikin...

Reviews: