4 Operation

User reference guide

10

EHBH/X04~16CB + EHVH/X04~16S18+26CB

Daikin Altherma – Low temperature split

4P384964-1 – 2015.01

Additional zone:

User profile = Basic

User profile = Detailed

15:20

45°C

Desired temperature

LWT add

Mon

15:20

45°C

17:30

Mon

Mon

LWT add

Desired temperature

To read out the desired leaving water temperature (main +
additional)

Go to the leaving water temperature home page (LWT main or LWT
add).

To adjust/overrule the leaving water temperature (main)(NOT
linked to room thermostat control)

INFORMATION

Adjusting  the  leaving  water  temperature  is  permanent
unless  the  leaving  water  temperature  is  according  to  a
schedule. In that case the overruling is valid until the next
scheduled action.

1

Go to [7.4.2]: 

 > User settings > Preset values > LWT main.

2

Press 

 or 

 to adjust/overrule. 

Example: 

35°C 37°C

To adjust the leaving water temperature (additional)

1

Go  to  the  additional  leaving  water  temperature  home  page
(LWT add).

2

Press 

 or 

 to adjust. 

Example: 

45°C 47°C

INFORMATION

In  case  of  weather  dependency,  an  offset  value  can  be
modified.

4.5

Domestic hot water control

4.5.1

About domestic hot water control

Depending  on  the  DHW  tank  mode  (installer  setting),  you  use  a
different domestic hot water control:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

CAUTION

The booster heater permission schedule is used to restrict
or  allow  booster  heater  operation  based  on  a  weekly
program.  Advice:  In  order  to  avoid  unsuccessful
disinfection  function,  at  least  allow  the  booster  heater  (by
the weekly program) for minimum 4 hours starting from the
scheduled  start-up  of  disinfection.  If  the  booster  heater  is
restricted  during  disinfection,  this  function  will  NOT  be
successful  and  the  applicable  warning  AH  will  be
generated.

INFORMATION

In  case  of  error  code  AH  and  no  interruption  of  the
disinfection  function  occurred  due  to  domestic  hot  water
tapping, following actions are recommended:

▪ When  the  Domestic  hot  water  >  Type  >  Reheat  or

Reheat  +  sched.  is  selected,  it  is  recommended  to
program the start-up of the disinfection function at least
4  hours  later  than  the  last  expected  large  hot  water
tapping.  This  start-up  can  be  set  by  installer  settings
(disinfection function).

▪ When the Domestic hot water > Type > Scheduled only

is  selected,  it  is  recommended  to  program  a  Storage
eco  3  hours  before  the  scheduled  start-up  of  the
disinfection function to preheat the tank.

To determine which DHW tank mode you are using (method 1)

Check the installer settings table filled in by the installer.

To determine which DHW tank mode you are using (method 2)

Prerequisite: 

User profile = Detailed.

1

Go to the DHW tank temperature home page (Tank).

2

Check which icons are displayed:

If… is displayed

Then the DHW tank mode =…

Reheat mode

Scheduled mode

 

Sch reheat mode

4.5.2

Reheat mode

In  reheat  mode  ( ),the  DHW  tank  continuously  heats  up  to  the
temperature  shown  on  the  DHW  tank  temperature  home  page
(example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

DHW tank temperature

t

Time

INFORMATION

There  is  a  risk  of  space  heating  (cooling)  capacity
shortage/comfort problem (in case of frequent domestic hot
water  operation,  frequent  and  long  space  heating/cooling
interruption  will  happen)  when  selecting  [6‑0D]=0  ([A.4.1]
Domestic  hot  water  Type=Reheat  only)  in  case  of  a
domestic hot water tank without an internal booster heater.

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating/cooling  function
is regularly interrupted.

Summary of Contents for EHBH08CB

Page 1: ...uide Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB E...

Page 2: ...0 4 10 3 Domestic hot water control A 4 20 4 10 4 Contact helpdesk number 6 3 2 20 5 Energy saving tips 20 6 Maintenance and service 21 6 1 Overview Maintenance and service 21 6 2 To find the contact...

Page 3: ...ngs that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Docu...

Page 4: ...of menu structure Installer settings table Overview of installer settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home...

Page 5: ...ble Room temperature Room Main leaving water temperature LWT main Additional leaving water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is di...

Page 6: ...hich space operation mode is currently used 1 Go to one of the following the home pages Room temperature home page Room Main leaving water temperature home page LWT main Additional leaving water tempe...

Page 7: ...et point on the home page No Linked by their preset values You can set the preset values in the menu structure Room thermostat control Room thermostat control means that you control the following Room...

Page 8: ...either a basic or a detailed home page To set the user profile refer to 4 6 6 Configuring user profile and home pages on page 15 User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual t...

Page 9: ...ermanent hours 2 4 6 8 Usage example You have a party If you are in the following situation You are using the following room temperature schedule 17 00 preset value Comfort 20 C 23 00 preset value Eco...

Page 10: ...e successful and the applicable warning AH will be generated INFORMATION In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping following...

Page 11: ...a preset value example Storage eco 50 C Hot water is available again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day th...

Page 12: ...of the DHW tank Heat up to the preset value Eco example 55 C and sufficient for 2 persons at 14 00 This evening you need hot water for 3 persons Then you can do the following 1 Go to the DHW tank tem...

Page 13: ...quiet Under all circumstances performance will be reduced Level 2 Medium quiet Under all circumstances reduced performance is possible Level 3 Least quiet At colder ambient conditions reduced perform...

Page 14: ...oliday Holiday mode 2 Select Home 3 Configure the holiday mode settings when you stay at home 4 Activate the holiday mode Possible holiday mode settings when you stay at home Setting Description From...

Page 15: ...onfigure time and date Prerequisite You switched the permission level to Advanced end user 1 Go to 1 Set time date INFORMATION Switch to Adv end user to change daylight saving time and 12 24h notation...

Page 16: ...o 7 4 User settings Preset values 2 Select for which control you want to define a preset value Example Room temperature 3 Select a preset value and press Example Comfort heating 4 Select a temperature...

Page 17: ...ft DayShift and LateShift 2 Select the schedule that you currently want to use 4 7 3 Schedules Example INFORMATION The procedures to program other schedules are similar In this example Room temperatur...

Page 18: ...n the outdoor temperature To select the setpoint mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prer...

Page 19: ...vel Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor uni...

Page 20: ...A 3 1 1 7 Emitter type 1 Slow 4 10 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling...

Page 21: ...ser interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure indicated on the manometer is above 1 bar Refrigerant This product contains fluorinated green...

Page 22: ...backup heater takes over the heat load electricity consumption will be considerably higher 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit...

Page 23: ......

Page 24: ...4P384964 1 2015 01 Copyright 2015 Daikin...