background image

4 Operation

User reference guide

5

EHBH/X04~16CB + EHVH/X04~16S18+26CB
Daikin Altherma – Low temperature split
4P384964-1 – 2015.01

4.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Child lock mode and/or function lock mode is active.

An external heat source is active. 

Example: 

Gas

burner.

The disinfection mode is active.

A malfunction occured. Press 

 to display more

information about the malfunction.

Weather-dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

Emergency operation is active.

4.3

Basic usage

4.3.1

Using home pages

About home pages

You  can  use  the  home  pages  to  read  out  and  change  settings  that
are  meant  for  daily  usage.  What  you  can  see  and  do  on  the  home
pages  is  described  where  applicable.  Depending  on  your  system
layout, the following home pages may be possible:

▪ Room temperature (Room)

▪ Main leaving water temperature (LWT main)

▪ Additional leaving water temperature (LWT add)

▪ DHW tank temperature (Tank)

To go to a home page

1

Press 

.

Result: 

One of the home pages is displayed.

2

Press 

 again to display the next home page (if any).

4.3.2

Using the menu structure

About the menu structure

You  can  use  the  menu  structure  to  read  out  and  configure  settings
that are NOT meant for daily usage. What you can see and do in the
menu  structure  is  described  where  applicable.  For  an  overview  of
the  menu  structure,  see 

"4.9  Menu  structure:  Overview"  on

page 19

.

To go to the menu structure

1

From a home page, press 

.

Result: 

The menu structure is displayed.

1
>
>
>
>

Select

Scroll

Set time/date
Holiday
Quiet mode
Operation mode
Select schedules
Information

Auto

Heating

To navigate in the menu structure

Use 

 and 

.

4.3.3

Turning ON/OFF controls

About turning ON/OFF controls

Before you can control…

You have to turn ON…

Room temperature

Room temperature control
(Room)

Main (+ additional) leaving water
temperature

Main (+ additional) leaving water
temperature control (LWT main
and LWT add)

Main and additional leaving
water temperature control are
always turned ON or OFF
together.

DHW tank temperature

Domestic hot water control
(Tank)

If you turn ON…

Then…

Room temperature control

Main (+ additional) leaving water
temperature control is
automatically turned ON.

Main (+ additional) leaving water
temperature control

Room temperature control is
NOT automatically turned ON.

If you turn OFF…

Then…

Room temperature control

Main (+ additional) leaving water
temperature control is NOT
automatically turned OFF.

Main (+ additional) leaving water
temperature control

Room temperature control is
automatically turned OFF.

To check if a control is turned ON or OFF

1

Go  to  the  home  page  of  the  control. 

Example: 

Room

temperature home page (Room).

2

Check  if  the  LED  is  ON  or  OFF. 

Note: 

If  the  control  is  turned

OFF, OFF is also displayed on the screen. 

Summary of Contents for EHBH08CB

Page 1: ...uide Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB E...

Page 2: ...0 4 10 3 Domestic hot water control A 4 20 4 10 4 Contact helpdesk number 6 3 2 20 5 Energy saving tips 20 6 Maintenance and service 21 6 1 Overview Maintenance and service 21 6 2 To find the contact...

Page 3: ...ngs that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Docu...

Page 4: ...of menu structure Installer settings table Overview of installer settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home...

Page 5: ...ble Room temperature Room Main leaving water temperature LWT main Additional leaving water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is di...

Page 6: ...hich space operation mode is currently used 1 Go to one of the following the home pages Room temperature home page Room Main leaving water temperature home page LWT main Additional leaving water tempe...

Page 7: ...et point on the home page No Linked by their preset values You can set the preset values in the menu structure Room thermostat control Room thermostat control means that you control the following Room...

Page 8: ...either a basic or a detailed home page To set the user profile refer to 4 6 6 Configuring user profile and home pages on page 15 User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual t...

Page 9: ...ermanent hours 2 4 6 8 Usage example You have a party If you are in the following situation You are using the following room temperature schedule 17 00 preset value Comfort 20 C 23 00 preset value Eco...

Page 10: ...e successful and the applicable warning AH will be generated INFORMATION In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping following...

Page 11: ...a preset value example Storage eco 50 C Hot water is available again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day th...

Page 12: ...of the DHW tank Heat up to the preset value Eco example 55 C and sufficient for 2 persons at 14 00 This evening you need hot water for 3 persons Then you can do the following 1 Go to the DHW tank tem...

Page 13: ...quiet Under all circumstances performance will be reduced Level 2 Medium quiet Under all circumstances reduced performance is possible Level 3 Least quiet At colder ambient conditions reduced perform...

Page 14: ...oliday Holiday mode 2 Select Home 3 Configure the holiday mode settings when you stay at home 4 Activate the holiday mode Possible holiday mode settings when you stay at home Setting Description From...

Page 15: ...onfigure time and date Prerequisite You switched the permission level to Advanced end user 1 Go to 1 Set time date INFORMATION Switch to Adv end user to change daylight saving time and 12 24h notation...

Page 16: ...o 7 4 User settings Preset values 2 Select for which control you want to define a preset value Example Room temperature 3 Select a preset value and press Example Comfort heating 4 Select a temperature...

Page 17: ...ft DayShift and LateShift 2 Select the schedule that you currently want to use 4 7 3 Schedules Example INFORMATION The procedures to program other schedules are similar In this example Room temperatur...

Page 18: ...n the outdoor temperature To select the setpoint mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prer...

Page 19: ...vel Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor uni...

Page 20: ...A 3 1 1 7 Emitter type 1 Slow 4 10 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling...

Page 21: ...ser interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure indicated on the manometer is above 1 bar Refrigerant This product contains fluorinated green...

Page 22: ...backup heater takes over the heat load electricity consumption will be considerably higher 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit...

Page 23: ......

Page 24: ...4P384964 1 2015 01 Copyright 2015 Daikin...