background image

4 Operation

User reference guide

6

EHBH/X04~16CB + EHVH/X04~16S18+26CB

Daikin Altherma – Low temperature split

4P384964-1 – 2015.01

To turn ON or OFF the room temperature control

1

Go to the room temperature home page (Room).

2

Press 

.

To turn ON or OFF the leaving water temperature (main +
additional) control

1

Go to one of the following the home pages:

▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)

2

Press 

.

To turn ON or OFF the domestic hot water control

1

Go to the DHW tank temperature home page (Tank).

2

Press 

.

4.4

Space heating/cooling control

4.4.1

About space heating/cooling control

Controlling  space  heating/cooling  typically  consists  of  the  following
stages:

1

Setting the space operation mode

2

Controlling the temperature

4.4.2

Setting the space operation mode

About space operation modes

Depending  on  your  heat  pump  model,  you  have  to  tell  the  system
which space operation mode to use: heating or cooling.

If a… heat pump model

is installed

Then…

Heating/cooling

The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.

Heating only

The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.

To  tell  the  system  which  space  operation  to  use,  you  can  do  the
following:

You can…

Location

Check

 which space operation mode is

currently used

.

Home pages:

▪ Room temperature

▪ Leaving 

water

temperature  (main
+ additional)

Set

 the space operation 

mode

.

Menu structure

Restrict

 when 

automatic changeover

 is

possible.

To determine if a heating/cooling heat pump model is installed

1

Press 

 to go to the menu structure.

2

Check  if  [4]  Operation  mode  is  listed.  If  so,  a  heating/cooling
heat pump model is installed.

To check which space operation mode is currently used

1

Go to one of the following the home pages:

▪ Room temperature home page (Room)
▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)

2

Check the status icon:

If you see…

Then…

Operation mode = heating.

Unit is NOT heating up your space.
However, the DHW tank can be
heating up.

Operation mode = heating.

Unit is heating up your space at this
moment.

Operation mode = cooling.

Unit is NOT cooling down your space.
However, the DHW tank can be
heating up.

Operation mode = cooling.

Unit is cooling down your space at this
moment.

To set the space operation mode

1

Go to [4]: 

 > Operation mode.

2

Select one of the following options and press 

:

If you select…

Then the space operation mode is…

Heating

Always heating mode.

Cooling

Always cooling mode.

Automatic

Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
taking monthly restrictions into
account.

Note: 

Automatic changeover is only

possible under certain conditions.

To restrict automatic changeover operation mode

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

Prerequisite: 

You switched the space operation mode to automatic.

1

Go to [7.5]: 

 > User settings > Allowed operation mode.

2

Select a month and press 

.

3

Select Heating only, Cooling only or Heating/Cooling, and press

.

Typical automatic changeover restrictions

When

Restriction

During cold season.

Example: 

October, November,

December, January, February and March.

Heating only

During warm season.

Example: 

June, July and August.

Cooling only

In-between.

Example: 

April, May and September.

Heating/Cooling

4.4.3

Controlling the temperature

About controlling the temperature

Depending on the system layout and installer configuration, you use
a different temperature control:

▪ Room  thermostat  control  (linked  or  NOT  linked  to  leaving  water

temperature)

▪ Leaving water temperature control

▪ External room thermostat control

Summary of Contents for EHBH08CB

Page 1: ...uide Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB EHVH04S18CB EHVH08S18CB EHVH08S26CB EHVH11S18CB EHVH11S26CB EHVH16S18CB EHVH16S26CB E...

Page 2: ...0 4 10 3 Domestic hot water control A 4 20 4 10 4 Contact helpdesk number 6 3 2 20 5 Energy saving tips 20 6 Maintenance and service 21 6 1 Overview Maintenance and service 21 6 2 To find the contact...

Page 3: ...ngs that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Docu...

Page 4: ...of menu structure Installer settings table Overview of installer settings 4 2 The user interface at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home...

Page 5: ...ble Room temperature Room Main leaving water temperature LWT main Additional leaving water temperature LWT add DHW tank temperature Tank To go to a home page 1 Press Result One of the home pages is di...

Page 6: ...hich space operation mode is currently used 1 Go to one of the following the home pages Room temperature home page Room Main leaving water temperature home page LWT main Additional leaving water tempe...

Page 7: ...et point on the home page No Linked by their preset values You can set the preset values in the menu structure Room thermostat control Room thermostat control means that you control the following Room...

Page 8: ...either a basic or a detailed home page To set the user profile refer to 4 6 6 Configuring user profile and home pages on page 15 User profile Basic User profile Detailed 15 20 20 0 C Mon Room Actual t...

Page 9: ...ermanent hours 2 4 6 8 Usage example You have a party If you are in the following situation You are using the following room temperature schedule 17 00 preset value Comfort 20 C 23 00 preset value Eco...

Page 10: ...e successful and the applicable warning AH will be generated INFORMATION In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping following...

Page 11: ...a preset value example Storage eco 50 C Hot water is available again During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again At 00 00 the next day th...

Page 12: ...of the DHW tank Heat up to the preset value Eco example 55 C and sufficient for 2 persons at 14 00 This evening you need hot water for 3 persons Then you can do the following 1 Go to the DHW tank tem...

Page 13: ...quiet Under all circumstances performance will be reduced Level 2 Medium quiet Under all circumstances reduced performance is possible Level 3 Least quiet At colder ambient conditions reduced perform...

Page 14: ...oliday Holiday mode 2 Select Home 3 Configure the holiday mode settings when you stay at home 4 Activate the holiday mode Possible holiday mode settings when you stay at home Setting Description From...

Page 15: ...onfigure time and date Prerequisite You switched the permission level to Advanced end user 1 Go to 1 Set time date INFORMATION Switch to Adv end user to change daylight saving time and 12 24h notation...

Page 16: ...o 7 4 User settings Preset values 2 Select for which control you want to define a preset value Example Room temperature 3 Select a preset value and press Example Comfort heating 4 Select a temperature...

Page 17: ...ft DayShift and LateShift 2 Select the schedule that you currently want to use 4 7 3 Schedules Example INFORMATION The procedures to program other schedules are similar In this example Room temperatur...

Page 18: ...n the outdoor temperature To select the setpoint mode see the installer reference guide To set the parameters for the weather dependent curve see below 4 8 1 To set the weather dependent settings Prer...

Page 19: ...vel Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor uni...

Page 20: ...A 3 1 1 7 Emitter type 1 Slow 4 10 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Maximum setpoint Depends on model INFORMATION There is a risk of space heating cooling...

Page 21: ...ser interface clean with a soft damp cloth Do NOT use any detergents Regularly check if the water pressure indicated on the manometer is above 1 bar Refrigerant This product contains fluorinated green...

Page 22: ...backup heater takes over the heat load electricity consumption will be considerably higher 8 Relocation 8 1 Overview Relocation If you want to relocate parts of your system user interface indoor unit...

Page 23: ......

Page 24: ...4P384964 1 2015 01 Copyright 2015 Daikin...

Reviews: