4 Operation
User reference guide
18
EHBH/X04~16CB + EHVH/X04~16S18+26CB
Daikin Altherma – Low temperature split
4P384964-1 – 2015.01
INFORMATION
The predefined schedules are applicable for both heating
and cooling operation.
4.7.5
Predefined schedules: Leaving water
temperature (additional)
: Additional zone = On
: Additional zone = OFF
Predefined 1
Mon - Fri
07:00 09:00
17:00
23:00
Sat - Sun
08:00
23:00
Predefined 2
Mon - Fri
07:00 09:00
17:00
12:00
23:00
14:00
Sat - Sun
08:00
23:00
Predefined 3
Mon - Sun
08:00
23:00
INFORMATION
The predefined schedules are applicable for both heating
and cooling operation.
4.7.6
Predefined schedules: DHW tank
temperature
a
: Start production of domestic hot water. Desired DHW tank
temperature = Preset value (Storage comfort)
b
: Start production of domestic hot water. Desired DHW tank
temperature = Preset value (Storage eco)
Predefined 1
Mon - Sun
a
b
:00
Predefined 2
Mon - Sun
a
b
:00
:00
Predefined 3
Mon - Fri
a
b
:00
Sat - Sun
a
b
:00
:00
4.8
Weather dependent operation
In space heating/cooling control, the leaving water temperature
setpoint mode can be:
▪ Fixed
▪ Weather-dependent (the leaving water temperature is determined
automatically depending on the outdoor temperature)
To select the setpoint mode, see the installer reference guide.
To set the parameters for the weather-dependent curve, see below.
4.8.1
To set the weather dependent settings
Prerequisite:
You switched the permission level to Advanced end
user.
1
Go to [7.7]:
> User settings > Set weather dependent.
2
For main leaving water temperature zone [7.7.1], modify with
,
,
,
, and confirm with
.
3
If applicable, for additional leaving water temperature zone
[7.7.2], modify with
,
,
,
, and confirm with
.
Set weather-dependent heating/Set weather-dependent cooling
d
c
Ta
Tt
a
b
T
t
Target leaving water temperature
T
a
Outdoor temperature
a
Low outdoor ambient temperature
b
High outdoor ambient temperature
c
Desired leaving water temperature when the outdoor
temperature equals or drops below the low ambient
temperature.
Note:
in heating, this value should be higher
than (d) as for low outdoor temperatures warmer water is
required. In cooling, this value should be higher than (d) as
for low outdoor temperatures less cold water suffices
d
Desired leaving water temperature when the outdoor
temperature equals or rises above the high ambient
temperature.
Note:
in heating, this value should be lower
than (c) as for high outdoor temperatures less warm water
is required. In cooling, this value should be lower than (c)
as for high outdoor temperatures colder water is required.