Wiring Diagram

CAP

BK (HI) 

AUXILIARY 

PROPERLY POLARIZED AND GROUNDED.

SERVICING.WIRING TO UNIT MUST BE

WARNING:DISCONNECT POWER BEFORE 

XFMR

BK

115V

24V

BR

LIMITS

 WH (N) 

RD (LOW) 

OR(MED LOW)

BL (MED) 

BLOWER

CICULATOR

24V THERMOSTAT CONNECTIONS

RO2 (11)

LIMIT

GND (8)

HUMIDIFIER

XFMR (6)

GND

G

C

W

Y

TO

MICRO

R

MVL (2)

MVC (9)

 AUXILIARY

LIMIT CONTROLS

PS (10)

PSO (4)
HLI (7)

HLO (1)

CONTROL MODULE

INTEGRATED 

NO

SWITCH

PRESSURE

ID BLOWER

VALVE

M1

GAS

C2

C

AUTO RESET

PRIMARY

MANUAL RESET ROLLOUT

LIMIT CONTROL(S)

115 VAC

FLAME SENSOR

FP

XFMR-H

XFMR (3)

RO1 (5)

24 VAC

HOT SURFACE

IGNITER

INTEGRATED CONTROL MODULE

BR

BR

COOL-H

IGN

IND

ID

BLWR

CIRCULATOR

HEAT-H

BLWR

TRANSFORMER

40 VA

CONTROL

XFMR-N

INTEGRATED CONTROL MODULE

CIR-N

0140F00662  REV. A

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

ON SOME MODELS

HUMIDIFIER

24 VAC

INDUCED DRAFT

C. USE COPPER CONDUCTORS ONLY.

BLOWER COMPARTMENT

BURNER COMPARTMENT

   REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

   CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART)

   REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE

4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION

INTEGRATED CONTROL

       INTERNAL TO

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

BLOWER

PRIMARY LIMIT

WH

GR

BK

IGNITER

SURFACE

HOT

PU

RD

15 PIN PLUG

C

NO

SWITCH

PRESSURE 

BR

SENSOR

FLAME

BK

WH

ROLLOUT LIMITS

   RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)

   7 FLASHES = LOW FLAME SIGNAL

   5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

   4 FLASHES = OPEN HIGH LIMIT

   3 FLASHES = PRESSURE SWITCH STUCK OPEN

   2 FLASHES = PRESSURE SWITCH STUCK CLOSED

   STEADY ON = NORMAL OPERATION

OFF       = CONTROL FAILURE

5

   1 FLASH   =

0

1

2

3

4

PU

   6 FLASHES =  OPEN ROLLOUT OR OPEN FUSE

COLOR CODES:

PU PURPLE

OR  ORANGE

YL  YELLOW

6

7

8

BK BLACK

GR GREEN

BR BROWN

PK PINK

RD  RED

GY GRAY

BL BLUE

WH  WHITE

PU

   RATING OF AT LEAST 105

NOTES:

OVERCURRENT PROTECTION DEVICE

JUNCTION BOX

MUST BE

WARNING: 

SWITCH

WIRING TO UNIT

BEFORE SERVICING.

DISCONNECT POWER

LINE-H

DOOR

AND GROUNDED.

POLARIZED

PROPERLY

L

GND

LINE-N

DISCONNECT

N

SWITCH (TEMP.)

FIELD SPLICE

SWITCH (PRESS.)

PROT. DEVICE

 OVERCURRENT

EQUIPMENT GND

TERMINAL

JUNCTION

HI VOLTAGE FIELD

HI VOLTAGE (115V)

LOW VOLTAGE FIELD

LOW VOLTAGE (24V)

PLUG CONNECTION

IGNITER

FIELD GND

IND-N

IGN-N

JUNCTION

BOX

OVERCURRENT PROTECTION

POWER SUPPLY WITH

TO 115 VAC/ 1/60HZ

GND

LINE-N

LINE H

DEVICE

DOOR SWITCH

WH

BK

SWITCH LOCATED IN BLOWER 

COMPARTMENT ON SOME MODELS

RD

RD

BL

PU

YL

OR

BR

(SINGLE CONTROL ON SOME MODELS)

(SINGLE CONTROL ON SOME MODELS)

DIAGNOSTIC

LED

LO HEAT-H

PARK

SEE NOTE 6

COOL-H

HI HEAT-H

8

7

9

6

5

4

12

C

G

R

W

Y

5 MIN

2 STG

100 SEC

1 STG

AUTO
150 SEC

MODE

2ND STG DLY

HT OFF DLY

2

1

EAC-H

LINE-H

XFMR-H

LINE NEUTRAL

FS

0

1

1

1

3

2

1

CONTROL MODULE

INTEGRATED

FUSE

PM

1

C

I

H

2

3

2 STAGE

GAS VALVE

(HONEY WELL)

WH

24 VAC

HUMIDIFIER

RD

HI

MVH (12)

HI

LO

HEAT-H

AIR CLEANER

ELECTRONIC

EAC-N

EAC-H

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH

   FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS).

WH

BL

BR

WH

BL

BK

BK

YL

YL

RD

YL

YL

PU

OR

WH

WH

WH

WH

YL

BL

RD

C

   8 FLASHES = CHECK IGNITER OR IMPROPER GROUND

6

www.daikincomfort.com

SS-DM80HS

SS-DM80HS

www.daikincomfort.com

7

Wirin

is 

sub

ject 

to 

chan

ge. 

Alw

ay

re

fer 

to 

the 

wirin

diagr

am 

on 

th

unit 

for 

the 

mos

up-t

o-da

te 

wiring.

 

W

arning

High V

olt

age:

 

Disc

onn

ect 

all 

po

w

er 

be

for

ser

vicin

or 

in

st

allin

th

is 

unit. 

Mu

lti

ple 

po

w

er

 

 

sou

rces 

ma

be 

pr

esen

t. 

Failu

re 

to 

do 

so 

ma

cause 

pr

op

erty 

damag

e, 

per

son

al 

inju

ry

, or 

dea

th

.

Summary of Contents for DM80HS0403A

Page 1: ...quired in California or Quebec Standard Features Cabinet Features Stainless steel dual diameter tubular heat exchanger Two stage convertible gas valve auto matically adjusts to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Quiet four speed direct drive circulating blower motor Self diagnostic control board with constant memory fault code Color coded low voltage...

Page 2: ...97 97 98 AFUE 92 92 AFUE N Natural Gas 96 96 AFUE 80 80 AFUE X Low NOx Gas Valve Cabinet Width M Modulating H Convertible Two Stage A 14 C 21 V Two Stage S Single Stage B 17 D 24 Motor C Variable Speed ECM ComfortNet Maximum CFM E High Efficiency S Single Speed 2 800 CFM 3 1200 CFM MBTU h 4 1600 CFM 040 40 000 BTU h 100 100 000 BTU h 5 2000 CFM 060 60 000 BTU h 120 120 000 BTU h 080 80 000 BTU h 1...

Page 3: ...6 107 114 118 132 132 Natural Gas BTU h for altitudes above from 0 to 5 500 above sea level reduce input rating 4 for each 1 000 above 5 500 altitude Low fire rate is 75 of high fire rate DOE AFUE based upon Isolated Combustion System ICS Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada Nation...

Page 4: ...m Clearances to Combustible Materials Sides Rear Front Bottom Vent Top SW B 1 0 3 C 6 1 1 C If placed on combustible floor the floor MUST be wood ONLY Notes For servicing or cleaning a 24 front clearance is recommended Unit connections electrical flue and drain may necessitate greater clearances than the minimum clearances listed above In all cases accessibility clearance must take precedence over...

Page 5: ... Med Lo 3 5 1 615 37 1 592 37 1 556 38 1 516 39 1 470 40 1 405 1 346 1 235 Low 3 1 290 46 1 285 46 1 265 47 1 235 48 1 214 49 1 174 1 044 904 DM80HS 1005C A High 5 2 323 2 225 2 120 35 2 040 36 1 974 38 1 801 1 688 1 577 Med 4 1 858 40 1 847 40 1 799 41 1 744 42 1 674 44 1 577 1 493 1 399 Med Lo 3 5 1 596 46 1 587 47 1 571 47 1 552 48 1 493 50 1 397 1 326 1 217 Low 3 1 291 57 1 272 58 1 261 59 1 2...

Page 6: ...ERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Formulas BTU h Output CFM x 1 08 x Rise Rise BTU H Output CFM x 1 08 BTU Output Vs Temperature Rise Chart Output BTU h x 1 000 6 www daikincomfort com SS DM80HS ...

Page 7: ...LIMIT 3 FLASHES PRESSURE SWITCH STUCK OPEN 2 FLASHES PRESSURE SWITCH STUCK CLOSED STEADY ON NORMAL OPERATION OFF CONTROL FAILURE 5 1 FLASH 0 1 2 3 4 PU 6 FLASHES OPEN ROLLOUT OR OPEN FUSE COLOR CODES PU PURPLE OR ORANGE YL YELLOW 6 7 8 BK BLACK GR GREEN BR BROWN PK PINK RD RED GY GRAY BL BLUE WH WHITE PU RATING OF AT LEAST 105 NOTES OVERCURRENT PROTECTION DEVICE JUNCTION BOX MUST BE WARNING SWITCH...

Page 8: ...005C DM80 HS1205D DM80 HS1405D Filter Size in2 1 16 x 25 Side or 1 14 x 24 Bottom 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x 25 Bottom 2 16 x 25 Side or 1 24 x 24 Bottom Note Other size filters of equal or greater surface area may be used filters may also be centrally located Use 2 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is conn...