DM80HS
0403A*A
DM80HS
0603A*A
DM80HS
0604B*A
DM80HS
0803B*A
DM80HS
0804B*A
DM80HS
0805C*A
DM80HS
1005C*A
DM80HS
1205D*A
DM80HS
1405D*A
Heating Capacity
Input¹
40,000
60,000
60,000
80,000
80,000
80,000
100,000
120,000
140,000
Natural Gas Output¹
32,000
48,000
48,000
64,000
64,000
64,000
80,000
96,000
112,000
LP Gas Output¹
32,000
48,000
48,000
64,000
64,000
64,000
80,000
96,000
96,000
AFUE²
80
80
80
80
80
80
80
80
80
Available AC @ 0.5” ESP
3
3
4
3
4
5
5
5
5
Temperature Rise Range (°F)
25 - 55
20 - 50
20 - 50
35 - 65
35 - 65
35 - 65
35 - 65
40 - 70
40 - 70
Circulator Blower
Size (D x W)
10” x 6”
10” x 6”
10” x 8”
10” x 8”
10” x 8”
10” x 10”
10” x 10”
11” x 10”
11” x 10”
Horsepower @1075 RPM
⅓
⅓
½
⅓
½
½
½
¾
¾
Available Blower Speeds
4
4
4
4
4
4
4
4
4
Vent Diameter³
4"
4"
4"
4"
4"
4"
4"
4"
4"
No. of Burners
2
3
3
4
4
4
5
6
6
Electrical Data
Min. Circuit Ampacity
4
8.1
8.1
12.5
8.1
12.5
12.5
12.5
14.7
14.7
Max. Overcurrent Device (amps)
5
15
15
15
15
15
15
15
15
15
Ship Weight (lbs)
86
90
98
106
107
114
118
132
132
¹
Natural Gas BTU/h; for altitudes above from 0’ to 5,500’ above sea level, reduce input rating 4% for each 1,000’ above 5,500’ altitude. Low-fire rate is 75% of high-fire rate.
²
DOE AFUE based upon Isolated Combustion System (ICS)
³
Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard
of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).
4
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs
will require larger wire sizes.
5
Refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½” FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
2
www.daikincomfort.com
SS-DM80HS
SS-DM80HS
www.daikincomfort.com
3
Product Specifications