background image

Airflow Data 

(CFM & Temperature Rise vs. External Static Pressure)

Model

Motor 

Speed

Tons 

AC¹ 

External Static Pressure, (Inches Water Column)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

CFM

CFM

DM80HS

0403A*A

High

3

1,521

 ---

1,466

 ---

1,414

 ---

1,373

 ---

1,298

 ---

1,243

1,164

1,075

Med

2.5

1,160

26

1,160

26

1,132

26

1,121

26

1,082

27

1,042

997

925

Med-Lo

2

961

31

955

31

948

31

932

32

913

33

882

821

803

Low

1.5

781

38

785

38

781

38

773

38

761

32

745

716

668

DM80HS

0603A*A

High

3

1,422

31

1,352

33

1,307

34

1,197

37

1,157

38

1,092

1,075

983

Med

2.5

1,098

40

1,081

41

1,051

42

1,039

43

1,021

44

983

924

868

Med-Lo

2

919

48

913

49

892

50

847

----

829

----

818

792

728

Low

1.5

758

----

741

----

741

----

733

----

699

----

677

649

626

DM80HS

0604B*A

High

4

2,134

21

2,100

21

2,042

22

1,975

23

1,883

24

1,786

1,700

1,601

Med

3.5

1,668

27

1,663

27

1,656

27

1,645

27

1,616

28

1,549

1,492

1,391

Med-Lo

3

1,419

31

1,426

31

1,426

31

1,432

31

1,419

31

1,378

1,328

1,261

Low

2.5

1,134

39

1,145

39

1,166

38

1,171

38

1,160

38

1,144

1,111

1,071

DM80HS

0803B*A

High

3

1,607

37

1,572

38

1,547

39

1,498

40

1,448

41

1,390

1,302

1,222

Med

2.5

1,159

51

1,156

51

1,145

52

1,127

53

1,108

53

1,075

1,033

957

Med-Lo

2

938

63

916

65

916

65

900

----

889

----

865

829

785

Low

1.5

785

----

766

----

743

----

730

----

709

----

683

666

604

DM80HS

0804B*A

High

4

2,051

----

1,983

----

1,895

 ---

1,812

 ---

1,725

 ---

1,627

1,530

1,439

Med

3.5

1,736

 ---

1,708

35

1,652

36

1,611

37

1,540

38

1,475

1,394

1,307

Med-Lo

3

1,493

35

1,668

36

1,459

41

1,429

41

1,389

43

1,339

1,274

1,204

Low

2.5

1,200

49

1,185

50

1,180

50

1,173

51

1,158

51

1,125

1,125

1,080

DM80HS

0805C*A

High

5

2,290

----

2,229

----

2,155

----

2,047

----

1,960

----

1,837

1,712

1,584

Med

4

1,852

 ---

1,820

 ---

1,777

 ---

1,719

 ---

1,641

36

1,567

1,469

1,382

Med-Lo

3.5

1,615

37

1,592

37

1,556

38

1,516

39

1,470

40

1,405

1,346

1,235

Low

3

1,290

46

1,285

46

1,265

47

1,235

48

1,214

49

1,174

1,044

904

DM80HS

1005C*A

High

5

2,323

 ---

2,225

 ---

2,120

35

2,040

36

1,974

38

1,801

1,688

1,577

Med

4

1,858

40

1,847

40

1,799

41

1,744

42

1,674

44

1,577

1,493

1,399

Med-Lo

3.5

1,596

46

1,587

47

1,571

47

1,552

48

1,493

50

1,397

1,326

1,217

Low

3

1,291

57

1,272

58

1,261

59

1,257

59

1,205

61

1,168

1,118

1,060

DM80HS

1205D*A

High

5

2,469

 ---

2,389

 ---

2,300

 ---

2,223

40

2,131

42

2,027

1,902

1,786

Med

4

1,575

56

1,558

57

1,545

58

1,513

59

1,500

59

1,419

1,354

1,271

Med-Lo

3.5

1,402

63

1,380

64

1,343

66

1,319

67

1,296

69

1,245

1,183

1,106

Low

3

1,200

----

1,186

----

1,161

----

1,127

----

1,082

----

1,042

995

926

DM80HS

1405D*A

High

5

2,469

 ---

2,389

 ---

2,300

 ---

2,223

40

2,131

42

2,027

1,902

1,786

Med

4

1,575

56

1,558

57

1,545

58

1,513

59

1,500

59

1,419

1,354

1,271

Med-Lo

3.5

1,402

63

1,380

64

1,343

66

1,319

67

1,296

69

1,245

1,183

1,106

Low

3

1,200

----

1,186

----

1,161

----

1,127

----

1,082

----

1,042

995

926

Notes

• 

CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters 
are installed.

• 

All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed.

• 

For most jobs, 400 CFM per ton for cooling is desirable.

• 

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

• 

This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. 

• 

The dashed (----) areas indicate a temperature rise not recommended for this model.

• 

At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower.

4

www.daikincomfort.com

SS-DM80HS

SS-DM80HS

www.daikincomfort.com

5

Summary of Contents for DM80HS0403A

Page 1: ...quired in California or Quebec Standard Features Cabinet Features Stainless steel dual diameter tubular heat exchanger Two stage convertible gas valve auto matically adjusts to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Quiet four speed direct drive circulating blower motor Self diagnostic control board with constant memory fault code Color coded low voltage...

Page 2: ...97 97 98 AFUE 92 92 AFUE N Natural Gas 96 96 AFUE 80 80 AFUE X Low NOx Gas Valve Cabinet Width M Modulating H Convertible Two Stage A 14 C 21 V Two Stage S Single Stage B 17 D 24 Motor C Variable Speed ECM ComfortNet Maximum CFM E High Efficiency S Single Speed 2 800 CFM 3 1200 CFM MBTU h 4 1600 CFM 040 40 000 BTU h 100 100 000 BTU h 5 2000 CFM 060 60 000 BTU h 120 120 000 BTU h 080 80 000 BTU h 1...

Page 3: ...6 107 114 118 132 132 Natural Gas BTU h for altitudes above from 0 to 5 500 above sea level reduce input rating 4 for each 1 000 above 5 500 altitude Low fire rate is 75 of high fire rate DOE AFUE based upon Isolated Combustion System ICS Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada Nation...

Page 4: ...m Clearances to Combustible Materials Sides Rear Front Bottom Vent Top SW B 1 0 3 C 6 1 1 C If placed on combustible floor the floor MUST be wood ONLY Notes For servicing or cleaning a 24 front clearance is recommended Unit connections electrical flue and drain may necessitate greater clearances than the minimum clearances listed above In all cases accessibility clearance must take precedence over...

Page 5: ... Med Lo 3 5 1 615 37 1 592 37 1 556 38 1 516 39 1 470 40 1 405 1 346 1 235 Low 3 1 290 46 1 285 46 1 265 47 1 235 48 1 214 49 1 174 1 044 904 DM80HS 1005C A High 5 2 323 2 225 2 120 35 2 040 36 1 974 38 1 801 1 688 1 577 Med 4 1 858 40 1 847 40 1 799 41 1 744 42 1 674 44 1 577 1 493 1 399 Med Lo 3 5 1 596 46 1 587 47 1 571 47 1 552 48 1 493 50 1 397 1 326 1 217 Low 3 1 291 57 1 272 58 1 261 59 1 2...

Page 6: ...ERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Formulas BTU h Output CFM x 1 08 x Rise Rise BTU H Output CFM x 1 08 BTU Output Vs Temperature Rise Chart Output BTU h x 1 000 6 www daikincomfort com SS DM80HS ...

Page 7: ...LIMIT 3 FLASHES PRESSURE SWITCH STUCK OPEN 2 FLASHES PRESSURE SWITCH STUCK CLOSED STEADY ON NORMAL OPERATION OFF CONTROL FAILURE 5 1 FLASH 0 1 2 3 4 PU 6 FLASHES OPEN ROLLOUT OR OPEN FUSE COLOR CODES PU PURPLE OR ORANGE YL YELLOW 6 7 8 BK BLACK GR GREEN BR BROWN PK PINK RD RED GY GRAY BL BLUE WH WHITE PU RATING OF AT LEAST 105 NOTES OVERCURRENT PROTECTION DEVICE JUNCTION BOX MUST BE WARNING SWITCH...

Page 8: ...005C DM80 HS1205D DM80 HS1405D Filter Size in2 1 16 x 25 Side or 1 14 x 24 Bottom 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x 25 Bottom 2 16 x 25 Side or 1 24 x 24 Bottom Note Other size filters of equal or greater surface area may be used filters may also be centrally located Use 2 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is conn...

Reviews: