background image

2

English

Accessories

 

Choosing an Installation Site

Before choosing the installation site, obtain user approval.

1.

Indoor unit

• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,

2) both air inlet and air outlet have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote 

controller range,

8) the unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound),
9) install at the recommended height (1.8m),

10) no laundry equipment is located,

11) the appliance shall be stored so as to prevent mechanical damage from occurring.

2.

Wireless remote controller

• Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are properly received 

by the indoor unit (within 7m).

CAUTION

• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.  

In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. 

• Only qualified personnel can handle, fill, purge and dispose of the refrigerant.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage 

and insulate piping to prevent condensation. 

Improper drain piping may result in indoor water leakage and property damage. 

• Tighten the flare nut according to the specified method such as with a torque wrench. 

If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage. 

• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for 

commercial and household use by lay persons.

• Sound pressure level is less than 70 dB(A).

Mounting plate

1

Remote controller holder

1

Operation manual

1

Titanium apatite photocatalytic 
air-purifying filter

2

Dry battery AAA. LR03 

(alkaline)

2

Installation manual

1

Wireless remote controller

1

Indoor unit fixing screw 

(M4 × 12L)

2

Indoor unit

A

H

A

D

G

B

E

H

C

F

3PEN393185-7L.book  Page 2  Friday, February 26, 2016  7:49 AM

Summary of Contents for CTXM15M2V1B

Page 1: ...L R32 Split Series English Deutsch Fran ais Nederlands Espa ol Italiano E Portugues Pycc T rk e MODELS CTXM15M2V1B FTXM60M2V1B FTXM20M2V1B FTXM71M2V1B FTXM25M2V1B ATXM20M2V1B FTXM35M2V1B ATXM25M2V1B F...

Page 2: ...rtificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 A...

Page 3: ...r B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo...

Page 4: ...ake sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat...

Page 5: ...nd find the site where remote controller signals are properly received by the indoor unit within 7m CAUTION Do not install the air conditioner at any place where there is a danger of flammable gas lea...

Page 6: ...r protection gloves Place both hands under the centre of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 loc...

Page 7: ...g method 1 Remove the service lid screw 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down 30mm or more from ceiling Front panel 50mm or more from walls on both sides...

Page 8: ...side 2 Insert a wall pipe into the hole 3 Insert a wall cover into wall pipe 337 810 A A 294 44 5 170 142 170 447 60 435 990 1040 170 151 5 52 19 5 126 5 48 60 52 300 19 5 117 68 68 44 5 137 137 337 5...

Page 9: ...6 English 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty...

Page 10: ...with both hands to set it on the mounting plate hooks Make sure the wires do not catch on the edge of the indoor unit In the case of bending or curing refrigerant pipes keep the following precautions...

Page 11: ...to the left side 1 Remove the insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighte...

Page 12: ...ITOR Q L OVERLOADPROTECTOR CN E AC HA HE HL HN HR MR _A MR _B S X A CONNECTION CONNECTOR Q M THERMOSWITCH D V D DIODE R RESISTOR DB DIODEBRIDGE R T THERMISTOR DS DIPSWITCH RC RECEIVER E H HEATER S C L...

Page 13: ...is required use appropriate parts that match the hose front end Figure of hose front end 4 When extending the drain hose use a commercially available extension hose with an inner diameter of 16mm Be s...

Page 14: ...er against the hooks 1 Lock the adapter by pressing it down 2 Removing the reverse process of installing Class 50 60 71 Installing Place the wireless adapter into the holder 1 Fix the adapter in the h...

Page 15: ...of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them fully with the torque wrenches 2 1 Caution on piping handling 1 Protect the open end of the pipe against dust and moist...

Page 16: ...standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power...

Page 17: ......

Page 18: ...3P393185 7L 2015 12 Copyright 2015 Daikin...

Reviews: