![background image](http://html1.mh-extra.com/html/daikin/ctxm15a2v1b/ctxm15a2v1b_installers-reference-manual_4699039024.webp)
6
|
Unit installation
Installer reference guide
24
CTXM-A, FTXM-A, ATXM-A
Daikin room air conditioner
4P518023-17P – 2023.06
2
Push the left panel shaft outward and up to disconnect the front panel from
the unit. (Remove the right side front panel shaft in the same manner.)
a
a
Front panel shaft
3
After removing both front panel shaft, pull the front panel toward yourself
and remove it.
6.2.2 To open the service cover
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
b
a
a
Service cover
b
Service cover screw
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
6.2.3 To remove the front grille
CAUTION
Wear adequate personal protective equipment (protective gloves, safety glasses,…)
when installing, maintaining or servicing the system.
1
Remove the front panel, see
"6.2.1 To remove the front panel"
23] and
remove the air filter.
2
"6.2.2 To open the service cover"
24].
3
Remove the lower flap by pushing it to the left side and towards you.
4
If installed, remove the 2 screw covers using a long flat plate such as a ruler
wrapped in a cloth and remove 3 screws fixing the front grille.