6
|
Unit installation
Installer reference guide
26
CTXM-A, FTXM-A, ATXM-A
Daikin room air conditioner
4P518023-17P – 2023.06
4
To re-install the cover, first attach the electrical wiring box to the hooks, close
the electrical wiring box, and re-install the screw.
6.3 Mounting the indoor unit
In this chapter
6.3.1 To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape measure.
Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall using
M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting plate pocket.
(mm)
295
45
50
802
180
102
361
96
46
252
100
45
150
50
341
h
f2
f1
g
b
a
a
a
c
c
a
e d
e
d
a
a
a
a
Recommended mounting plate fixing spots
f1
Measure point for piping hole center " " (to left)
b
Pocket for the pipe port cover
f2
Measure point for piping hole center " " (to right)
c
Tabs for placing a spirit level
g
Gas pipe end