Features / Benefits

EFFICIENCY

CLIWP units are designed to meet the needs of any project for 

telecommunications networks, data centers, laboratories, schools, 

hospitals and industrial use. 

CLIWP units have diverse applications and can be installed 

individually or in any combination to achieve the exact capacity of 

the project. Their high efficiency and easy operation achieves the 

desired temperatures accurately, quickly and with efficient energy 

consumption. 
The CLIWP units can work 1 + 1 (by means of a separately 

purchased sequencer), i.e., one in operation and one in backup. 

The units have different connectivity and remote monitoring options 

using the most common protocols such as ModBus, BACnet and 

TCP/IP.

SELF CONTAINED AND SELF SPACE         

SAVING

The CLIWP unit is completely self-contained. All its components 

are inside the cabinet. It uses no usable space in the room to 

be conditioned, it is installed on an exterior wall with a minimum 

volume, without requiring roof areas or exterior floors.

EASY TO INSTALL

The equipment is assembled, wired, charged with refrigerant, oil 

and is systematically factory tested to ensure that you will have a 

quick and trouble-free installation.

DESIGN

The work carried out by our engineering and development 

department has resulted in equipment with high efficiency in design 

and optimum performance during operation.

The selection of high quality main components, our quality 

processes and the control system during manufacturing, guarantee 

a high performance and safety equipment.

All major components are rigorously tested and validated before 

installation. Each engineered unit has undergone long hours of 

rigorous testing to ensure the efficiency, safety, durability and 

quality of the entire system.

All external paint is baked-on and meets the most stringent quality 

standards (ASTM-B117 1500 hour salt spray test).

The selection of high-end compressors and heat exchangers 

ensures the capacity and high efficiency of the equipment.

All our equipment has a reduced footprint, which facilitates 

installation and maintenance maneuvers, being able to make use 

of stairs, doors and service elevators to move the equipment.

COMMUNICATION

Our equipment can be connected / integrated through different 

communication protocols; such as TCP/IP, ModBUS and BacNet**, 

the most common protocols used in the Air Conditioning industry.

Our equipment keeps track of all programmable variables in 

real time, such as system load monitoring, specific alarms of the 

refrigeration cycle, and the electrical system. As well as detection 

of external factors such as fire or flood (optional sensors).

MAINTENANCE

The simplicity in the design of the equipment allows for maximum 

ease of preventive/corrective maintenance. All major components 

are available to maintenance personnel by simply opening the 

service panels.
If an emergency shutdown occurs, the digital control of the 

equipment will indicate in detail the cause of the alarm, helping to 

facilitate and accelerate the solution of the alarm.

TESTS

NOTE: The warranty policy requires that startup and 

commissioning be performed by qualified 

personnel authorized by the manufacturer. 

The control system ensures the correct operation of the equipment 

by monitoring in real time the condition of the major components 

(high or low refrigerant pressure, compressor conditions and 

electrical power monitoring).
In case of failure, the event will be recorded for later analysis, 

facilitating the location of a possible failure and its solution.

* Depends on the type of control.

** The available communication protocols depend on the type of 

control.

This task is charged with the refrigerant necessary for proper 

operation based on the customer's installation conditions.

The units are tested at full load operation, thermal load and line 

voltage at actual operating conditions.

Summary of Contents for Comfort Flex CLIWP Series

Page 1: ...Control Manual Model 3 RT 5 RT Refrigerant HFC 410A 60 Hz CM Group Wall Mounted Package Part Number CLIWP CM Date 29 May 2023 CLIWP Series Direct Expansion Unit with Scroll Compressor...

Page 2: ...ion and data cover the Comfort Flex product at the time of publication and we reserve the right to make changes in design and construction at any time without notice Manufactured in an ISO 9001 certif...

Page 3: ...ire WARNING If refrigerant leaks from the unit there is a potential choking danger as the refrigerant will displace air in the immediate area Be sure to follow all applicable published industry relate...

Page 4: ...anel NOMENCLATURE CLIWP 036 U F L C T C A P 1 N C D M 1 4 0 FAMILY CAPACITY BTU 036 36 000 Btu H 060 60 000 Btu H DISCHARGE AIR U Upper COMPRESSOR F Fixed COMPRESSOR SIDE L Left R Right VOLTAGE C 208...

Page 5: ...ngent quality standards ASTM B117 1500 hour salt spray test The selection of high end compressors and heat exchangers ensures the capacity and high efficiency of the equipment All our equipment has a...

Page 6: ...3 C Dry load TECHNICAL FEATURES ElectroFin E Coat Coil coating corrosion resistant factory applied ElectroFin E Coat is a flexible water based cationic epoxy polymer using an electrodeposition coating...

Page 7: ...t the system to almost any cloud service either to upload historical data to analysis services deliver alarm messages to alarm processing services or to operate parts of the control system via a cloud...

Page 8: ...next field 3 Finally navigate to Save and Restart and press 4 Confirm the reboot and the device will reboot with the new IP address To set the BACnet device ID through the LCD display 1 On the main L...

Page 9: ...ograms LOYTEC LINX Configurator LOYTEC LINX Configurator The application starts and displays the data point manager screen as shown in Figure 7 2 When the device is online connect to the device by cli...

Page 10: ...2 1 AP Compressor APdx 24 VAC Relay DO 3 1 AC Free Cooling ACf 0 10 VDC AO 1 1 Zone Temp TZ LSTAT MODBUS RTU Total points per Ctrl 3 3 1 3 0 3 To adapt the I O name double click on the name in the Nam...

Page 11: ...nfigured so that the equipment can be turned on and the system points can be modified The following describes the use of the LSTAT thermostat as shown in Fig 9 and the indicators it contains in this c...

Page 12: ...RMS The CLIWP system has 3 alarms The first alarm is triggered by the low pressure switch and the second alarm is triggered by the high pressure switch these alarms are digital signals which are progr...

Page 13: ...ont keypad Access is different depending on the user level support installer and manufacturer parameters Modification of the Assistance parameters The Support parameters as well as the parameters for...

Page 14: ...ard display after 5 minutes NETWORK ADDRESS The network address assigns the controller an address for serial connection to a supervisory system via RS485 and to a pCO controller via pLAN tLAN Modbus I...

Page 15: ...menu Unlike the pressure probes the temperature probes do not have any parameters corresponding to the measuring range that can be changed and therefore only the models listed can be used see the cha...

Page 16: ...nly when heating or cooling In the ON position the fan will run constantly at all times with or without a heating or cooling demand Multifunction slide switch It provides easy access to common setting...

Page 17: ...me delay 5 default The thermostat waits 5 minutes before turning the system back on after the last time it was turned on This internal delay prevents rapid cycling and provides wallpack protection The...

Page 18: ...cm cliwp eng www comfort flex com...