5 Technical data
Service manual
54
ATXP20~3 FTXP20~7 ARXP20~3
RXP20~71L2V1B
Split Comfora R32
ESIE18-01 – 2019.02
5.3.2
Piping diagram: Outdoor unit
Class 20~35
7.0CuT
7.0CuT
9.
5C
uT
9.5
C
uT
4.8CuT
4.8CuT
6.4CuT
6.4CuT
4.
8C
uT
(6.4CuT)
(9.5CuT)
9.5CuT
9.5CuT
9.5
C
uT
9.5CuT
7.
9C
uT
9.
5C
uT
9.5CuT
9.5CuT
a
b
c
d
e
e
f
g
h
M1C
M1F
R1T
R2T
R3T
Y1E
Y1S
a
Field piping (liquid: Ø6.4 mm flare connection)
b
Field piping (gas: Ø9.5 mm flare connection)
c
Stop valve (liquid)
d
Stop valve with service port (gas)
e
Muffler with filter
f
Heat exchanger
g
Accumulator
h
Muffler
M1C
Compressor
M1F
Fan
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (compressor discharge)
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)(ON: cooling)
Heating
Cooling
INFORMATION
The diagrams shown in this manual may be incorrect due
to changes/updates to the unit. Correct diagrams are
supplied with the unit and can also be found in the
technical data book.