Remote Controller (Wireless Type)
OH08-1
56
Control Systems
AIR FLOW DIRECTION ADJUST
UP AND DOWN DIRECTION
z
The movable limit of the flap is changeable. Contact your Daikin dealer for details.
Press the AIR FLOW DIRECTION ADJUST button to select the air direction as shown below.
DISPLAY appears and the air flow direction continuously varies. (Automatic swing
setting)
Press AIR FLOW DIRECTION ADJ UST button to select the air direction of your choice.
DISPLAY vanishes the air flow direction is fixed (Fixed air flow direction setting).
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, micro computer controls the air flow direction so it may be different from the
display.
NOTES
z
If you try cooling or programmed drying, while the flaps are facing downward, air flow direction may
change unexpectedly. There is nothing wrong with the equipment. This serves to prevent dew formed
on parts in the air discharge outlet from dripping.
z
Operation mode includes automatic operation.
(4) Program Timer Operation
Operate in the following order.
z
The timer is operated in the following two ways.
Programming the stop time (
)
.... The system stops
operating after the set time has elapsed.
Programming the start time (
)
.... The system starts
operating after the set time has elapsed.
z
The timer can be programmed a maximum of 72 hours.
z
The start and the stop time can be simultaneously programmed.
SWING
Operation mode
Cooling
Heating
Operation conditions
z
When operating continuously at
horizontal air flow direction
z
When room temperature is higher
than the set temperature
z
At defrost operation
(The flaps blow horizontally to
avoid blowing cold air directly on
the occupants of the room.)
Up and down adjustment