background image

OH08-1

R e m o te  C o n tr o lle r  (W ir e le s s  T y p e )

Control Systems

4 7

2

2.3

B R C 7 F 6 3 4 F  / B R C 7 F 6 3 5 F  (F o r  F X F Q -P )

2.3 .1

F e a tu re s

B R C 7 F 6 3 4 F  (fo r  He a t P u m p )
B R C 7 F 6 3 5 F  (fo r  C o o lin g  On ly )

„

T h e sa me op era tion mod es a nd  setting s a s w ith  w ired  remote c ontrollers a re p ossib le.

„

A  lig h t rec eiv er u nit for a  Ceiling  M ou nted  Ca ssette (R ou nd  F low ) typ e is mou nted  into th e ind oor u nit.

„

T h is u nit su p p orts th e th ree-sp eed  a irflow  ra te c ontrol (H H  / H  / L ).

2.3 .2

F u n c tio n

Sig na l rec eiv er u nit 

(Insta lled  typ e)

Sig na l rec eiv er u nit c a n 
b e insta lled  on th e p a nel

M od el

B R C7 F 6 3 4 F /6 3 5 F

O N /O F F

P ossib le

T emp . setting

P ossib le

A ir flow  ra te setting

P ossib le

A ir flow  d irec tion setting

P ossib le

T imer setting

P ossib le

M od e setting

P ossib le

F ilter sig n reset

P ossib le

Insp ec tion/T est op era tion

P ossib le

2

.2

  B

R

C

7

E

6

1

W

 / 

B

R

C

7

E

6

5

 / 

2

.3

  B

R

C

7

F

6

3

4

F

 / 

B

R

C

7

F

6

3

5

F

Summary of Contents for BRC7E61W

Page 1: ...low typ e is mou nted into th e ind oor u nit T h is u nit su p p orts th e th ree sp eed a irflow ra te c ontrol H H H L 2 3 2 F u n c tio n Sig na l rec eiv er u nit Insta lled typ e Sig na l rec e...

Page 2: ...D RAIN PIPING SID E RE CE IV E R INSTALLATION PROCE D U RE RE FRIG E RANT PIPING SID E RE CE IV E R D E TAIL W IRE LE SS RE MOTE CONTROLLE R K IT FOR E ACH D E CORATION PANE L RE MOTE CONTROLLE R D I...

Page 3: ...f th e Operating S ection 1 1 3 2 1 1 1 2 8 10 13 11 12 15 14 16 17 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr h...

Page 4: ...AMMING TIMER BU TTON Use this button for programming START and or STOP time Operates with the front cover of the remote controller opened 12 TIMER MODE START STOP BU TTON Refer to page 57 13 TIMER RES...

Page 5: ...mote controller Direct the transmitting part of the remote controller to the receiv ing part of the air conditioner If something blocks the transmitting and receiving path of the indoor unit and the r...

Page 6: ...r normal use batteries last about a year However change them whenever the indoor unit doesn t respond or responds slowly to commands or if the display becomes dark CAUTIONS z Replace all batteries at...

Page 7: ...te in the following order z AUTOMATIC OPERATION can be selected only by Heat pump split system or Heat recovery VRV system z For cooling only type COOLING and FAN and DRY operation are able to select...

Page 8: ...mp lights up or goes off and the system starts or stops OPERATION z The fan may keep on running for about 1 minute after the heating operation stops for removing the heat in the indoor unit z The air...

Page 9: ...purchase 3 Adjustment For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPERATURE SETTING Press TEMPERATURE SETTING button and program the setting temper...

Page 10: ...facing downward air flow direction may change unexpectedly There is nothing wrong with the equipment This serves to prevent dew formed on parts in the air discharge outlet from dripping z Operation m...

Page 11: ...ocedure ends The display or changes from flashing light to a constant light TIMER CANCEL Press the TIMER OFF button to cancel programming The display vanishes For example When the timer is programmed...

Page 12: ...peration mode between FAN DRY and COOL When the indoor unit with master remote controller is set to HEAT you can switch over operation mode between FAN and HEAT When the indoor unit with master remote...

Page 13: ...rates with the previously set air flow direction STOP Press the EMERGENCY OPERATION switch again 7 Precautions for Group Control System or Two Remote Controller Control System This system provides two...

Page 14: ...tioner the communication between the units is cut off and the unit stops When the noise is gone the unit automatically restarts III NO CHANGEOVER IS AVAILABLE BETWEEN HEATING AND COOLING MODES z The i...

Page 15: ...until the indoor unit beeps and perform the following operation according to the number of beeps Number of beeps 3 short beeps Perform all steps from 3 to 6 1 short beep Perform 3 and 6 steps 1 long...

Page 16: ...of the same number Signal transmitted from a remote controller of a different number cannot be accepted If the number is not mentioned it is considered as 1 2 The system operates but it does not suff...

Page 17: ...the unit does not work at all Remedial action Check the malfunction code A1 UF on the remote control and contact the place of purchase See page 60 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIM...

Page 18: ...ther a source of light nor fluorescent lamp near the receiver Also ensure that the receiver is not exposed of direct sun light z Ensure that the operaiton display lamp and other indicators are easy to...

Page 19: ...roller by sliding it in the direction of the arrow 2 Insert the attached dry cell batteries Properly insert set the batteries by matching the and polarity marks as indicated Then close the cover as be...

Page 20: ...and make the multiple setting as shown below 3 Stick the Unit No label on the air outlet of the decoration panel and the back of the wireless remote controller PRECAUTIONS Set the Unit No of the rece...

Page 21: ...harnesses from the transmission using provided clamps Installation of the Decoration Panel Install the decoration panel as described in the Installation Manual supplied with the decoration panel NOTE...

Page 22: ...re 1 When in the normal mode press the button for a minimum of four seconds and the FIELD SET MODE is entered 2 Select the desired MODE NO with the button 3 Push the button and select the FIRST CODE N...

Page 23: ...tting for spacing time of display time to clean air filter Setting for when filter contamination is heavy and spacing time of display time to clean air filter is to be halved Ultra long life type ligh...

Reviews: