background image

English

3

Englis

h

Installation Tips

1.

Removing and installing front panel.

• Removal method

1) Place your fingers in the indentations on the main unit (one each on the 

left and right sides), and open the panel until it stops.Continue to open 
the front panel further while sliding the panel to the right and pulling it 
toward you in order to disengage the rotating shaft on the left side. To 
disengage the rotating shaft on the right side, slide the panel to the left 
while pulling it toward you.

• Installation method

Align the tabs of the front panel with the grooves, and push all the way in. 
Then close slowly. Push the center of the lower surface of the panel firmly 
to engage the tabs.

2.

Removing and installing front grille.

• Removal method

1) Remove the front panel to remove the air filter.
2) Remove the screws (2) from the front grille.
3) In front of the 

 mark of the front grille, there are 3 upper hooks.

Lightly pull the front grille toward you with one hand, and push down on 
the hooks with the fingers of your other hand.

When there is no work space because the unit is close to ceiling

 CAUTION

Be sure to wear protection gloves.

Place both hands under the center of the front grille, and while pushing up, pull it toward you.

• Installation method

1) Install the front grille and firmly engage the upper hooks (3 locations).
2) Install 2 screws of the front grille.
3) Install the air filter and then mount the front panel.

3.

How to set the different addresses.

When two indoor units are installed in one room, the two wireless remote control-
lers can be set for different addresses.
1) In the same way as when connecting to an HA system, remove the metal 

plate electrical wiring cover.

2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.

Indentations on 
the main unit

Push the rotating 
shaft of the front 
panel into the groove.

Rotating shaft

Lightly pull the front 
grille toward you with 
one hand, and push 
down on the hooks with 
the fingers of your other 
hand. (3 locations)

Push 
down.

Upper hook

Upper hook

Upper hook

mark area

(3 locations)

1) Push up.

2) Pull toward you.

ADDRESS

J4

EXIST

CUT

1
2

J4

3PEN341265-5Q.book  Page 3  Friday, March 17, 2017  10:56 AM

Summary of Contents for ATXB25C

Page 1: ...5C2V1B FTXB35C2V1B ATXB25C2V1B ATXB35C2V1B 3PEN341265 5Q book Page 1 Friday March 17 2017 10 56 AM Questo manuale d istruzione fornito da trovaprezzi it Scopri tutte le offerte per Daikin ATXB25C o ce...

Page 2: ...orado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer po...

Page 3: ...ric shock or fire Use the specified types of wires for electrical connections between the indoor and outdoor units Firmly clamp the interconnecting wires so their terminals receive no external stresse...

Page 4: ...e room if any and find the site where remote control signals are properly received by the indoor unit within 7 metres CAUTION Do not install the air conditioner in a place where there is danger of exp...

Page 5: ...s of your other hand When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing...

Page 6: ...weight of the indoor unit Mounting plate Screws Field supply M4 25L M4 16L 75mm or more from ceiling Front panel 50mm or more from walls on both sides Air filters Service lid Opening service lid Servi...

Page 7: ...nded mounting plate retention spots and Dimensions Use tape measure as shown Position the end of a tape measure at Keep here the piece cut out from the unit for piping Liquid pipe end Gas pipe end The...

Page 8: ...insulation tape 3 Pass the drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide 4...

Page 9: ...right to remove the drain hose 2 Reattach the insulation fixing screw on the right as it was Forgetting to attach this may cause water leakages 3 Remove the drain plug on the left side and attach it...

Page 10: ...s stranded wires extension cords or starburst connections as they may cause overheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the po...

Page 11: ...HL HN HR MR _A MR _B S U V W X A CONNECTION CONNECTOR Q L OVERLOAD PROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHAR...

Page 12: ...l oil on flared part 2 Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts...

Page 13: ...urface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as...

Page 14: ...he circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Trial operation from rem...

Page 15: ...3PEN341265 5Q book Page 1 Friday March 17 2017 10 56 AM...

Page 16: ...3P341265 5Q 2017 02 Copyright 2014 Daikin 3PEN341265 5Q book Page 2 Friday March 17 2017 10 56 AM...

Reviews: