Indoor Unit Installation

Wiring diagram

CAUTION
Note that operation will restart automatically if the main power supply is turned off and then back on again.
HIGH VOLTAGE – be sure to discharge the capacitor completely before repair work.
Risk of failure or water leakage!
Do not wash the inside of the air conditioner by yourself.

Unified Wiring Diagram Legend

For applied parts and numbering refer to the wiring diagram sticker supplied on the unit. Part numbering is realized by Arabic numbers in ascending order for each part and

 is represented in the overview below by symbol “*” in the part code.

:

CIRCUIT BREAKER

:

PROTECTIVE EARTH

:

CONNECTION

:

PROTECTIVE EARTH (SCREW)

,

:

CONNECTOR

:

RECTIFIER

:

EARTH

:

RELAY CONNECTOR

:

FIELD WIRING

:

SHORT CIRCUIT CONNECTOR

:

FUSE

:

TERMINAL

䣋䣐䣆䣑䣑䣔

:

INDOOR UNIT

:

TERMINAL STRIP

䣑䣗䣖䣆䣑䣑䣔

:

OUTDOOR UNIT

:

WIRE CLAMP

BLK

:

BLACK

GRN

:

GREEN

PNK

:

PINK

WHT

:

WHITE

BLU

:

BLUE

GRY

:

GREY

PRP, PPL

:

PURPLE

YLW

:

YELLOW

BRN

:

BROWN

ORG

:

ORANGE

RED

:

RED

A*P

:

PRINTED CIRCUIT BOARD

PS

:

SWITCHING POWER SUPPLY

BS*

:

PUSH BUTTON ON / OFF, OPERATION SWITCH

PTC*

:

THERMISTOR PTC

BZ, H*O

:

BUZZER

Q*

:

INSULATED GATE BIPOLAR TRANSISTOR (IGBT)

C*

:

CAPACITOR

Q*DI

:

EARTH LEAK CIRCUIT BREAKER

AC*, CN*, E*, HA*, HE, HL*, HN*, 
HR*, MR*_A, MR*_B, S*, U, V, 
W, X*A

:

CONNECTION, CONNECTOR

Q*L

:

OVERLOAD PROTECTOR

D*, V*D

:

DIODE

Q*M

:

THERMO SWITCH

DB*

:

DIODE BRIDGE

R*

:

RESISTOR

DS*

:

DIP SWITCH

R*T

:

THERMISTOR

E*H

:

HEATER

RC

:

RECEIVER

F*U, FU* 

(FOR CHARACTERISTICS 

REFER TO PCB INSIDE YOUR UNIT)

:

FUSE S*C

:

LIMIT 

SWITCH

FG*

:

CONNECTOR (FRAME GROUND)

S*L

:

FLOAT SWITCH

H*

:

HARNESS

S*NPH

:

PRESSURE SENSOR (HIGH)

H*P, LED*, V*L

:

PILOT LAMP, LIGHT EMITTING DIODE

S*NPL

:

PRESSURE SENSOR (LOW)

HAP

:

LIGHT EMITTING DIODE (SERVICE MONITOR GREEN)

S*PH, HPS*

:

PRESSURE SWITCH (HIGH)

HIGH VOLTAGE

:

HIGH VOLTAGE

S*PL

:

PRESSURE SWITCH (LOW)

IES

:

INTELLIGENT EYE SENSOR

S*T

:

THERMOSTAT

IPM*

:

INTELLIGENT POWER MODULE

S*W, SW*

:

OPERATION SWITCH

K*R, KCR, KFR, KHuR

:

MAGNETIC RELAY

SA*

:

SURGE ARRESTOR

L

:

LIVE

SR*, WLU

:

SIGNAL RECEIVER

L*

:

COIL

SS*

:

SELECTOR SWITCH

L*R

:

REACTOR

SHEET METAL

:

TERMINAL STRIP FIXED PLATE

M*

:

STEPPER MOTOR

T*R

:

TRANSFORMER

M*C

:

COMPRESSOR MOTOR

TC, TRC

:

TRANSMITTER

M*F

:

FAN MOTOR

V*, R*V

:

VARISTOR

M*P

:

DRAIN PUMP MOTOR

V*R

:

DIODE BRIDGE

M*S

:

SWING MOTOR

WRC

:

WIRELESS REMOTE CONTROLLER

MR*, MRCW*, MRM*, MRN* 

:

MAGNETIC RELAY

X*

:

TERMINAL

N

:

:

NEUTRAL

X*M

:

TERMINAL STRIP (BLOCK)

n = *

NUMBER OF PASSES THROUGH FERRITE CORE

Y*E

:

ELECTRONIC EXPANSION VALVE COIL

PAM

:

PULSE-AMPLITUDE MODULATION

Y*R, Y*S

:

REVERSING SOLENOID VALVE COIL

PCB*

:

PRINTED CIRCUIT BOARD

Z*C

:

FERRITE CORE

PM*

:

POWER MODULE

ZF, Z*F

:

NOISE FILTER

CIRCUIT BREAKER

3PEN341265-5Q.book  Page 9  Friday, March 17, 2017  10:56 AM

Summary of Contents for ATXB25C

Page 1: ...5C2V1B FTXB35C2V1B ATXB25C2V1B ATXB35C2V1B 3PEN341265 5Q book Page 1 Friday March 17 2017 10 56 AM Questo manuale d istruzione fornito da trovaprezzi it Scopri tutte le offerte per Daikin ATXB25C o ce...

Page 2: ...orado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer po...

Page 3: ...ric shock or fire Use the specified types of wires for electrical connections between the indoor and outdoor units Firmly clamp the interconnecting wires so their terminals receive no external stresse...

Page 4: ...e room if any and find the site where remote control signals are properly received by the indoor unit within 7 metres CAUTION Do not install the air conditioner in a place where there is danger of exp...

Page 5: ...s of your other hand When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing...

Page 6: ...weight of the indoor unit Mounting plate Screws Field supply M4 25L M4 16L 75mm or more from ceiling Front panel 50mm or more from walls on both sides Air filters Service lid Opening service lid Servi...

Page 7: ...nded mounting plate retention spots and Dimensions Use tape measure as shown Position the end of a tape measure at Keep here the piece cut out from the unit for piping Liquid pipe end Gas pipe end The...

Page 8: ...insulation tape 3 Pass the drain hose and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide 4...

Page 9: ...right to remove the drain hose 2 Reattach the insulation fixing screw on the right as it was Forgetting to attach this may cause water leakages 3 Remove the drain plug on the left side and attach it...

Page 10: ...s stranded wires extension cords or starburst connections as they may cause overheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the po...

Page 11: ...HL HN HR MR _A MR _B S U V W X A CONNECTION CONNECTOR Q L OVERLOAD PROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHAR...

Page 12: ...l oil on flared part 2 Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts...

Page 13: ...urface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as...

Page 14: ...he circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Trial operation from rem...

Page 15: ...3PEN341265 5Q book Page 1 Friday March 17 2017 10 56 AM...

Page 16: ...3P341265 5Q 2017 02 Copyright 2014 Daikin 3PEN341265 5Q book Page 2 Friday March 17 2017 10 56 AM...

Reviews: