Printed Circuit Board Connector Wiring Diagram
SiEN04-306D
36
Printed Circuit Board Connector Wiring Diagram
1. Printed Circuit Board Connector Wiring Diagram
1.1
Indoor Unit
Connectors
Note:
Other designations
Note:
Following parts are not on FT(Y)S 50 / 60B series:
Intelligent Eye sensor PCB
S8
S35
LED3
1) S1
Connector for fan motor
2) S6
Connector for swing motor (horizontal blades)
3) S8
Connector for swing motor (vertical blades)
4) S21
Connector for centralized control (HA)
5) S26, S37
Connector for buzzer PCB
6) S27, S29, S36 Connector for control PCB
7) S28
Connector for signal receiver PCB
8) S32
Connector for heat exchanger thermistor
9) S35
Connector for Intelligent Eye sensor PCB
10) S38
Connector for display PCB
1) V1
Varistor
2) JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function
* Refer to page 193 for detail.
3) SW1
Forced operation ON / OFF switch
4) LED1
LED for operation (green)
5) LED2
LED for timer (yellow)
6) LED3
LED for Home Leave operation (red)
7) LED A
Service monitor LED (green)
8) FU1
Fuse (3.15A)
9) RTH1
Room temperature thermistor
Summary of Contents for ARXS50C2VMB
Page 109: ...Instruction SiEN04 306D 100 System Configuration ...
Page 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure ...
Page 203: ...Others SiEN04 306D 194 Others ...
Page 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS ...
Page 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS ...