11 Technical data
Installation manual
47
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685229-1A – 2022.05
English
Translation
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Remote user interface
Remote user interface
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Safety thermostat contact:
16 V DC detection (voltage
supplied by PCB)
Smartgrid contacts
Smart Grid contacts
Smartgrid PV power pulse meter Smart Grid photovoltaic power
pulse meter
SWB
Switch box
(7) External On/OFF thermostats
and heat pump convector
(7) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Additional leaving water
temperature zone
Main LWT zone
Main leaving water temperature
zone
Only for ext. sensor (floor or
ambient)
Only for external sensor (floor or
ambient)
Only for heat pump convector
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Only for wireless On/OFF
thermostat
Only for ***
Only for ***
Hydro module — Internal backup heater
Translation of text on wiring diagram:
English
Translation
(1) Connection diagram
(1) Connection diagram
For internal BUH option
For models with integrated
backup heater
Hydro
Hydro module
Outdoor
Outdoor
SWB
Hydro switch box
(2) Notes
(2) Notes
X1M
Terminal (main)
X2M
Terminal (field wiring for AC)
X4M
Terminal (booster heater power
supply)
X5M
Terminal (field wiring for DC)
X9M
Terminal (integrated backup
heater power supply)
X10M
Terminal (Smart Grid)
Earth wiring
Field supply
1
Several wiring possibilities
Option
Wiring depending on model
Switch box
PCB
(3) BUH switch box
(3) Backup heater switch box
Rear
Rear
(4) Legend
(4) Legend
*: Optional; #: Field supply
A1P
Main PCB
A4P
* Digital I/O PCB
English
Translation
A8P
* Demand PCB
F1B
# Overcurrent fuse backup heater
K1A, K2A
* High voltage Smart Grid relay
K1M
Safety contactor backup heater
K3M
* Contactor booster heater
Q1DI
# Earth leakage circuit breaker
TR1
Power supply transformer
X4M
* Terminal strip (booster heater
power supply)
X6M
# Terminal strip (power supply at
client side)
X9M
Terminal strip (integrated backup
heater power supply)
X10M
* Terminal (high voltage Smart
Grid)
X*A
Connector
X*M
Terminal strip
Summary of Contents for ALTHERMA
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ...4P685229 1A 2022 05 Copyright 2022 Daikin Verantwortung für Energie und Umwelt ...