11 Technical data
Installation manual
43
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685229-1A – 2022.05
11
Technical data
A
subset
of the latest technical data is available on the regional Daikin website (publicly accessible). The
full set
of latest technical data is
available on the Daikin Business Portal (authentication required).
11.1
Piping diagram: Outdoor unit
EBLA04~08E23V3, EDLA04~08E23V3
A
B
a2
j
i
h
g
f
b
B
1P
R
m
l
u
n
o
p
q
S1
PH
t
s
r
t
k
e
a1
c
d
b
B1
PW
3D139436 A
R2T
R1T
R2T
R3T
R1T
R4T
R3T
A
Hydro module
B1PW
Space heating water pressure sensor
B
Compressor module
B1PR
Refrigerant pressure sensor
S1PH
High pressure switch
A1
Water IN (screw connection, male, 1")
A2
Water OUT (screw connection, male, 1")
Thermistors (hydro module):
b
Drain valve (water circuit)
R1T
Outlet water heat exchanger
c
Expansion vessel
R3T
Refrigerant liquid side
d
Flow sensor
R4T
Inlet water
e
Plate heat exchanger
f
Backup heater
Thermistors (compressor module):
g
Automatic air purge valve
R1T
Outdoor air
h
Safety valve
R2T
Air heat exchanger
i
Pump
R3T
Compressor discharge
j
Connection for optional flow switch
k
Liquid stop valve
Refrigerant flow:
l
Filter
Heating
m
Electronic expansion valve
Cooling
n
Muffler with filter
o
Distributor
Connections:
p
Heat exchanger
Screw connection
q
4‑way valve
Flare connection
r
Accumulator
Quick coupling
s
Compressor
Brazed connection
t
Muffler
u
Gas stop valve with service port