15
|
Technical data
Installer reference guide
191
C08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
15 Technical data
A
subset
of the latest technical data is available on the regional Daikin website
(publicly accessible). The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
15.1 Piping diagram: Indoor unit
A
B
1
2
3
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
3D082238-1B
A
Water side
B
Refrigerant side
1
Space heating water IN
2
Space heating water OUT
3
Shut‑off valve with drain/fill valve
4
Expansion vessel
5
Filter
6
Pump
7
Plate heat exchanger
8
Air purge
9
Flow sensor
10
3‑way valve
11
Safety valve
12
Gas boiler
13
Domestic hot water: hot water OUT
14
Gas pipe
15
Domestic hot water: hot water IN
16
R1T – Plate heat exchanger outlet water thermistor
17
R2T – Outlet water thermistor
18
R3T – Heat exchanger liquid pipe thermistor
19
R4T – Inlet water thermistor
20
Screw connection
Screw connection