background image

3 Operation

Operation manual

4

08S18+23DA + 08S18+23DJ

Daikin Altherma 3 R F

4P584430-1 – 2019.06

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

3.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

18 Feb 2018

22:19

55

18

21
45

f

i

j

h

g

e

d

a

b

c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

21

21

The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.

Outdoor
unit

a2 a3

a1

a1

: Outdoor unit

a2

: Quiet mode active

a3

Measured ambient temperature

Item

Description

Indoor unit /
domestic
hot water
tank

b1

b2

b1

Indoor unit:

: Floor-standing indoor unit with integrated

tank

b2

Water pressure

Space
operation
mode

c

: Heating

Disinfection
 / Powerful

d

: Disinfection mode active

: Powerful operation active

Date / time

e

Current date and time

Holiday

f

: Holiday mode active

Main zone

g3
g1

g4
g2

g1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

g2

Leaving water temperature setpoint

g3

Room thermostat type:

:  Daikin  user  interface  used  as  room

thermostat

: External control

▪ Hidden: Leaving water temperature control

g4

Measured room temperature

Additional
zone

h3
h1 h2

h1

Heat emitter type:

Underfloor heating

Fancoil unit

Radiator

h2

Leaving water temperature setpoint

h3

Room thermostat type:

: External control

▪ Hidden: Leaving water temperature control

Domestic
hot water

i1 i2

i1

: Domestic hot water

i2

Measured tank temperature

Malfunction

j

 or 

: A malfunction occurred

See 

"6.1 To display the help text in case of a

malfunction" on page 12

 for more information.

3.2.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Summary of Contents for Altherma EHVZ08S18DA6V

Page 1: ...Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G EHVZ04S18DJ6V G EHVZ08S18DJ6V G EHVZ08S23DJ6V G EHVZ08S18...

Page 2: ...uest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for...

Page 3: ...a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user perm...

Page 4: ...Indoor unit Floor standing indoor unit with integrated tank b2 Water pressure Space operation mode c Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Curr...

Page 5: ...es access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heating functionality and...

Page 6: ...settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2...

Page 7: ...up the water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot...

Page 8: ...ft dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20...

Page 9: ...ct Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2...

Page 10: ...er settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B Us...

Page 11: ...ple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up th...

Page 12: ...To change the desired room temperature on page 6 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the room t...

Page 13: ...function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before you purge air fro...

Page 14: ......

Page 15: ......

Page 16: ...4P584430 1 2019 06 Copyright 2017 Daikin 4P584430 1 0000000M...

Reviews: