background image

3 Operation

Operation manual

9

08S18+23DA + 08S18+23DJ
Daikin Altherma 3 R F
4P584430-1 – 2019.06

5

Repeat this action for all other weekdays.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

To program the schedule for 

Saturday

 and copy it to 

Sunday

:

1

Select 

Saturday

.

2

Select 

Edit

.

3

Use the left dial to select an entry and edit the entry
with the right dial.

0

8:00

23:00

--:--

21°C
18°C

--

12

24

Sat

4

Confirm the changes.

5

Select 

Saturday

.

6

Select 

Copy

.

7

Select 

Sunday

.

8

Select 

Paste

.

Result:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

C

To rename the schedule:

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select 

Rename

.

Delete

Rename

Select

3

(optional) To delete the current schedule name,
browse through the character list until 

 is

displayed, then press to remove the previous
character. Repeat for each character of the schedule
name.

4

To name the current schedule, browse through the
character list and confirm the selected character.
The schedule name can contain up to 15 characters.

5

Confirm the new name.

INFORMATION

Not all schedules can be renamed.

Summary of Contents for Altherma EHVZ08S18DA6V

Page 1: ...Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G EHVZ04S18DJ6V G EHVZ08S18DJ6V G EHVZ08S23DJ6V G EHVZ08S18...

Page 2: ...uest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for...

Page 3: ...a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user perm...

Page 4: ...Indoor unit Floor standing indoor unit with integrated tank b2 Water pressure Space operation mode c Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Curr...

Page 5: ...es access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heating functionality and...

Page 6: ...settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2...

Page 7: ...up the water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot...

Page 8: ...ft dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20...

Page 9: ...ct Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2...

Page 10: ...er settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B Us...

Page 11: ...ple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up th...

Page 12: ...To change the desired room temperature on page 6 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the room t...

Page 13: ...function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before you purge air fro...

Page 14: ......

Page 15: ......

Page 16: ...4P584430 1 2019 06 Copyright 2017 Daikin 4P584430 1 0000000M...

Reviews: