Daikin Altherma EHVZ08S18DA6V Operation Manual Download Page 13

7 Disposal

Operation manual

13

08S18+23DA + 08S18+23DJ
Daikin Altherma 3 R F
4P584430-1 – 2019.06

When  the  heat  pump  fails, 

  or 

  will  appear  on  the  user

interface.

Possible cause

Corrective action

Heat pump is damaged.

See 

"6.1 To display the help text

in case of a malfunction" on
page 12

.

INFORMATION

When  the  backup  heater  takes  over  the  heat  load,
electricity consumption will be considerably higher.

6.5

Symptom: The system is making
gurgling noises after
commissioning

Possible cause

Corrective action

There is air in the system.

Purge air from the system.

(a)

Various malfunctions.

Check if 

 or 

 is displayed

on the home screen of the user
interface. See 

"6.1 To display the

help text in case of a
malfunction" on page 12

 for more

information about the
malfunction.

(a)

We recommend to purge air with the air purge function of
the unit (to be performed by the installer). If you purge air
from the heat emitters or collectors, mind the following:

WARNING

Air  purging  heat  emitters  or  collectors.

  Before  you

purge  air  from  heat  emitters  or  collectors,  check  if 

  or

 is displayed on the home screen of the user interface.

▪ If not, you can purge air immediately.

▪ If  yes,  make  sure  that  the  room  where  you  want  to

purge air is sufficiently ventilated. 

Reason:

 Refrigerant

might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.

7

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

8

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Summary of Contents for Altherma EHVZ08S18DA6V

Page 1: ...Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G EHVZ04S18DJ6V G EHVZ08S18DJ6V G EHVZ08S23DJ6V G EHVZ08S18...

Page 2: ...uest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for...

Page 3: ...a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user perm...

Page 4: ...Indoor unit Floor standing indoor unit with integrated tank b2 Water pressure Space operation mode c Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Curr...

Page 5: ...es access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heating functionality and...

Page 6: ...settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2...

Page 7: ...up the water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot...

Page 8: ...ft dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20...

Page 9: ...ct Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2...

Page 10: ...er settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B Us...

Page 11: ...ple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up th...

Page 12: ...To change the desired room temperature on page 6 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the room t...

Page 13: ...function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before you purge air fro...

Page 14: ......

Page 15: ......

Page 16: ...4P584430 1 2019 06 Copyright 2017 Daikin 4P584430 1 0000000M...

Reviews: