background image

3 Operation

Operation manual

3

08S18+23DA + 08S18+23DJ
Daikin Altherma 3 R F
4P584430-1 – 2019.06

2.1

Components in a typical system
layout

d

a

b c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface used as room thermostat

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

3

Operation

3.1

User interface: Overview

The user interface has the following components:

a

b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"6.1 To display the help text

in case of a malfunction" on
page 12

 for more information.

LCD screen

The LCD screen has a sleeping function. After a certain time of non-
interaction with the user interface, the screen darkens. Pressing any
button  or  rotating  any  dial  awakens  the  display.  The  time  of  non-
interaction differs depending on the user permission level:

User

 or 

Advanced user

: 15 min

Installer

: 1 h

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

: Turn, then press the left dial. Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

3.2

Possible screens: Overview

The most common screens are as follows:

Summary of Contents for Altherma EHVZ08S18DA6V

Page 1: ...Altherma 3 R F English Operation manual Daikin Altherma 3 R F EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W G EHVZ04S18DJ6V G EHVZ08S18DJ6V G EHVZ08S23DJ6V G EHVZ08S18...

Page 2: ...uest the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for...

Page 3: ...a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user perm...

Page 4: ...Indoor unit Floor standing indoor unit with integrated tank b2 Water pressure Space operation mode c Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Curr...

Page 5: ...es access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profile C Operation Turn heating functionality and...

Page 6: ...settings in case of problems You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2...

Page 7: ...up the water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating and capacity shortage comfort problems is significant In case of frequent domestic hot...

Page 8: ...ft dial to select an entry and edit the entry with the right dial You can program up to 6 actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20...

Page 9: ...ct Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2...

Page 10: ...er settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B Us...

Page 11: ...ple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up th...

Page 12: ...To change the desired room temperature on page 6 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the room t...

Page 13: ...function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before you purge air fro...

Page 14: ......

Page 15: ......

Page 16: ...4P584430 1 2019 06 Copyright 2017 Daikin 4P584430 1 0000000M...

Reviews: