3/9
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.2.1.5
[5-0D]
R/W
0: 1P,(1/2)
1: 1P,(1/1+2)
2: 3P,(1/2)
3: 3P,(1/1+2) (*3)
4: 3PN,(1/2)
5: 3PN,(1/1+2) (*4)
A.2.1.6
[D-01]
R/W
0: No
1: Active open
2: Active closed
A.2.1.7
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
0: No
1: Yes
A.2.1.B
R/W
0: At unit
1: In room
└─
Options
A.2.2.1
[E-05]
R/W
0: No (*1)
1: Yes (*2)
A.2.2.3
[E-07]
R/W
0~6
0: Type 1 (*1)
1: Type 2 (*2)
A.2.2.4
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.5
[C-06]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.6.1
[C-02]
Digital I/O PCB
Ext. backup heat src
R/W
0: No
1: Bivalent
2: -
3: -
A.2.2.6.2
[D-07]
Digital I/O PCB
Solar kit
R/W
0: No
1: Yes
A.2.2.6.3
[C-09]
Digital I/O PCB
Alarm output
R/W
0: Normally open
1: Normally closed
A.2.2.6.4
[F-04]
Digital I/O PCB
Bottom plate heater
R/W
0: No
1: Yes
A.2.2.7
[D-04]
R/W
0: No
1: Pwr consmp ctrl
A.2.2.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.9
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.A
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.D
[E-0B]
Bi-zone kit
Is a bi-zone kit installed?
R/O
0: No
(#)
└─
Capacities
A.2.3.1
[6-02]
R/W
0~10kW, step: 0,2kW
0kW
A.2.3.2
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.2.3.3
[6-04]
R/W
0~10kW, step: 0,2kW
0kW (*3)
6kW (*4)
A.2.3.6
[6-07]
R/W
0~200W, step: 10W
0W
Space operation
└─
LWT settings
└──────────────────
Main
A.3.1.1.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~depending on outdoor unit, step: 1°C
55°C
A.3.1.1.2.3
[9-03]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.1.2.4
[9-02]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
A.3.1.1.5
[8-05]
R/W
0: No
1: Yes
A.3.1.1.6.1
[F-0B]
Shut-off valve
Thermo On/OFF
R/W
0: No
1: Yes
A.3.1.1.6.2
[F-0C]
Shut-off valve
Cooling
R/W
0: No
1: Yes
A.3.1.1.7
[9-0B]
R/W
0: Quick
1: Slow
└──────────────────
Additional
A.3.1.2.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1
[9-05]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
LWT setpoint mode
Modulated LWT
Emitter type
LWT setpoint mode
DHW pump
External sensor
Booster heater
BUH: step 1
BUH: step 2
Bottom plate heater
DHW tank type
Contact type main
Contact type add.
Demand PCB
External kWh meter 1
External kWh meter 2
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
DHW operation
BUH type
Preferential kWh rate
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*
(#) Setting is not applicable for this unit.