3 Operation

Operation manual

5

EBLQ+EDLQ011~016CA(3)V3+W1
Daikin Altherma low temperature monobloc
4P537989-1 – 2018.05

3.3.3

Room thermostat control - Using the
leaving water temperature home pages

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.

Example: 

Underfloor heating is designed for lower leaving

water  temperature  than  radiators  and  heat  pump
convectors  and/or  fan  coil  units.  You  only  have  to  adjust
leaving water temperature settings in case of problems.

For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  ( ),the  DHW  tank  continuously  heats  up  to  the
temperature  shown  on  the  DHW  tank  temperature  home  page
(example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

DHW tank temperature

t

Time

INFORMATION

There  is  a  risk  of  space  heating  (cooling)  capacity
shortage/comfort problem (in case of frequent domestic hot
water  operation,  frequent  and  long  space  heating/cooling
interruption  will  happen)  when  selecting  [6‑0D]=0  ([A.4.1]
Domestic  hot  water  Type=Reheat  only)  in  case  of  a
domestic hot water tank without an internal booster heater.

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating/cooling  function
is regularly interrupted.

3.4.2

Scheduled mode

In  scheduled  mode  ( ),  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because the space heating demand is
lower.

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

3.4.3

Sch reheat mode

In sch reheat mode (   ), the domestic hot water control is
the  same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

DHW tank temperature

t

Time

3.4.4

Using the DHW tank temperature home
page

Typical DHW tank temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  The  examples  in  the  illustrations
below are in DHW tank mode = Scheduled.

User profile = Basic

User profile = Detailed

15:20

60°C

Storage comfort

Tank

Mon

15:20

60°C

00:00

Mon

Tue

Tank

Storage comfort

To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)

1

Go  to  [7.4.3.3]: 

  >  User  settings  >  Preset  values  >  Tank

temperature > Reheat.

Result: 

You can read out the desired reheat temperature.

2

Press 

 or 

 to adjust.

To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)

1

Go to the DHW tank temperature home page (Tank).

Result: 

60°C

 is displayed.

2

Press 

 or 

 to overrule. 

Note: 

If the desired temperature is

weather dependent, you cannot change it on the home page.

3.4.5

Using the DHW tank booster mode

To activate the DHW tank booster mode (user profile = Basic)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (user profile = Detailed)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

Summary of Contents for Altherma EBLQ011-016C3V3

Page 1: ...nobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CA 3 V3 EBLQ014CA 3 V3 EBLQ016CA 3 V3 EBLQ011CA 3 W1 EBLQ014CA 3 W1 EBLQ016CA 3 W1 EDLQ011CA 3 V3 EDLQ014CA 3 V3 EDLQ016CA 3 V3 EDLQ011CA 3 W1 EDLQ014CA 3 W1 EDLQ016CA 3 W1 ...

Page 2: ...cumentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentat...

Page 3: ...are on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying ac...

Page 4: ... the indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switched the permission level to Advanced end user Prerequisite You switched the space operation mode to automatic 1 Go to 7 5 User settings Allowed operation mode 2 Select a month and press 3 Selec...

Page 5: ...night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in scheduled mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats...

Page 6: ...gs Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and t...

Page 7: ...gy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater perm...

Page 8: ...e heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too ...

Page 9: ... in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the room temperature schedule The desired room temperature cannot be reached Increase the desired leaving water temperature in accordance with ...

Page 10: ...e backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 8 Glossary DHW Domest...

Page 11: ......

Page 12: ...4P537989 1 2018 05 Copyright 2018 Daikin 4P537989 1 0000000 ...

Reviews: