background image

3 Operation

Operation manual

6

EBLQ+EDLQ011~016CA(3)V3+W1

Daikin Altherma low temperature monobloc

4P537989-1 – 2018.05

3.5

Advanced usage

3.5.1

About changing the user permission level

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ End user (= default)

▪ Adv. end user: You can read out more information.

To set the user permission level to Advanced end user

1

Go to the main menu or any of its submenus: 

.

2

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu title.
The  user  permission  level  will  stay  in  Adv.  end  user  until  set
otherwise.

To set the user permission level to End user

1

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  End  user.  The  user

interface will return to the default home screen.

3.6

Schedules: Example

INFORMATION

The procedures to program other schedules are similar.

In this example:

▪ Room temperature schedule in heating mode

▪ Monday = Tuesday = Wednesday = Thursday = Friday

▪ Saturday = Sunday

To program the schedule

1

Go  to  [7.3.1.1]: 

  >  User  settings  >  Set  schedules  >  Room

temp. > Set heating schedule.

2

Select Empty and press 

.

3

Program the schedule for Monday. See below for more details.

4

Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and
Friday. See below for more details.

5

Program the schedule for Saturday.

6

Copy from Saturday to Sunday.

7

Save  the  schedule  and  give  it  a  name.  See  below  for  more
details.

To program the schedule for Monday

1

Use 

 and 

 to select Monday.

2

Press 

 to enter the schedule for Monday.

3

Program the schedule for Monday:

▪ Use 

 and 

 to select an entry.

▪ Use 

 and 

 to change the value of an entry.

To copy from one day to another

1

Select  the  day  from  which  you  want  to  copy  and  press 

.

Example: 

Monday.

2

Select Copy day and press 

.

3

Set the days you want to copy to Yes and press 

Example:

Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.

To save the schedule

1

Press 

, select Save schedule and press 

.

2

Select  User  defined  1,  User  defined  2  or  User  defined  3  and
press 

.

3

Change  the  name  and  press 

.  (Only  applicable  for  room

temperature schedules). 

Example: 

MyWeekSchedule

To select which schedule you currently want to use

1

Go to [5]: 

 > Select schedules.

2

Select for which control you want to use a schedule. 

Example:

[5.1] Room temperature.

3

Select  for  which  operation  mode  you  want  to  use  a  schedule.

Example: 

[5.1.1] Heating .

4

Select a predefined or user‑defined schedule and press 

.

Summary of Contents for Altherma EBLQ011-016C3V3

Page 1: ...nobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CA 3 V3 EBLQ014CA 3 V3 EBLQ016CA 3 V3 EBLQ011CA 3 W1 EBLQ014CA 3 W1 EBLQ016CA 3 W1 EDLQ011CA 3 V3 EDLQ014CA 3 V3 EDLQ016CA 3 V3 EDLQ011CA 3 W1 EDLQ014CA 3 W1 EDLQ016CA 3 W1 ...

Page 2: ...cumentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentat...

Page 3: ...are on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying ac...

Page 4: ... the indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switched the permission level to Advanced end user Prerequisite You switched the space operation mode to automatic 1 Go to 7 5 User settings Allowed operation mode 2 Select a month and press 3 Selec...

Page 5: ...night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in scheduled mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats...

Page 6: ...gs Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and t...

Page 7: ...gy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater perm...

Page 8: ...e heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too ...

Page 9: ... in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the room temperature schedule The desired room temperature cannot be reached Increase the desired leaving water temperature in accordance with ...

Page 10: ...e backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 8 Glossary DHW Domest...

Page 11: ......

Page 12: ...4P537989 1 2018 05 Copyright 2018 Daikin 4P537989 1 0000000 ...

Reviews: