3 Operation

Operation manual

4

EBLQ+EDLQ011~016CA(3)V3+W1

Daikin Altherma low temperature monobloc

4P537989-1 – 2018.05

Icon

Description

A malfunction occurred. Press 

 to display more

information about the malfunction.

Weather-dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

Emergency operation is active.

3.3

Space heating/cooling control

3.3.1

Setting the space operation mode

About space operation modes

Depending  on  your  heat  pump  model,  you  have  to  tell  the  system
which space operation mode to use: heating or cooling.

If a… heat pump model

is installed

Then…

Heating/cooling

The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.

Heating only

The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.

To  tell  the  system  which  space  operation  to  use,  you  can  do  the
following:

You can…

Location

Check

 which space operation mode is

currently used

.

Home pages:

▪ Room temperature

▪ Leaving 

water

temperature  (main
+ additional)

Set

 the space operation 

mode

.

Menu structure

Restrict

 when 

automatic changeover

 is

possible.

To set the space operation mode

1

Go to [4]: 

 > Operation mode.

2

Select one of the following options and press 

:

If you select…

Then the space operation mode is…

Heating

Always heating mode.

Cooling

Always cooling mode.

Automatic

Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
taking monthly restrictions into
account.

Note: 

Automatic changeover is only

possible under certain conditions.

To restrict automatic changeover operation mode

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

Prerequisite: 

You switched the space operation mode to automatic.

1

Go to [7.5]: 

 > User settings > Allowed operation mode.

2

Select a month and press 

.

3

Select Heating only, Cooling only or Heating/Cooling, and press

.

3.3.2

Room thermostat control - Using the
room temperature home page

Typical room temperature home pages

Depending on the user profile, the user interface gives you either a
basic  or  a  detailed  home  page.  To  set  the  user  profile,  refer  to
Configuring  user  profile  and  home  pages  in  the  user  reference
guide.

User profile = Basic

User profile = Detailed

15:20

20.0°C

Mon

Room

Actual temperature

15:20

20.0°C

17:30

Actual temperature

Room

Scheduled

Mon

Tue

To read out the actual and desired room
temperature

1

Go to the room temperature home page (Room).

Result: 

You  can  read  out  the  actual  temperature.

20.0°C

Actual temperature

2

Press 

.

Result: 

You  can  read  out  the  desired  temperature.

22.0°C

Desired temperature

To temporarily overrule the room temperature
schedule

1

Go to the room temperature home page (Room).

2

Use 

 or 

 to adjust the temperature.

To change the mode from scheduled to preset
value

Prerequisite: 

User profile = Detailed.

1

Go to the room temperature home page (Room).

2

Press 

 or 

 to select a preset value (  or  ).

Result: 

The mode will return to Scheduled according to the overrule

period.

To set the overrule period

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [7.2]: 

 > User settings > Temperature lock.

2

Select a value and press 

:

▪ Permanent
▪ hours (2, 4, 6, 8)

Summary of Contents for Altherma EBLQ011-016C3V3

Page 1: ...nobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CA 3 V3 EBLQ014CA 3 V3 EBLQ016CA 3 V3 EBLQ011CA 3 W1 EBLQ014CA 3 W1 EBLQ016CA 3 W1 EDLQ011CA 3 V3 EDLQ014CA 3 V3 EDLQ016CA 3 V3 EDLQ011CA 3 W1 EDLQ014CA 3 W1 EDLQ016CA 3 W1 ...

Page 2: ...cumentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentat...

Page 3: ...are on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying ac...

Page 4: ... the indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switched the permission level to Advanced end user Prerequisite You switched the space operation mode to automatic 1 Go to 7 5 User settings Allowed operation mode 2 Select a month and press 3 Selec...

Page 5: ...night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in scheduled mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats...

Page 6: ...gs Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and t...

Page 7: ...gy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater perm...

Page 8: ...e heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too ...

Page 9: ... in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the room temperature schedule The desired room temperature cannot be reached Increase the desired leaving water temperature in accordance with ...

Page 10: ...e backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 8 Glossary DHW Domest...

Page 11: ......

Page 12: ...4P537989 1 2018 05 Copyright 2018 Daikin 4P537989 1 0000000 ...

Reviews: