7 Disposal

Operation manual

10

EBLQ+EDLQ011~016CA(3)V3+W1

Daikin Altherma low temperature monobloc

4P537989-1 – 2018.05

Possible cause

Corrective action

Heat pump is damaged.

▪ Press 

 to view a description

of the problem.

▪ Press 

 again.

▪ Select 

  to  allow  the  backup

heater  to  take  over  the  heat
load.

▪ Call  your  local  dealer  to  get

the heat pump fixed.

INFORMATION

When  the  backup  heater  or  booster  heater  takes  over  the
heat  load,  electricity  consumption  will  be  considerably
higher.

7

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

8

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Summary of Contents for Altherma EBLQ011-016C3V3

Page 1: ...nobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CA 3 V3 EBLQ014CA 3 V3 EBLQ016CA 3 V3 EBLQ011CA 3 W1 EBLQ014CA 3 W1 EBLQ016CA 3 W1 EDLQ011CA 3 V3 EDLQ014CA 3 V3 EDLQ016CA 3 V3 EDLQ011CA 3 W1 EDLQ014CA 3 W1 EDLQ016CA 3 W1 ...

Page 2: ...cumentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentat...

Page 3: ...are on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying ac...

Page 4: ... the indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You switched the permission level to Advanced end user Prerequisite You switched the space operation mode to automatic 1 Go to 7 5 User settings Allowed operation mode 2 Select a month and press 3 Selec...

Page 5: ...night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the domestic hot water control is the same as in scheduled mode However when the DHW tank temperature drops below a preset value reheat tank temperature hysteresis value example 35 C the DHW tank heats...

Page 6: ...gs Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and t...

Page 7: ...gy metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Allowed operation mode Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules Room temp LWT main LWT additional DHW temp Booster heater perm...

Page 8: ...e heating cooling and capacity shortage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Default Fill in Contact helpdesk number 4 Energy saving tips Tips about room temperature Make sure the desired room temperature is NEVER too high in heating mode or too ...

Page 9: ... in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Adjust the room temperature schedule The desired room temperature cannot be reached Increase the desired leaving water temperature in accordance with ...

Page 10: ...e backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 8 Glossary DHW Domest...

Page 11: ......

Page 12: ...4P537989 1 2018 05 Copyright 2018 Daikin 4P537989 1 0000000 ...

Reviews: