background image

3 Operation

Operation manual

6

EABH/X16DA+9W + EAVH/X16S(U)18+9W

Daikin Altherma 3 H F+W

4P556068-2A – 2019.12

3.3

Turning operation ON or OFF

3.3.1

Visual indication

Certain  functionalities  of  the  unit  can  be  enabled  or  disabled
separately.  If  a  functionality  is  disabled,  the  corresponding
temperature icon in the home screen will be greyed out.

Room temperature control

1.6

bar

55

19

42

18

a

1.6

bar

55

19

42

18

b

a

Room temperature control ON

b

Room temperature control OFF

Space heating/cooling operation

1.6

bar

55

19

42

18

c

1.6

bar

55

19

42

18

d

c

Space heating/cooling operation ON

d

Space heating/cooling operation OFF

Tank heating operation

1.6

bar

55

19
42

18

e

1.6

bar

55

19
42

18

f

a

Tank heating operation ON

b

Tank heating operation OFF

3.3.2

To turn ON or OFF

Room temperature control

1

Go to [C.1]: 

Operation

 > 

Room

.

Operation

Room

Space heating/cooling

On

On

C.1

2

Set operation to 

On

 or 

Off

.

Space heating/cooling operation

NOTICE

Room  frost  protection.

  Even  if  you  turn  OFF  space

heating/cooling  operation  ([C.2]: 

Operation

  > 

Space

heating/cooling

), room frost protection –if enabled– will

remain active.

NOTICE

Water  pipe  freeze  prevention.

  Even  if  you  turn  OFF

space  heating/cooling  operation  ([C.2]: 

Operation

  >

Space heating/cooling

), water pipe freeze prevention –

if enabled– will remain active.

1

Go to [C.2]: 

Operation

 > 

Space heating/cooling

.

Operation

Space heating/cooling

Tank

Off

On

On

Room

C.2

2

Set operation to 

On

 or 

Off

.

Tank heating operation

NOTICE

Disinfection  mode

.  Even  if  you  turn  OFF  tank  heating

operation ([C.3]: 

Operation

 > 

Tank

), disinfection mode will

remain  active.  However,  if  you  turn  it  OFF  while
disinfection is running, an AH error occurs.

1

Go to [C.3]: 

Operation

 > 

Tank

.

Operation

Tank

Off

On

Space heating/cooling

C.3

2

Set operation to 

On

 or 

Off

.

3.4

Space heating/cooling control

3.4.1

Setting the space operation mode

About space operation modes

Your unit can be a heating or a heating/cooling model:

▪ If your unit is a heating model, it can heat up a space.

▪ If your unit is a heating/cooling model, it can both heat up and cool

down a space. You have to tell the system which operation mode
to use.

To tell the system which space operation to use, you can:

You can…

Location

Check which space operation mode is
currently used.

Home screen

Set the space operation mode permanently. Main menu

Restrict automatic changeover according to
a monthly schedule.

Summary of Contents for Altherma EABH16DA9W

Page 1: ...ish Operation manual Daikin Altherma 3 H F W EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V G EAVH16SU18DA6V EAVH16S23DA6V G EAVH16SU23DA6V EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EAVX16S23DA6V G EAVX16S18DA9W G EAVX16S23DA9W G ...

Page 2: ... documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documen...

Page 3: ...Continuous blue Operation The unit is in operation Blinking red Malfunction A malfunction occurred See 6 1 To display the help text in case of a malfunction 413 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display The time of non interact...

Page 4: ...tdoor unit a2 a3 a1 a1 Outdoor unit a2 Quiet mode active a3 Measured ambient temperature Indoor unit domestic hot water tank b1 b2 b1 Indoor unit Floor standing indoor unit with integrated tank Wall mounted indoor unit with separated tank Wall mounted indoor unit b2 Water pressure Space operation mode c Cooling Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date...

Page 5: ...e domestic hot water tank temperature 7 User settings Gives access to user settings such as holiday mode and quiet mode 8 Information Displays data and information about the indoor unit 9 Installer settings Restriction Only for the installer Gives access to advanced settings A Commissioning Restriction Only for the installer Perform tests and maintenance B User profile Change the active user profi...

Page 6: ...ction if enabled will remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On On Room C 2 2 Set operation to On or Off Tank heating operation NOTICE Disinfection mode Eve...

Page 7: ...room temperature The temperature will stay the same as long as there is no scheduled action The desired room temperature will return to its scheduled value whenever a scheduled action occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 3 4 3 To change the desired leaving water temperature INFOR...

Page 8: ...35 C the DHW tank heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1 2 4 5 3 Tt Domestic hot water tank temperature t Time 3 5 4 Using DHW powerful operation About powerful operation Powerful operation allows the domestic hot water to be heated by the b...

Page 9: ...e 2 Set scheduling to Yes 3 Go to 1 2 Room Heating schedule To clear the content of the week schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of which you want to clear the content For example Friday Mon Sat Wed Fri Thu Tue Sun User define...

Page 10: ... and edit the entry with the right dial 0 8 00 23 00 21 C 18 C 12 24 Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule 1 Select the name of the current schedule Mon Sat Wed Fri Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule nam...

Page 11: ...7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection status B User profile C Operation Room Space heating cooling Tank 1 4 Antifrost Activation Room setpoint 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours...

Page 12: ...a couple of hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Comfort higher DHW tank temperature during the night because then space heating demand is lower If heating up the DHW tank once at night is not sufficient program to ...

Page 13: ... Malfunctioning Result A short description of the error and the error code is displayed on the screen 2 Press in the error screen Result A long description of the error is displayed on the screen 6 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 3 4 2 To chang...

Page 14: ...ooster heater takes over the heat load electricity consumption will be considerably higher 6 5 Symptom The system is making gurgling noises after commissioning Possible cause Corrective action There is air in the system Purge air from the system a Various malfunctions Check if or is displayed on the home screen of the user interface See 6 1 To display the help text in case of a malfunction 413 for...

Page 15: ......

Page 16: ...4P556068 2A 2019 12 Copyright 2019 Daikin 4P556068 2 A 00000001 Verantwortung für Energie und Umwelt ...

Reviews: