background image

3 Operation

Operation manual

3

EABH/X16DA+9W + EAVH/9W
Daikin Altherma – Low temperature split
4P556068-1 – 2018.10

2.1

Components in a typical system
layout

d

a

b

c

e

f

g

B

C

A

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface used as room thermostat

f

Underfloor heating

g

Radiators, heat pump convectors, or fan coil units

INFORMATION

The  indoor  unit  and  the  domestic  hot  water  tank  (if
installed) can be separated or integrated depending on the
indoor unit type.

3

Operation

3.1

User interface: Overview

The user interface has the following components:

b

c

a

a

b

c

a

Status indicator

b

LCD screen

c

Dials and buttons

Status indicator

The  LEDs  of  the  status  indicator  light  up  or  blink  to  show  the
operating mode of the unit.

LED

Mode

Description

Blinking blue

Standby

The unit is not in operation.

Continuous blue Operation

The unit is in operation.

Blinking red

Malfunction

A malfunction occurred.

See 

"6.1 To display the help text

in case of a malfunction" on
page 11

 for more information.

LCD screen

The LCD screen has a sleeping function. After a certain time of non-
interaction with the user interface, the screen darkens. Pressing any
button  or  rotating  any  dial  awakens  the  display.  The  time  of  non-
interaction differs depending on the user permission level:

▪ User or Advanced user: 15 min

▪ Installer: 1 h

Dials and buttons

You use the dials and buttons:

▪ To navigate through the screens, menus and settings of the LCD

screen

▪ To set values

a

b

c

d

e

Item

Description

a

Left dial

The LCD shows an arc on the left side of the
display when you can use the left dial.

: Turn, then press the left dial. Navigate

through the menu structure.

: Turn the left dial. Choose a menu item.

: Press the left dial. Confirm your choice

or go to a submenu.

b

Back button

: Press to go back 1 step in the menu structure.

c

Home
button

: Press to go back to the home screen.

d

Help button

: Press to show a help text related to the current

page (if available).

e

Right dial

The LCD shows an arc on the right side of the
display when you can use the right dial.

: Turn, then press the right dial. Change

a value or setting, shown at the right side of the
screen.

:  Turn  the  right  dial.  Navigate  through

the possible values and settings.

:  Press  the  right  dial.  Confirm  your

choice and go to the next menu item.

3.2

Possible screens: Overview

The most common screens are as follows:

Summary of Contents for Altherma EABH16DA6V

Page 1: ...ure split English Operation manual Daikin Altherma Low temperature split EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V G EAVH16S23DA6V G EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EAV...

Page 2: ...he settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End us...

Page 3: ...11 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial aw...

Page 4: ...ption Space operation mode c Cooling Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Current date and time Holiday f Holiday mode active Main zone g3 g1...

Page 5: ...Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically apply the desired temperature Item Description Minimum temperature limit a1 Fixed by the...

Page 6: ...desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the setpoint screen 2 Adjust the desired l...

Page 7: ...m left to right Browse through the list of digits and change the selected digit Confirm the pincode and proceed User pin code The User pin code is 0000 Advanced user pin code The Advanced user pin cod...

Page 8: ...days Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry w...

Page 9: ...ings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electric...

Page 10: ...longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a...