background image

3 Operation

Operation manual

4

EABH/X16DA+9W + EAVH/9W

Daikin Altherma – Low temperature split

4P556068-1 – 2018.10

+

a

b

c

c2

c1

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

3.2.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

18 Feb 2018

22:19

55

18

21
45

f

i

j

h

g

e

d

a

b

c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

21

21

The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.

Outdoor
unit

a2 a3

a1

a1

: Outdoor unit

a2

: Quiet mode active

a3

Measured ambient temperature

Indoor unit /
domestic
hot water
tank

b1

b2

b1

Indoor unit:

Floor-standing 

indoor 

unit 

with

integrated tank

: Wall-mounted indoor unit with separated

tank

: Wall-mounted indoor unit

b2

Water pressure

Item

Description

Space
operation
mode

c

: Cooling

: Heating

Disinfection
 / Powerful

d

: Disinfection mode active

: Powerful operation active

Date / time

e

Current date and time

Holiday

f

: Holiday mode active

Main zone

g3
g1

g4
g2

g1

Heat emitter type:

: Underfloor heating

: Fancoil unit

: Radiator

g2

Leaving water temperature setpoint

g3

Room thermostat type:

:  Daikin  user  interface  used  as  room

thermostat

: External control

▪ Hidden: Leaving water temperature control

g4

Measured room temperature

Additional
zone

h3
h1 h2

h1

Heat emitter type:

: Underfloor heating

: Fancoil unit

: Radiator

h2

Leaving water temperature setpoint

h3

Room thermostat type:

: External control

▪ Hidden: Leaving water temperature control

Domestic
hot water

i1 i2

i1

: Domestic hot water

i2

Measured tank temperature

Malfunction

j

 or 

: A malfunction occurred

See 

"6.1 To display the help text in case of a

malfunction" on page 11

 for more information.

3.2.2

Main menu screen

In the home screen, press 

 to open the main menu screen.

From the main menu, you can access the different setpoint screens
and submenus.

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Item

Description

 or 

Malfunctioning

Restriction: 

Only displayed if a malfunction

occurs.

See 

"6.1 To display the help text in case of

a malfunction" on page 11

 for more

information.

Summary of Contents for Altherma EABH16DA6V

Page 1: ...ure split English Operation manual Daikin Altherma Low temperature split EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V G EAVH16S23DA6V G EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EAV...

Page 2: ...he settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End us...

Page 3: ...11 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial aw...

Page 4: ...ption Space operation mode c Cooling Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Current date and time Holiday f Holiday mode active Main zone g3 g1...

Page 5: ...Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically apply the desired temperature Item Description Minimum temperature limit a1 Fixed by the...

Page 6: ...desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the setpoint screen 2 Adjust the desired l...

Page 7: ...m left to right Browse through the list of digits and change the selected digit Confirm the pincode and proceed User pin code The User pin code is 0000 Advanced user pin code The Advanced user pin cod...

Page 8: ...days Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry w...

Page 9: ...ings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electric...

Page 10: ...longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a...

Page 11: ...desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of un...

Page 12: ...ging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes mak...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P556068 1 2018 10 Copyright 2018 Daikin 4P556068 1 0000000S...

Reviews: