background image

3 Operation

Operation manual

6

EABH/X16DA+9W + EAVH/9W

Daikin Altherma – Low temperature split

4P556068-1 – 2018.10

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to Automatic.

1

Go to [4.2]: Space heating/cooling > Operation mode
schedule.

2

Select a month.

3

For each month, select an option:

▪ Reversible: Not restricted

▪ Heating only: Restricted

▪ Cooling only: Restricted

4

Confirm the changes.

3.3.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to [1]: Room.

You can read out the desired and actual room
temperature in the center of the setpoint screen.

2

Adjust the desired room temperature.

If scheduling is on after changing the desired room temperature

▪ The  temperature  will  stay  the  same  as  long  as  there  is  no

scheduled action.

▪ The  desired  room  temperature  will  return  to  its  scheduled  value

whenever a scheduled action occurs.

You  can  avoid  scheduled  behaviour  by  (temporarily)  turning  off
scheduling.

To turn off room temperature scheduling

1

Go to [1.1]: Room > Schedule.

2

Select No.

3.3.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

1

Go to [2]: Main zone or [3]: Additional zone.

You can read out the desired and actual leaving
water temperature in the center of the setpoint
screen.

2

Adjust the desired leaving water temperature.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  the  DHW  tank  continuously  heats  up  to  the
temperature shown on the home screen (example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

DHW tank temperature

t

Time

INFORMATION

Risk  of  space  heating  capacity  shortage  for  domestic  hot
water  tank  without  internal  booster  heater:  In  case  of
frequent  domestic  hot  water  operation,  frequent  and  long
space  heating/cooling  interruption  will  happen  when
selecting the following:

Tank > Heat up mode > Reheat only.

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating/cooling  function
is regularly interrupted.

3.4.2

Scheduled mode

In scheduled mode the DHW tank produces hot water corresponding
to a schedule. The best time to allow the tank to produce hot water is
at night, because the space heating demand is lower.

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

3.4.3

Sch reheat mode

In  scheduled  +  reheat  mode,  the  domestic  hot  water  control  is  the
same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

DHW tank temperature

t

Time

Summary of Contents for Altherma EABH16DA6V

Page 1: ...ure split English Operation manual Daikin Altherma Low temperature split EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V G EAVH16S23DA6V G EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EAV...

Page 2: ...he settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End us...

Page 3: ...11 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial aw...

Page 4: ...ption Space operation mode c Cooling Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Current date and time Holiday f Holiday mode active Main zone g3 g1...

Page 5: ...Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically apply the desired temperature Item Description Minimum temperature limit a1 Fixed by the...

Page 6: ...desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the setpoint screen 2 Adjust the desired l...

Page 7: ...m left to right Browse through the list of digits and change the selected digit Confirm the pincode and proceed User pin code The User pin code is 0000 Advanced user pin code The Advanced user pin cod...

Page 8: ...days Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry w...

Page 9: ...ings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electric...

Page 10: ...longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a...

Page 11: ...desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of un...

Page 12: ...ging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes mak...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P556068 1 2018 10 Copyright 2018 Daikin 4P556068 1 0000000S...

Reviews: