Symptom: The system is making
gurgling noises after
commissioning

Possible cause

Corrective action

There is air in the system.

Purge air from the system.

(a)

Various malfunctions.

Check if 

 or 

 is displayed

on the home screen of the user
interface. See 

"6.1 To display the

help text in case of a
malfunction" on page 11

 for more

information about the
malfunction.

(a)

We recommend to purge air with the unit's air purge
function (to be performed by the installer). If you purge air
from the heat emitters or collectors, mind the following:

WARNING

Air  purging  heat  emitters  or  collectors.

  Before  you

purge  air  from  heat  emitters  or  collectors,  check  if 

  or

 is displayed on the home screen of the user interface.

▪ If not, you can purge air immediately.

▪ If  yes,  make  sure  that  the  room  where  you  want  to

purge air is sufficiently ventilated. 

Reason:

 Refrigerant

might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.

7

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  dismantling
of  the  system,  treatment  of  the  refrigerant,  oil  and  other
parts  MUST  comply  with  applicable  legislation.  Units
MUST  be  treated  at  a  specialised  treatment  facility  for
reuse, recycling and recovery.

8

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Summary of Contents for Altherma EABH16DA6V

Page 1: ...ure split English Operation manual Daikin Altherma Low temperature split EABH16DA6V EABH16DA9W EABX16DA6V EABX16DA9W EAVH16S18DA6V G EAVH16S23DA6V G EAVH16S18DA9W G EAVH16S23DA9W G EAVX16S18DA6V G EAV...

Page 2: ...he settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End us...

Page 3: ...11 for more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial aw...

Page 4: ...ption Space operation mode c Cooling Heating Disinfection Powerful d Disinfection mode active Powerful operation active Date time e Current date and time Holiday f Holiday mode active Main zone g3 g1...

Page 5: ...Possible actions on this screen Go through the list of the submenu Go to the submenu Adjust and automatically apply the desired temperature Item Description Minimum temperature limit a1 Fixed by the...

Page 6: ...desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone You can read out the desired and actual leaving water temperature in the center of the setpoint screen 2 Adjust the desired l...

Page 7: ...m left to right Browse through the list of digits and change the selected digit Confirm the pincode and proceed User pin code The User pin code is 0000 Advanced user pin code The Advanced user pin cod...

Page 8: ...days Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select an entry and edit the entry w...

Page 9: ...ings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electric...

Page 10: ...longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a...

Page 11: ...desired leaving water temperature in accordance with the heat emitter type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of un...

Page 12: ...ging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes mak...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...4P556068 1 2018 10 Copyright 2018 Daikin 4P556068 1 0000000S...

Reviews: