2 Specific installer safety instructions
Installation manual
5
EBBH/X11+16DF
Daikin Altherma 3 R W
4P643600-1B – 2021.10
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
Online tools
In addition to the documentation set, some online tools are available
for installers:
▪
Daikin Technical Data Hub
▪ Central hub for technical specifications of the unit, useful tools,
digital resources, and more.
▪ Publicly accessible via
https://daikintechnicaldatahub.eu
.
▪
Heating Solutions Navigator
▪ Digital toolbox that offers a variety of tools to facilitate the
installation and configuration of heating systems.
▪ To access Heating Solutions Navigator, registration to the
Stand By Me platform is required. For more information, see
https://professional.standbyme.daikin.eu
.
▪
Daikin e-Care
▪ Mobile app for installers and service technicians that allows you
to register, configure and troubleshoot heating systems.
▪ The mobile app can be downloaded for iOS and Android
devices using the QR codes below. Registration to the Stand
By Me platform is required to access the app.
App Store
Google Play
2
Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation site (see
"4.1 Preparing the installation site"
[
4
6])
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
WARNING
DO NOT reuse refrigerant piping that has been used with
any other refrigerant. Replace the refrigerant pipes or
clean thoroughly.
WARNING
Follow the service space dimensions in this manual for
correct installation of the unit. See
"4.1.1 Installation site
requirements of the indoor unit"
[
4
6].
Special requirements for R32 (see
"4.1.2 Special requirements
for R32 units"
[
4
7])
WARNING
▪ Do NOT pierce or burn.
▪ Do NOT use means to accelerate the defrosting
process or to clean the equipment, other than those
recommended by the manufacturer.
▪ Be aware that R32 refrigerant does NOT contain an
odour.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (example: open flames, an
operating gas appliance or an operating electric heater).
WARNING
Make sure installation, servicing, maintenance and repair
comply with instructions from Daikin and with applicable
legislation and are executed ONLY by authorised persons.
Opening and closing the unit (see
"4.2 Opening and closing the
unit"
[
4
13])
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
Mounting the indoor unit (see
"4.3 Mounting the indoor
unit"
[
4
14])
WARNING
Fixing method of the indoor unit MUST be in accordance
with the instructions from this manual. See
"4.3 Mounting
the indoor unit"
[
4
14].
Piping installation (see
"5 Piping installation"
[
4
15])
WARNING
Field piping method MUST be in accordance with the
instructions
from
this
manual.
See
"5
Piping
installation"
[
4
15].
Electrical installation (see
"6 Electrical installation"
[
4
17])
DANGER: RISK OF ELECTROCUTION
WARNING
Electrical wiring connection method MUST be in
accordance with the instructions from:
▪ This manual. See
"6 Electrical installation"
[
4
17].
▪ The wiring diagram, which is delivered with the unit,
located on the inside of the indoor unit switch box
cover. For a translation of its legend, see
"10.2 Wiring
diagram: Indoor unit"
[
4
41].
WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
legislation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction MUST comply with the applicable
legislation.
All manuals and user guides at all-guides.com