11
Installation
Installation
Pr
ocedure
Normal
Normal or power failure
Alarm or power failure
Alarm
60
61
63
60
61
63
60
61
63
60
61
63
The contact capacity is as follows:
Resistance load: 30 VDC, 2 A
The minimum allowable load is as follows:
10
µ
A, 10 mV
To connect an inductive load, be sure to use a
surge absorber.
CAUTION
To output the Oil Cooling Unit operation status signal to the main machine, connect the required signal cable to the signal
terminal block according to the procedure below. For details of alarms, refer to “Alarm list” (page ). For details of warnings,
refer to “Warning list” (page ).
To use an output contact, change the parameter setting, and make sure that the output contact normally operates.
(For parameter setting changing procedure, refer to page .)
External output circuit
Alarm and warning output logic
The alarm and warning output logic can be changed
depending on the parameter setting. (See page .)
When the power supply is turned ON,
external output becomes unstable.
Set up the main machine sequence program so that the external
output signal is ignored for one second after power-ON.
Value of the first digit in alarm and warning output logic parameter (n001)
0 (Factory setting)
[Positive action]
1
[“b” contact]
Operation status
Power OFF
(including power failure)
Power ON
Run
Run
Run
Alarm
level 2
Alarm
level 1
Power supply
Remote control
contact
Operation panel
Normal (“a” contact)
Alarm/Stop (Power
OFF) (“b” contact)
Pump run
(“a” contact)
Alarm level
Alarm (“a” contact)
Normal/Stop (Power
OFF) (“b” contact)
Between terminals
60 and 63
Between terminals
60 and 63
Pump run
(“a” contact)
Alarm level
Between terminals
60 and 61
[LOCK] key
Between terminals
10 and 11
Between terminals
61 and 62
Between terminals
60 and 64
Between terminals
60 and 61
Between terminals
61 and 62
Between terminals
60 and 64
Preset condition
Output logic parameter
setting: “0”
Mode and terminal symbol of external output contact
Output logic parameter
setting: “1”
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
Reset
Reset
External output timing chart
1
2
3
Connection of external output contact
1.
Bar-type Terminal and cable size
2.
Connect each cable by using a bar-type crimp terminal.
3.
Use a twisted cable.
4.
When a 2-core IEC cable is used, the cable size should be
0.5 to 1.5 mm
2
.
When you use a stripped wire, strip the
sheath 9 to 10mm from the end of the wire.
Cable size
UL cable
IEC cable
∗
0.25 mm
2
– 1.25 mm
2
0.3 mm
2
– 1.5 mm
2
AWG
#
22 –
#
16
JIS cable
Bar-type
Terminal
(For alarm levels, refer to page .)
26
41
33
39·40
39·40
Remote control
Not used (No connection)
Normal Pump run
Alarm/Power failure
Alarm level output (OFF:Level1, ON:Level2)
Not used (No connection)
Warning
output
60 61 62 63 64 65 66 67
9 10 11 12 13 30 31
Inside of Oil Cooling Unit
(X2M)
MR52P
a
MR30Y
MR30X
MR30W
For connection of
optional protection
device (OP)
For connection of
machine
temperature
tuning thermistor
Cable
9~10mm
∗
Recommended Model (Manufacturer): TGN TC-1.25-9T (Nichifu)
APA-1.25N (Daido Solderless Terminal Mfg.)
PIM00318A_EN.fm Page 11 Tuesday, October 26, 2010 12:37 PM