11 Configuration
INFORMATION
Following field settings are applicable only for direct expansion indoor units (DX). For
the DHW tank field setting, refer to the installation manual of the DHW tank.
In this chapter
11.1 About standby electricity saving function
INFORMATION
This function is available only for the air-conditioning indoor units listed below.
The standby electricity saving function:
▪
turns OFF the power supply to the outdoor unit and,
▪
turns ON the standby electricity saving mode on the indoor unit.
The standby electricity saving function works with following units:
FTXM, FTXJ, FVXM, FTXA, CTXA, CTXM, CVXM
If another indoor unit is used, the connector for standby electric saving MUST be
plugged in.
The standby electricity saving function is turned OFF before shipping.
11.1.1 To turn ON standby electricity saving function
Prerequisite:
The main power supply MUST be turned OFF.
1
Remove the service cover.
2
Disconnect the selective standby electricity saving connector.
3
Turn ON the main power supply.