background image

INSTALLATION
MANUAL

AIR COOLED, DUCTED
SPLIT TYPE  AIR-CONDITIONERS
(D & E SERIES)

IM-CC&SB-D/ER-0412(0)-Daikin

Part No.: R08019037636

English

Français

Deutsch

Italiano

Español

Русский

Türkçe

Installation Manual

Split Type Air Conditioner

Manuel D’installation

Climatiseurs Split System

Installationshandbuch

Doppelfunktions-Klimagerät

Manuale Di Installazione

Condizionatore Split A

Manual De Instalación

Equipo de air Acondicionado 

de tipo Dividido de

Руководство по установке

разделить Кондиционер 

воздуха типа

Kurulum kılavuzu

Split Tipi Klima

R407C Cooling only

FDMP75DXV1

RCP75D(G)XY1

FDMP100DXV1

RCP100D(G)XY1

FDP125DXY1

RCP125D(G)XY1

FDP150DXY1

RCP150D(G)XY1

2FDP150DXY1

RCP75D(G)XY1 x 2

2FDP200DXY1

RCP100D(G)XY1 x 2

2FGP250DXY1

RCP125D(G)XY1 x 2

2FGP300DXY1

RCP150D(G)XY1 x 2

4FGP400DXY1

RCP100D(G)XY1 x 4

4FGP500DXY1

RCP125D(G)XY1 x 4

R407C Heatpump

FDYMP75DXV1

RCYP75E(G)XY1

FDYMP100DXV1 RCYP100E(G)XY1
FDYP125EXY1

RCYP125E(G)XY1

FDYP150EXY1

RCYP150E(G)XY1

2FDYP150EXY1 RCYP75E(G)XY1 x 2
2FDYP200EXY1 RCYP100E(G)XY1 x 2
2FGYP250EXY1 RCYP125E(G)XY1 x 2
2FGYP300EXY1 RCYP150E(G)XY1 x 2
3FGYP300EXY1 RCYP100E(G)XY1 x 3

3FGYP350EXY1

RCYP100E(G)XY1
RCYP125E(G)XY1 x 2

4FGYP400EXY1 RCYP100E(G)XY1 x 4
3FGYP450EXY1 RCYP150E(G)XY1 x 3
4FGYP500EXY1 RCYP125E(G)XY1 x 4
4FGYP600EXY1 RCYP150E(G)XY1 x 4

MODELS

R22 Cooling only

FDM75DXV1

RC75D(G)XY1

FDM100DXV1

RC100D(G)XY1

FD125DXY1

RC125D(G)XY1

FD150DXY1

RC150D(G)XY1

2FD150DXY1

RC75D(G)XY1 x 2

2FD200DXY1

RC100D(G)XY1 x 2

2FG250DXY1

RC125D(G)XY1 x 2

2FG300DXY1

RC150D(G)XY1 x 2

4FG400DXY1

RC100D(G)XY1 x 4

4FG500DXY1

RC125D(G)XY1 x 4

R22 Heatpump

FDYM75DXV1

RCY75E(G)XY1

FDYM100DXV1 RCY100E(G)XY1
FDY125EXY1

RCY125E(G)XY1

FDY150EXY1

RCY150E(G)XY1

2FDY150EXY1 RCY75E(G)XY1 x 2
2FDY200EXY1 RCY100E(G)XY1 x 2
2FGY250EXY1 RCY125E(G)XY1 x 2
2FGY300EXY1 RCY150E(G)XY1 x 2
3FGY300EXY1 RCY100E(G)XY1 x 3

3FGY350EXY1

RCY100E(G)XY1
RCY125E(G)XY1 x 2

4FGY400EXY1 RCY100E(G)XY1 x 4
3FGY450EXY1 RCY150E(G)XY1 x 3
4FGY500EXY1 RCY125E(G)XY1 x 4
4FGY600EXY1 RCY150E(G)XY1 x 4

CVR-IM-CC&SB-D-ER-0412(0) DAIKIN1   1

CVR-IM-CC&SB-D-ER-0412(0) DAIKIN1   1

7/18/12   2:30:08 PM

7/18/12   2:30:08 PM

Summary of Contents for 2FD150DXY1

Page 1: ...YP150EXY1 RCYP150E G XY1 2FDYP150EXY1 RCYP75E G XY1 x 2 2FDYP200EXY1 RCYP100E G XY1 x 2 2FGYP250EXY1 RCYP125E G XY1 x 2 2FGYP300EXY1 RCYP150E G XY1 x 2 3FGYP300EXY1 RCYP100E G XY1 x 3 3FGYP350EXY1 RCY...

Page 2: ......

Page 3: ...s are in mm Original Instruction Dimension Model A B C D E F G H I J K L 75D 1120 1264 336 699 336 1370 710 746 103 53 63 56 100D 1349 1493 331 940 328 1599 710 746 103 53 60 56 Dimension Model M N O...

Page 4: ...4 1654 590 1794 54 114 48 20 680 474 70 89 150D 150E 1805 2033 1933 730 2073 54 114 48 20 680 474 70 89 Dimension Model N O P Q R S T U V W X Y 125D 125E 408 213 25 1009 104 130 215 89 35 710 125 305...

Page 5: ...sion Model A B C D E F G H I J K L M 150D 150E 1805 2033 1933 730 474 20 48 680 54 114 2073 70 408 Dimension Model N O P Q R S T U V W X Y Z 150D 150E 89 213 25 1014 109 215 130 710 89 35 60 245 187 I...

Page 6: ...982 1011 300D 1226 1501 1461 1381 1129 1552 1405 482 841 982 1214 Dimension Model L M N O P Q R S T U V 200D 678 301 295 474 796 1324 60 22 130 150 25 250D 779 353 333 560 897 1486 60 22 130 150 25 3...

Page 7: ...1 1742 1596 816 1405 185 150 130 1462 60 500D 2047 2007 1927 2098 1952 1172 1760 185 150 130 1462 60 Dimension Model M N O P Q R S T U V W X 400D 1367 25 1090 695 384 1722 273 358 698 972 1175 22 500D...

Page 8: ...sions are in mm Dimension Model A B C D E F G H I J K L 200E 1624 1834 1794 1040 48 754 117 53 50 20 660 474 Dimension Model M N O P Q R S T U V W X 200E 257 408 220 885 35 130 850 60 193 103 747 1894...

Page 9: ...22 2122 560 731 542 407 286 50 55 48 400 450 500E 2234 2004 1271 1451 1556 2174 2274 694 740 758 407 286 50 55 48 Dimension Model P Q R S T U V W X Y Z ZA ZB 250 300E 20 1196 35 528 482 60 129 1069 13...

Page 10: ...74 20 48 1679 50 55 115 1978 60 Dimension Model O P Q R S T U V W X Y Z ZA ZB ZB 600E 1775 130 286 35 1758 38 90 129 1883 1905 939 736 100 850 NOTE FOR VERTICAL AIR DISCHARGE X S T V U E C G G B K L D...

Page 11: ...5 100 125 150D RCY P 75 100 125 150E Dimension Model A B C D E F G H I 75 100D 75 100E 571 396 350 981 946 1041 200 95 50 125D 150E 673 396 350 1083 946 1041 200 95 50 150D 150E 673 493 354 1083 1047...

Page 12: ...going into suction of the unit This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage fluctuates greatly Do not install the units at area like hot spring or...

Page 13: ...of fan coil unit is level in the two horizontal directions taking into account the gradient recommended for drainage flow as shown Check the gradient recommended for drainage flow as follow Provide c...

Page 14: ...lace where the unit will not be buried in snow A place where air outlet port is not exposed to strong wind A place where the air discharge and operating sound level will not annoy the neighbours The l...

Page 15: ...gfromthefaceoftheswaging block is determined by the flaring tool See Figure III Fix the pipe firmly on the swaging block Match the centers of both the flare die and the flaring punch and tighten flari...

Page 16: ...ck Outdoor Unit Terminal Block Power Supply Cable Power Supply Cable FD P 125 150D IMPORTANT These values are for information only they should be checked and selected to comply with the local and or n...

Page 17: ...2 Circuit multiply according to the number of outdoor units Model Indoor 2FD P 150D 2FD P 200D 2FG P 250D 2FG P 300D 4FG P 400D 4FG P 500D Outdoor RC P x 2 RC P 100D x 2 RC P 125D x 2 RC P 150D x 2 R...

Page 18: ...nductors A Indoor B Outdoor 1 2 5 2 5 5 1 4 4 5 Interconnection cable size mm Number of conductors 1 7 1 7 Recommended time delay fuse A A Indoor B Outdoor C Total 10 25 32 12 40 40 FDY P 125 150E R S...

Page 19: ...Y P 250E 2FGY P 300E 3FGY P 350E 4FGY P 400E 4FGY P 500E Outdoor RCY P 75E x 2 RCY P 100E x 2 RCY P 125E x 2 RCY P 150E x 2 RCY P 100E RCY P 125E x 2 RCY P 100E x 4 RCY P 125E x 4 Voltage range Indoor...

Page 20: ...oners This is to minimise the contamination of moisture and dirt in the refrigerant system Filter dryer must be of molecular sieve type For a heat pump system install a two way flow filter dryer along...

Page 21: ...imately 30 minutes The evacuation time varies with different vacuum pump capacity Confirm that the charging gauge needle has moved towards 760mmHg Caution If the gauge needle does not move to 760mmHg...

Page 22: ...ping length is less than 7 5m then additional charge after vacuuming is not necessary When the piping length is more than 7 5m use the table below R22 R407C Liquid pipe OD Additional charge kg m Addit...

Page 23: ...ich are very effective in preventing dangerously high discharge temperatures during charging The protection module will trip and lock the compressor out for 30 minutes It is not normally necessary to...

Page 24: ...the unit Check the 3 phase wiring R phase missing Switch off the unit Check the 3 phase wiring S T phase missing Switch off the unit Check the 3 phase wiring Overload High discharge temperature Check...

Page 25: ...ditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips TROUBLESHOOTING Fault Causes Action The...

Page 26: ...MEMO...