 WARNING

!

 CAUTION

 Installation and maintenance should be performed by qualified 
persons who are familiar with local code and regulation, and 
experienced with this type of appliance.
 All field wiring must be installed in accordance with the national 
wiring regulation.
 Ensure that the rated voltage of the unit corresponds to that of 
the name plate before commencing wiring work according to the 
wiring diagram.
 The unit must be GROUNDED to prevent possible hazard due 
to insulation failure.
 All electrical wiring must not touch the refrigerant piping, or any 
moving parts of the fan motors.
 Confirm that the unit has been switched OFF before installing 
or servicing the unit.
 Disconnect from the main power supply before servicing the air 
conditioner unit.
 DO NOT pull out the power cord when the power is ON. This may 
cause serious electrical shocks which may result in fire hazards.
 Keep the indoor and outdoor units, power cable and transmission 
wiring, at least 1m from TVs and radios, to prevent distorted pictures 
and static. {Depending on the type and source of the electrical 
waves, static may be heard even when more than 1m away}.

Please take note of the following important points when 
installing.

 Do not install the unit where leakage of flammable gas may 
occur.

If gas leaks and accumulates around the unit, it may cause 
fire ignition.

 Ensure that the drainage piping is connected properly.

If the drainage piping is not connected properly, it may 
cause water leakage which will dampen the furniture.

Do not overcharge the unit.

This unit is factory pre-charged. Overcharge will cause 
over-current or damage to the compressor.

 Ensure that the unit’s panel is closed after service or 
installation.

Unsecured panels will cause the unit to operate noisily.

 Sharp edges and coil surfaces are potential locations which 
may cause injury hazards. Avoid from being in contact with 
these places.
 Before turning off the power supply, set the remote controller’s 
ON/OFF switch to the “OFF” position to prevent the nuisance 
tripping of the unit.

 If this is not done, the unit’s fans will start 

turning automatically when power resumes, posing a hazard to 
service personnel or the user.
Do not install the units at or near doorway.
 Do not operate any heating apparatus too close to the air conditioner 
unit or use in room where mineral oil, oil vapour or oil steam exist, 
this may cause plastic part to melt or deform as a result of excessive 
heat or chemical reaction.
 When the unit is used in kitchen, keep flour away from going into 
suction of the unit.
 This unit is not suitable for factory used where cutting oil mist or 
iron powder exist or voltage fluctuates greatly.
 Do not install the units at area like hot spring or oil refinery plant 
where sulphide gas exists.
 Ensure the color of wires of the outdoor unit and the terminal 
markings are same to the indoors respectively.

 IMPORTANT : DO NOT INSTALL OR USE THE AIR 
CONDITIONER UNIT IN A LAUNDRY ROOM.
 

Don’t use joined and twisted wires for incoming power supply.
 The equipment is not intended for use in a potentially explosive 
atmosphere.



Important information regarding the refrigerant used

This product contains fluorinated greenhouse gases covered by the 
Kyoto Protocol. 
Do not vent gases into the atmosphere.
Refrigerant type:  R407C 
GWP 

(1)

 value: 

1652.5 

(1)

 GWP = global warming potential

Please fill in with indelible ink,

1

 

the factory refrigerant charge of the product,

2

 

the additional refrigerant amount charged in the field and

1

 

2

 

the total refrigerant charge

on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product 
charging port (e.g. onto the inside of the service cover).

1  factory refrigerant charge of the product:
  see unit name plate 

(2)

2  additional refrigerant amount charged in 

the field

3 total refrigerant charge
4  Contains fluorinated greenhouse gases 

covered by the Kyoto Protocol

5 outdoor unit
6  refrigerant cylinder and manifold for 

charging

(2)

 In case of multiple indoor systems, only 1 label must be adhered*, 

mentioning the total factory refrigerant charge of all indoor units 
connected in the refrigerant system.
Periodical inspections for refrigerant leaks may be required depending 
on European or local legislation. Please contact your local dealer for 
more information.
* on the outdoor unit



INSTALLATION MANUAL

SAFETY PRECAUTIONS

This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit.
Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay 
persons.
This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible 
for their safety. 
Children should be supervised to ensure that they do not play with the appliance.

1-IM-CC&SB-D_ER-0412(0)-DAIKIN-E10   10

1-IM-CC&SB-D_ER-0412(0)-DAIKIN-E10   10

7/23/12   2:45:44 PM

7/23/12   2:45:44 PM

Summary of Contents for 2FD150DXY1

Page 1: ...YP150EXY1 RCYP150E G XY1 2FDYP150EXY1 RCYP75E G XY1 x 2 2FDYP200EXY1 RCYP100E G XY1 x 2 2FGYP250EXY1 RCYP125E G XY1 x 2 2FGYP300EXY1 RCYP150E G XY1 x 2 3FGYP300EXY1 RCYP100E G XY1 x 3 3FGYP350EXY1 RCY...

Page 2: ......

Page 3: ...s are in mm Original Instruction Dimension Model A B C D E F G H I J K L 75D 1120 1264 336 699 336 1370 710 746 103 53 63 56 100D 1349 1493 331 940 328 1599 710 746 103 53 60 56 Dimension Model M N O...

Page 4: ...4 1654 590 1794 54 114 48 20 680 474 70 89 150D 150E 1805 2033 1933 730 2073 54 114 48 20 680 474 70 89 Dimension Model N O P Q R S T U V W X Y 125D 125E 408 213 25 1009 104 130 215 89 35 710 125 305...

Page 5: ...sion Model A B C D E F G H I J K L M 150D 150E 1805 2033 1933 730 474 20 48 680 54 114 2073 70 408 Dimension Model N O P Q R S T U V W X Y Z 150D 150E 89 213 25 1014 109 215 130 710 89 35 60 245 187 I...

Page 6: ...982 1011 300D 1226 1501 1461 1381 1129 1552 1405 482 841 982 1214 Dimension Model L M N O P Q R S T U V 200D 678 301 295 474 796 1324 60 22 130 150 25 250D 779 353 333 560 897 1486 60 22 130 150 25 3...

Page 7: ...1 1742 1596 816 1405 185 150 130 1462 60 500D 2047 2007 1927 2098 1952 1172 1760 185 150 130 1462 60 Dimension Model M N O P Q R S T U V W X 400D 1367 25 1090 695 384 1722 273 358 698 972 1175 22 500D...

Page 8: ...sions are in mm Dimension Model A B C D E F G H I J K L 200E 1624 1834 1794 1040 48 754 117 53 50 20 660 474 Dimension Model M N O P Q R S T U V W X 200E 257 408 220 885 35 130 850 60 193 103 747 1894...

Page 9: ...22 2122 560 731 542 407 286 50 55 48 400 450 500E 2234 2004 1271 1451 1556 2174 2274 694 740 758 407 286 50 55 48 Dimension Model P Q R S T U V W X Y Z ZA ZB 250 300E 20 1196 35 528 482 60 129 1069 13...

Page 10: ...74 20 48 1679 50 55 115 1978 60 Dimension Model O P Q R S T U V W X Y Z ZA ZB ZB 600E 1775 130 286 35 1758 38 90 129 1883 1905 939 736 100 850 NOTE FOR VERTICAL AIR DISCHARGE X S T V U E C G G B K L D...

Page 11: ...5 100 125 150D RCY P 75 100 125 150E Dimension Model A B C D E F G H I 75 100D 75 100E 571 396 350 981 946 1041 200 95 50 125D 150E 673 396 350 1083 946 1041 200 95 50 150D 150E 673 493 354 1083 1047...

Page 12: ...going into suction of the unit This unit is not suitable for factory used where cutting oil mist or iron powder exist or voltage fluctuates greatly Do not install the units at area like hot spring or...

Page 13: ...of fan coil unit is level in the two horizontal directions taking into account the gradient recommended for drainage flow as shown Check the gradient recommended for drainage flow as follow Provide c...

Page 14: ...lace where the unit will not be buried in snow A place where air outlet port is not exposed to strong wind A place where the air discharge and operating sound level will not annoy the neighbours The l...

Page 15: ...gfromthefaceoftheswaging block is determined by the flaring tool See Figure III Fix the pipe firmly on the swaging block Match the centers of both the flare die and the flaring punch and tighten flari...

Page 16: ...ck Outdoor Unit Terminal Block Power Supply Cable Power Supply Cable FD P 125 150D IMPORTANT These values are for information only they should be checked and selected to comply with the local and or n...

Page 17: ...2 Circuit multiply according to the number of outdoor units Model Indoor 2FD P 150D 2FD P 200D 2FG P 250D 2FG P 300D 4FG P 400D 4FG P 500D Outdoor RC P x 2 RC P 100D x 2 RC P 125D x 2 RC P 150D x 2 R...

Page 18: ...nductors A Indoor B Outdoor 1 2 5 2 5 5 1 4 4 5 Interconnection cable size mm Number of conductors 1 7 1 7 Recommended time delay fuse A A Indoor B Outdoor C Total 10 25 32 12 40 40 FDY P 125 150E R S...

Page 19: ...Y P 250E 2FGY P 300E 3FGY P 350E 4FGY P 400E 4FGY P 500E Outdoor RCY P 75E x 2 RCY P 100E x 2 RCY P 125E x 2 RCY P 150E x 2 RCY P 100E RCY P 125E x 2 RCY P 100E x 4 RCY P 125E x 4 Voltage range Indoor...

Page 20: ...oners This is to minimise the contamination of moisture and dirt in the refrigerant system Filter dryer must be of molecular sieve type For a heat pump system install a two way flow filter dryer along...

Page 21: ...imately 30 minutes The evacuation time varies with different vacuum pump capacity Confirm that the charging gauge needle has moved towards 760mmHg Caution If the gauge needle does not move to 760mmHg...

Page 22: ...ping length is less than 7 5m then additional charge after vacuuming is not necessary When the piping length is more than 7 5m use the table below R22 R407C Liquid pipe OD Additional charge kg m Addit...

Page 23: ...ich are very effective in preventing dangerously high discharge temperatures during charging The protection module will trip and lock the compressor out for 30 minutes It is not normally necessary to...

Page 24: ...the unit Check the 3 phase wiring R phase missing Switch off the unit Check the 3 phase wiring S T phase missing Switch off the unit Check the 3 phase wiring Overload High discharge temperature Check...

Page 25: ...ditioner unit is noted immediately switch off the power supply to the unit Check the following fault conditions and causes for some simple troubleshooting tips TROUBLESHOOTING Fault Causes Action The...