![background image](http://html1.mh-extra.com/html/daikin/19-series/19-series_specification-sheet_3217193006.webp)
6
www.daikincomfort.com
SS-RKN19
SS-RKN19
www.daikincomfort.com
7
Dimensions — Indoor Units
FTX18NMVJU
45˚
45˚
REAR
BOTTOM
FAN
UP/DOWN (AUTOMATIC)
15˚
65˚
FLAPS
SIGNAL TRANSMITTER
20˚
RIGHT
80˚
65˚
HEATING
RIGHT/LEFT (MANUAL)
25˚
COOLING, DRY
BLADE ANGLES
LEFT
80˚
70˚
35˚
30˚
10˚
55˚
WALL HOLE
φ
3-1/8 (
φ
80mm) HOLE
WALL HOLE FOR EMBEDDED PIPING
φ
3-1/8 (
φ
80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
1-7/8 (48mm)
2-3/8 (60mm)
29-3/8 (746mm)
39 (990mm)
9/16
(14.6mm
)
1-3/4
(44.5mm
)
5 (126.5mm)
1-3/4
(44.5mm
)
11-5/8
(295mm
)
5/16
(7.9mm
)
7-1/16
(180mm
)
1-7/8 (48mm)
13/16 (20mm)
DRAIN HOSE
(CONNECTING PART
I.D.
φ
9/16 (
φ
14mm)
O.D.
φ
5/8 (
φ
16mm)
MODEL NAME PLATE
TIMER LAMP
OPERATION LAMP
INDOOR UNIT ON/OFF SWITCH
SIGNAL RECEIVER
ROOM TEMP. THERMISTOR
(INSIDE)
LIQUID PIPE
φ
1/4 (
φ
6.4mm) CuT
GAS PIPE
φ
1/2 (
φ
12.7mm) CuT
ABOUT 14-3/16 (360mm)
ABOUT 14-3/8 (365mm)
ABOUT 17-3/4 (450mm)
DRAIN HOSE
LIQUID PIPE
GAS PIPE
ABOUT 15-3/4 (400mm)
ABOUT 17-5/16 (440mm)
ABOUT 18-1/8 (460mm)
1-15/16 (50mm) MIN
1-15/16 (50mm) MIN
REQUIRED SPACE
(SPACE FOR
MAINTENANCE)
(SPACE FOR
MAINTENANCE)
1-3/16
(30mm
) MIN
(SPACE FOR PERFORMANCE)
AIR FLOW (INDOOR)
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
1/2
(12mm
)
11-5/8
(295mm
)
FRONT GRILLE FIXING SCREWS
(INSIDE)
10-3/8 (263mm)
10-7/16 (265mm)
(
)
INCLUDING
MOUNTING PLATE
39 (990mm)
THE MARK (
→
) SHOWS PIPING DIRECTION
WIRELESS REMOTE CONTROLLER
(ARC480A8)
3D091779
FTX24NMVJU
1-3/4
(44.5mm
)
1-3/16
(30mm
) MIN
11-5/8
(295mm
)
10-3/8 (263mm)
29-3/8 (746mm)
7-1/16
(180mm
)
39 (990mm)
ABOUT 14-3/16 (360mm)
ABOUT 15-3/4 (400mm)
ABOUT 17-5/16 (440mm)
ABOUT 18-1/8 (460mm)
5 (126.5mm)
1-7/8 (48mm)
39 (990mm)
5/16
(7.9mm
)
ABOUT 14-3/8 (365mm)
1-15/16 (50mm) MIN
1-15/16 (50mm) MIN
10-7/16 (265mm)
1/2
(12mm
)
11-5/8
(295mm
)
1-7/8 (48mm)
9/16
(14.6mm
)
1-3/4
(44.5mm
)
ABOUT 17-3/4 (450mm)
2-3/8 (60mm)
13/16 (20mm)
45˚
45˚
THE MARK (
→
) SHOWS PIPING DIRECTION
REAR
TIMER LAMP
RIGHT/LEFT (MANUAL)
REQUIRED SPACE
DRAIN HOSE
55˚
LIQUID PIPE
φ
1/4 (
φ
6.4mm) CuT
GAS PIPE
φ
5/8 (
φ
15.9mm) CuT
RIGHT
65˚
UP/DOWN (AUTOMATIC)
15˚
SIGNAL TRANSMITTER
25˚
80˚
AIR FLOW (INDOOR)
OPERATION LAMP
20˚
65˚
35˚
80˚
15˚
MODEL NAME PLATE
BLADE ANGLES
BOTTOM
INDOOR UNIT ON/OFF SWITCH
FAN
COOLING, DRY
HEATING
STANDARD LOCATIONS OF WALL HOLES
30˚
LEFT
SIGNAL RECEIVER
10˚
LIQUID PIPE
GAS PIPE
FLAPS
70˚
WALL HOLE FOR EMBEDDED PIPING
φ
3-1/8 (
φ
80mm) HOLE
WALL HOLE
φ
3-1/8 (
φ
80mm) HOLE
DRAIN HOSE
(CONNECTING PART
I.D.
φ
9/16 (
φ
14mm)
O.D.
φ
5/8 (
φ
16mm)
(SPACE FOR
MAINTENANCE)
(SPACE FOR PERFORMANCE)
(SPACE FOR
MAINTENANCE)
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
ROOM TEMP. THERMISTOR
(INSIDE)
FRONT GRILLE FIXING SCREWS
(INSIDE)
(
)
INCLUDING
MOUNTING PLATE
WIRELESS REMOTE CONTROLLER
(ARC480A8)
3D091780