background image

4

www.daikincomfort.com

SS-RKN19

SS-RKN19

www.daikincomfort.com

5

Dimensions — Indoor Units

FTK09/12NMVJU

30-5/16 (770 mm)

21-1/8 (536.6 mm)

1-15/16 (50 mm) MIN

9/16 

(14.6 mm

)

1-7/8 (48 mm)

1-15/16 (50 mm) MIN

5-3/16 (132 mm)

1-7/8 (48 mm)

5/16 

(7.9 mm

)

4-9/16 (116.5 mm)

1-1/16 

(27 mm

)

13/16 (20 mm)

8-7/8 (225 mm)

1-3/16 

(30 mm

) MIN

11-1/4 

(285 mm

)

8-3/4 (223 mm)

30-5/16 (770 mm)

11-1/4 

(285 mm

)

1-3/4 

(44.5 mm

)

7-1/16 

(180 mm

)

45˚ 45˚

1-7/8 (48 mm)

1-3/4 

(44.5 mm

)

LIQUID PIPE

INDOOR UNIT ON/OFF SWITCH

DRAIN HOSE

GAS PIPE

SIGNAL RECEIVER

50˚

DRY

UP/DOWN (AUTOMATIC)

REAR

FAN

FLAPS

OPERATION LAMP

BOTTOM

STANDARD LOCATIONS OF WALL HOLES

COOLING

TIMER LAMP

50˚

RIGHT

65˚

SIGNAL TRANSMITTER

LEFT

AIR FLOW (INDOOR)

REQUIRED SPACE

BLADE ANGLE

THE MARK (

) SHOWS PIPING DIRECTION

FRONT PANEL FIXING SCREWS 

(INSIDE)

INCLUDING 

MOUNTING PLATE

GENERAL RATING 

NAME PLATE

TERMINAL BLOCK 

WITH EARTH 

TERMINAL 

(INSIDE)

UP AND DOWN WIND DIRECTION 

CONTROL BLADE MOVABLE RANGE

ROOM TEMP. THERMISTOR 

(INSIDE)

MODEL NAME 

PLATE

WIRELESS REMOTE CONTROLLER 

(ARC480A9)

RIGHT/LEFT 

(MANUAL)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR  PERFORMANCE

)

ABOUT 14-9/16 (370 mm)

ABOUT 13 (330 mm)

ABOUT 15-3/8 (390 mm)

GAS PIPE 

φ

3/8 (

φ

9.5 mm) CuT 

(THE LENGTH OF PIPE OUTSIDE 

THE UNIT: ABOUT 14-3/16 (360 mm))

LIQUID PIPE 

φ

1/4 (

φ

6.4 mm) CuT 

(THE LENGTH OF PIPE OUTSIDE 

THE UNIT: ABOUT 16-1/8 (410 mm))

DRAIN HOSE 

(CONNECTING PART 

I.D. 

φ

9/16 (

φ

14 mm) 

O.D. 

φ

5/8 (

φ

16 mm) 

(THE HOSE LENGTH OF OUTSIDE 

THE UNIT IS ABOUT 18-1/2 (470 mm))

WALL HOLE FOR EMBEDDED PIPING 

φ

2-9/16 (

φ

65 mm) HOLE

WALL HOLE 

φ

2-9/16 (

φ

65 mm) HOLE

3D091705

FTK18NMVJU

1-3/4 

(44.5mm

)

1-3/16 

(30mm

) MIN

11-5/8 

(295mm

)

10-3/8 (263mm)

29-3/8 (746mm)

7-1/16 

(180mm

)

39 (990mm)

ABOUT 14-3/16 (360mm)

ABOUT 15-3/4 (400mm)

ABOUT 17-5/16 (440mm)

ABOUT 18-1/8 (460mm)

5 (126.5mm)

1-7/8 (48mm)

39 (990mm)

5/16 

(7.9mm

)

ABOUT 14-3/8 (365mm)

1-15/16 (50mm) MIN

1-15/16 (50mm) MIN

10-7/16 (265mm)

1/2 

(12mm

)

11-5/8 

(295mm

)

1-7/8 (48mm)

9/16 

(14.6mm

)

1-3/4 

(44.5mm

)

ABOUT 17-3/4 (450mm)

2-3/8 (60mm)

13/16 (20mm)

45˚

45˚

THE MARK (

) SHOWS PIPING DIRECTION

REAR

TIMER LAMP

RIGHT/LEFT (MANUAL)

REQUIRED SPACE

DRAIN HOSE

55˚

LIQUID PIPE 

φ

1/4 (

φ

6.4mm) CuT

GAS PIPE 

φ

1/2 (

φ

12.7mm) CuT

RIGHT

65˚

UP/DOWN (AUTOMATIC)

15˚

SIGNAL TRANSMITTER

80˚

AIR FLOW (INDOOR)

OPERATION LAMP

10˚

MODEL NAME PLATE

BLADE ANGLES

BOTTOM

INDOOR UNIT ON/OFF SWITCH

FAN

COOLING, DRY

STANDARD LOCATIONS OF WALL HOLES

30˚

LEFT

SIGNAL RECEIVER

25˚

LIQUID PIPE

GAS PIPE

FLAPS

70˚

WALL HOLE FOR EMBEDDED PIPING 

φ

3-1/8 (

φ

80mm) HOLE

WALL HOLE 

φ

3-1/8 (

φ

80mm) HOLE

DRAIN HOSE 

(CONNECTING PART 

I.D. 

φ

9/16 (

φ

14mm) 

O.D. 

φ

5/8 (

φ

16mm)

(SPACE FOR 

MAINTENANCE)

(SPACE FOR  PERFORMANCE)

(SPACE FOR 

MAINTENANCE)

GENERAL RATING 

NAME PLATE

TERMINAL BLOCK 

WITH EARTH 

TERMINAL 

(INSIDE)

UP AND DOWN WIND DIRECTION 

CONTROL BLADE MOVABLE RANGE

ROOM TEMP. THERMISTOR 

(INSIDE)

FRONT GRILLE FIXING SCREWS 

(INSIDE)

(

)

INCLUDING 

MOUNTING PLATE

WIRELESS REMOTE CONTROLLER 

(ARC480A9)

3D091781

Summary of Contents for 19 SERIES

Page 1: ...Mode Powerful Operation Mode Wireless Remote Controller with backlit display Outdoor Unit quiet operation with backlight Auto Changeover Heat Pump only Auto Fan Speed Control Self Diagnostics with dig...

Page 2: ...l 09 9 000 BTU h 18 18 000 BTU h G Highest Q R 410A Heat Pump 12 12 000 BTU h 24 24 000 BTU h N Standard S High 15 15 000 BTU h __ Mid blank R X _ 09 NM VJ U 1 2 3 4 5 6 7 8 9 10 Unit Type Standard Co...

Page 3: ...rflow Dry H M L SL CFM 403 328 251 215 413 321 258 219 745 604 470 420 745 604 470 420 Sound Pressure Cooling H M L SL dB A 43 36 30 19 45 37 30 19 49 44 38 33 53 45 39 34 Sound Pressure Heating H M L...

Page 4: ...8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16 65 mm HOLE...

Page 5: ...ABOUT 16 1 8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16...

Page 6: ...m 10 7 16 265mm INCLUDING MOUNTING PLATE 39 990mm THE MARK SHOWS PIPING DIRECTION WIRELESS REMOTE CONTROLLER ARC480A8 3D091779 FTX24NMVJU 1 3 4 44 5mm 1 3 16 30mm MIN 11 5 8 295mm 10 3 8 263mm 29 3 8...

Page 7: ...AIN OUTLET I D 5 8 15 9mm HOSE FOR CONNECTION WITH DRAIN JOINT SERVICE PORT MANUFACTURER S LABEL C 3D092206 RK18NMVJU RX18NMVJU HANDLE 2 3 4 70 9 16 14 34 1 4 870 OUTDOOR AIR THERMISTOR 1 4 7 1 3 16 3...

Page 8: ...MINIMUM SPACE FOR AIR PASSAGE unit inch mm 11 7 16 291 3 15 16 100 20 11 16 525 1 15 16 50 1 15 16 50 1 15 16 50 3 15 16 100 3 15 16 100 4 1 8 105 6 1 2 165 13 3 4 350 13 3 4 350 13 3 4 350 6 13 16 1...

Page 9: ...0 mm ABOUT 13 330 mm ABOUT 15 3 8 390 mm GAS PIPE 3 8 9 5 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 14 3 16 360 mm LIQUID PIPE 1 4 6 4 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 16 1 8 41...

Page 10: ...Q1L R1T R2T R3T S20 S40 S70 S80 S90 X11A SA1 SWITCHING POWER SUPPLY OVERLOAD PROTECTOR THERMISTOR CONNECTOR SURGE ABSORBER V1 V2 V3 X1M Y1E Y1S Z1C Z2C Z3C ZF VARISTOR TERMINAL BLOCK ELECTRONIC EXPANS...

Page 11: ...n with chain KKF936A4 KKF936A4 Interface adaptor for DIII NET use KRP928BB2S KRP067A41 KRP928BB2S KRP980B2 Central remote controller DCS302C71 DCS302C71 Unified ON OFF controller DCS301C71 DCS301C71 S...

Page 12: ...12 www daikincomfort com SS RKN19 Our continuing commitment to quality products may mean a change in specifications without notice 2016 Houston Texas Printed in the USA Notes...

Reviews: