![background image](http://html1.mh-extra.com/html/daikin/19-series/19-series_specification-sheet_3217193003.webp)
2
www.daikincomfort.com
SS-RKN19
SS-RKN19
www.daikincomfort.com
3
Product Specifications
—
Indoor Units
System Performance
Nominal Capacity Class
9,000
12,000
18,000
24,000
Cooling Capacity (Rated)
BTU/h
9,000
10,900
18,000
21,200
Cooling Capacity (Min – Max)
BTU/h
4,400-10,200
4,400-13,300
5,500-20,000
5,500-24,000
Heating Capacity (Rated)*
BTU/h
10,000
13,500
21,600
24,000
Heating Capacity (Min – Max)*
BTU/h
4,400-13,000
4,400-16,400
5,500-24,000
5,800-27,600
SEER
19
19
18
18
EER
12.5
12.5
12.5
12.5
COP
4.06
3.8
3.6
3.5
HSPF*
9
9
9
9
Electrical Data
Power Supply
V/Ph/Hz
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
Minimum Circuit Amps
A
12.1
12.2
18.3
18.3
Maximum Overcurrent Protection
A
15
15
20
20
Power Consumption - Cooling
kW
0.72
0.87
1.44
1.70
Power Consumption - Heating*
kW
0.72
1.04
1.76
2.01
Indoor Wall-Mounted Units
Model Name
Cooling Only
FTK09NMVJU
FTK12NMVJU
FTK18NMVJU
FTK24NMVJU
Heat Pump
FTX09NMVJU
FTX12NMVJU
FTX18NMVJU
FTX24NMVJU
Moisture Removal
Q/hr
1.25
1.8
4.1
4.75
Airflow-Wet (H/M/L/SL)
CFM
417/297/244/141
434/311/247/145
713/579/448/403
713/579/512/403
Airflow-Dry (H/M/L/SL)*
CFM
403/328/251/215
413/321/258/219
745/604/470/420
745/604/470/420
Sound Pressure - Cooling (H/M/L/SL)
dB(A)
43/36/30/19
45/37/30/19
49/44/38/33
53/45/39/34
Sound Pressure - Heating (H/M/L/SL)*
dB(A)
43/36/29/25
45/37/30/26
49/42/37/33
53/43/37/34
Piping
Connections
Liquid (O.D.)
in.
Ø ¼
Ø ¼
Ø ¼
Ø ¼
Gas (O.D.)
in.
Ø ⅜
Ø ⅜
Ø ½
Ø ⅝
Condensate Drain
in.
Ø ⅝
Ø ⅝
Ø ¹¹/₁₆
Ø ¹¹/₁₆
Dimensions (H x W x D)
in.
11¼ x 30⅜ x 8¾
11¼ x 30⅜ x 8¾
11⅝ x 39 x 10⅜
11⅝ x 39 x 10⅜
Net Weight
lbs.
18
18
26
26
Outdoor Units
Model Name
Cooling Only
RK09NMVJU
RK12NMVJU
RK18NMVJU
RK24NMVJU
Heat Pump
RX09NMVJU
RX12NMVJU
RX18NMVJU
RX24NMVJU
Sound Pressure Level - Cooling/Heating*
dB(A)
46/48
49/49
54/54
55/55
Operating Range - Cooling
°F DB
50 - 115
50 - 115
50 - 115
50 - 115
Operating Range - Low Ambient Cooling**
°F DB
14 - 115
14 - 115
14 - 115
14 - 115
Operating Range - Cooling with
Optional Wind Baffle**
°F DB
-4 - 115
-4 - 115
-4 - 115
-4 - 115
Operating Range - Heating*
°F DB
5 - 75
5 - 75
5 - 75
5 - 75
Operating Range - Heating with Optional
Drain Pan Heater as applicable
°F DB
-4 - 75
-4 - 75
-4 - 75
-4 - 75
Max. Piping Length
ft.
65.6
65.6
98.4
98.4
Max. Piping Height
ft.
49.2
49.2
65.6
65.6
Dimensions (H x W x D)
in.
21⅝ x 26½ x 11⅛
21⅝ x 26½ x 11⅛
29 x 34¼ x 12⅝
29 x 34¼ x 12⅝
Net Weight
lbs.
55
60
97
108
*Applicable to heat pump models only