background image

2

www.daikincomfort.com

SS-RKN19

SS-RKN19

www.daikincomfort.com

3

Product Specifications 

 Indoor Units

System Performance

Nominal Capacity Class

9,000

12,000

18,000

24,000

Cooling Capacity (Rated)

BTU/h

9,000

10,900

18,000

21,200

Cooling Capacity (Min – Max) 

BTU/h

4,400-10,200

4,400-13,300

5,500-20,000

5,500-24,000

Heating Capacity (Rated)*

BTU/h

10,000

13,500

21,600

24,000

Heating Capacity (Min – Max)*

BTU/h

4,400-13,000

4,400-16,400

5,500-24,000

5,800-27,600

SEER 

19

19

18

18

EER 

12.5

12.5

12.5

12.5

COP

4.06

3.8

3.6

3.5

HSPF*

9

9

9

9

Electrical Data

Power Supply

V/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

Minimum Circuit Amps

A

12.1

12.2

18.3

18.3

Maximum Overcurrent Protection

A

15

15

20

20

Power Consumption - Cooling

kW

0.72

0.87

1.44

1.70

Power Consumption - Heating*

kW

0.72

1.04

1.76

2.01

Indoor Wall-Mounted Units

Model Name

Cooling Only

FTK09NMVJU

FTK12NMVJU

FTK18NMVJU

FTK24NMVJU

Heat Pump 

FTX09NMVJU

FTX12NMVJU

FTX18NMVJU

FTX24NMVJU

Moisture Removal

Q/hr

1.25

1.8

4.1

4.75

Airflow-Wet (H/M/L/SL)

CFM

417/297/244/141

434/311/247/145

713/579/448/403

713/579/512/403

Airflow-Dry (H/M/L/SL)*

CFM

403/328/251/215

413/321/258/219

745/604/470/420

745/604/470/420

Sound Pressure - Cooling (H/M/L/SL)

dB(A)

43/36/30/19

45/37/30/19

49/44/38/33

53/45/39/34

Sound Pressure - Heating (H/M/L/SL)*

dB(A)

43/36/29/25

45/37/30/26

49/42/37/33

53/43/37/34

Piping 

Connections

Liquid (O.D.)

in.

Ø ¼

Ø ¼

Ø ¼

Ø ¼

Gas (O.D.)

in.

Ø ⅜

Ø ⅜

Ø ½

Ø ⅝

Condensate Drain

in.

Ø ⅝

Ø ⅝

Ø ¹¹/₁₆

Ø ¹¹/₁₆

Dimensions (H x W x D)

in.

11¼ x 30⅜ x 8¾

11¼ x 30⅜ x 8¾

11⅝ x 39 x 10⅜

11⅝ x 39 x 10⅜

Net Weight

lbs.

18

18

26

26

Outdoor Units 

Model Name

Cooling Only

RK09NMVJU

RK12NMVJU

RK18NMVJU

RK24NMVJU

Heat Pump 

RX09NMVJU

RX12NMVJU

RX18NMVJU

RX24NMVJU

Sound Pressure Level - Cooling/Heating*

dB(A)

46/48

49/49

54/54

55/55

Operating Range - Cooling

°F DB

50 - 115

50 - 115

50 - 115

50 - 115

Operating Range - Low Ambient Cooling**

°F DB

14 - 115

14 - 115

14 - 115

14 - 115

Operating Range -  Cooling with 

 

Optional Wind Baffle**

°F DB

-4 - 115

-4 - 115

-4 - 115

-4 - 115

Operating Range - Heating*

°F DB

5 - 75

5 - 75

5 - 75

5 - 75

Operating Range - Heating with Optional 

Drain Pan Heater as applicable

°F DB

-4 - 75

-4 - 75

-4 - 75

-4 - 75

Max. Piping Length

ft.

65.6

65.6

98.4

98.4

Max. Piping Height

ft.

49.2

49.2

65.6

65.6

Dimensions (H x W x D)   

in.

21⅝ x 26½ x 11⅛

21⅝ x 26½ x 11⅛

29 x 34¼ x 12⅝

29 x 34¼ x 12⅝

Net Weight

lbs.

55

60

97

108

*Applicable to heat pump models only

**Cutting a jumper is required. Refer to installation manual.

Summary of Contents for 19 SERIES

Page 1: ...Mode Powerful Operation Mode Wireless Remote Controller with backlit display Outdoor Unit quiet operation with backlight Auto Changeover Heat Pump only Auto Fan Speed Control Self Diagnostics with dig...

Page 2: ...l 09 9 000 BTU h 18 18 000 BTU h G Highest Q R 410A Heat Pump 12 12 000 BTU h 24 24 000 BTU h N Standard S High 15 15 000 BTU h __ Mid blank R X _ 09 NM VJ U 1 2 3 4 5 6 7 8 9 10 Unit Type Standard Co...

Page 3: ...rflow Dry H M L SL CFM 403 328 251 215 413 321 258 219 745 604 470 420 745 604 470 420 Sound Pressure Cooling H M L SL dB A 43 36 30 19 45 37 30 19 49 44 38 33 53 45 39 34 Sound Pressure Heating H M L...

Page 4: ...8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16 65 mm HOLE...

Page 5: ...ABOUT 16 1 8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16...

Page 6: ...m 10 7 16 265mm INCLUDING MOUNTING PLATE 39 990mm THE MARK SHOWS PIPING DIRECTION WIRELESS REMOTE CONTROLLER ARC480A8 3D091779 FTX24NMVJU 1 3 4 44 5mm 1 3 16 30mm MIN 11 5 8 295mm 10 3 8 263mm 29 3 8...

Page 7: ...AIN OUTLET I D 5 8 15 9mm HOSE FOR CONNECTION WITH DRAIN JOINT SERVICE PORT MANUFACTURER S LABEL C 3D092206 RK18NMVJU RX18NMVJU HANDLE 2 3 4 70 9 16 14 34 1 4 870 OUTDOOR AIR THERMISTOR 1 4 7 1 3 16 3...

Page 8: ...MINIMUM SPACE FOR AIR PASSAGE unit inch mm 11 7 16 291 3 15 16 100 20 11 16 525 1 15 16 50 1 15 16 50 1 15 16 50 3 15 16 100 3 15 16 100 4 1 8 105 6 1 2 165 13 3 4 350 13 3 4 350 13 3 4 350 6 13 16 1...

Page 9: ...0 mm ABOUT 13 330 mm ABOUT 15 3 8 390 mm GAS PIPE 3 8 9 5 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 14 3 16 360 mm LIQUID PIPE 1 4 6 4 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 16 1 8 41...

Page 10: ...Q1L R1T R2T R3T S20 S40 S70 S80 S90 X11A SA1 SWITCHING POWER SUPPLY OVERLOAD PROTECTOR THERMISTOR CONNECTOR SURGE ABSORBER V1 V2 V3 X1M Y1E Y1S Z1C Z2C Z3C ZF VARISTOR TERMINAL BLOCK ELECTRONIC EXPANS...

Page 11: ...n with chain KKF936A4 KKF936A4 Interface adaptor for DIII NET use KRP928BB2S KRP067A41 KRP928BB2S KRP980B2 Central remote controller DCS302C71 DCS302C71 Unified ON OFF controller DCS301C71 DCS301C71 S...

Page 12: ...12 www daikincomfort com SS RKN19 Our continuing commitment to quality products may mean a change in specifications without notice 2016 Houston Texas Printed in the USA Notes...