background image

6

www.daikincomfort.com

SS-RKN19

SS-RKN19

www.daikincomfort.com

7

Dimensions — Outdoor Unit

RK09/12NMVJU, RX09/12NMVJU

18-1/2 (470)

3-13/16 (97)

16-1/16 (408)

1/2 (13)

1-1/8 (29)

1/2 (13)

12-1/8 (308)

12-13/16 (326)

OUTDOOR AIR THERMISTOR

9/16 (15)

26-9/16 (675)

1-5/16 (50)

5/16 (8)

HANDLE

11-3/16 (284)

1/2 (12.4)

13/16 (20)

GROUND TERMINAL

BRAND NAME PLATE

6-7/16 (164)

4-1/8 (104)

21-5/8 (550)

6-1/4 (159)

13/16 (20)

MINIMUM SPACE FOR AIR PASSAGE

5-7/8 (150)

1-15/16 (50)

5-7/8 (150)

3-15/16 (100)

1-15/16 (50)

1-15/16 (50)

3-15/16 (100)

1-15/16 (50)

UNIT: inch (mm)

11-13/16 (300)

WALL HEIGHT ON AIR OUTLET SIDE 

=LESS THAN 47-1/4 (1200)

IN CASE OF REMOVING 

STOP VALVE COVER AND 

TERMINAL STRIP COVER

LIQUID 

STOP VALVE 

(

φ

1/4 (

φ

6.4) CuT)

GAS 

STOP VALVE 

(

φ

3/8 (

φ

9.5) CuT)

4-HOLES FOR FOUNDATION BOLTS 

(M8 OR M10)

DRAIN OUTLET 

(I.D.

φ

5/8 (

φ

15.9mm) HOSE FOR CONNECTION 

WITH DRAIN JOINT)

SERVICE 

PORT

MANUFACTURER'S 

LABEL

C: 3D092206

RK18NMVJU, RX18NMVJU

HANDLE

2-3/4 (70)

9/16 (14)

34-1/4 (870)

OUTDOOR AIR THERMISTOR

1/4 (7)

1-3/16 (30)

12-5/8 (320)

ELECTRIC WIRE INTAKE

BRAND NAME PLATE

3/4 (19)

28-15/16 

(735

)

7/8 (23)

9/16 (14.5)

23-5/8 (600)

4-15/16 (125)

7/16 (11)

13-5/8 (346)

14-1/2 (368)

GROUND TERMINAL

MINIMUM SPACE FOR AIR PASSAGE

11-7/16 

(291

)

3-15/16 

(100

)

20-11/16 (525)

1-15/16 (50)

1-15/16 (50)

1-15/16 (50)

13-3/4 

(350

)

3-15/16 

(100

)

3-15/16 

(100

)

13-3/4 

(350

)

4-1/8 

(105

)

6-1/2 

(165

)

13-3/4 

(350

)

UNIT: inch (mm)

6-13/16 (173)

WALL HEIGHT ON AIR OUTLET SIDE 

=LESS THAN 47-1/4 (1200)

(INSTALLATION LEG 

PITCH)

MANUFACTURER'S LABEL

4-HOLES FOR FOUNDATION BOLTS 

(M8 OR M10)

DRAIN OUTLET 

(I.D.

φ

5/8 (

φ

15.9) HOSE FOR 

CONNECTION WITH DRAIN JOINT)

LIQUID 

STOP VALVE 

(

φ

1/4 (

φ

6.4) CuT)

GAS 

STOP VALVE 

(

φ

1/2 (

φ

12.7) CuT)

SERVICE 

PORT

IN CASE OF REMOVING 

STOP VALVE COVER AND 

TERMINAL STRIP COVER

C: 3D092224

Summary of Contents for 19 SERIES

Page 1: ...Mode Powerful Operation Mode Wireless Remote Controller with backlit display Outdoor Unit quiet operation with backlight Auto Changeover Heat Pump only Auto Fan Speed Control Self Diagnostics with dig...

Page 2: ...l 09 9 000 BTU h 18 18 000 BTU h G Highest Q R 410A Heat Pump 12 12 000 BTU h 24 24 000 BTU h N Standard S High 15 15 000 BTU h __ Mid blank R X _ 09 NM VJ U 1 2 3 4 5 6 7 8 9 10 Unit Type Standard Co...

Page 3: ...rflow Dry H M L SL CFM 403 328 251 215 413 321 258 219 745 604 470 420 745 604 470 420 Sound Pressure Cooling H M L SL dB A 43 36 30 19 45 37 30 19 49 44 38 33 53 45 39 34 Sound Pressure Heating H M L...

Page 4: ...8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16 65 mm HOLE...

Page 5: ...ABOUT 16 1 8 410 mm DRAIN HOSE CONNECTING PART I D 9 16 14 mm O D 5 8 16 mm THE HOSE LENGTH OF OUTSIDE THE UNIT IS ABOUT 18 1 2 470 mm WALL HOLE FOR EMBEDDED PIPING 2 9 16 65 mm HOLE WALL HOLE 2 9 16...

Page 6: ...m 10 7 16 265mm INCLUDING MOUNTING PLATE 39 990mm THE MARK SHOWS PIPING DIRECTION WIRELESS REMOTE CONTROLLER ARC480A8 3D091779 FTX24NMVJU 1 3 4 44 5mm 1 3 16 30mm MIN 11 5 8 295mm 10 3 8 263mm 29 3 8...

Page 7: ...AIN OUTLET I D 5 8 15 9mm HOSE FOR CONNECTION WITH DRAIN JOINT SERVICE PORT MANUFACTURER S LABEL C 3D092206 RK18NMVJU RX18NMVJU HANDLE 2 3 4 70 9 16 14 34 1 4 870 OUTDOOR AIR THERMISTOR 1 4 7 1 3 16 3...

Page 8: ...MINIMUM SPACE FOR AIR PASSAGE unit inch mm 11 7 16 291 3 15 16 100 20 11 16 525 1 15 16 50 1 15 16 50 1 15 16 50 3 15 16 100 3 15 16 100 4 1 8 105 6 1 2 165 13 3 4 350 13 3 4 350 13 3 4 350 6 13 16 1...

Page 9: ...0 mm ABOUT 13 330 mm ABOUT 15 3 8 390 mm GAS PIPE 3 8 9 5 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 14 3 16 360 mm LIQUID PIPE 1 4 6 4 mm CuT THE LENGTH OF PIPE OUTSIDE THE UNIT ABOUT 16 1 8 41...

Page 10: ...Q1L R1T R2T R3T S20 S40 S70 S80 S90 X11A SA1 SWITCHING POWER SUPPLY OVERLOAD PROTECTOR THERMISTOR CONNECTOR SURGE ABSORBER V1 V2 V3 X1M Y1E Y1S Z1C Z2C Z3C ZF VARISTOR TERMINAL BLOCK ELECTRONIC EXPANS...

Page 11: ...n with chain KKF936A4 KKF936A4 Interface adaptor for DIII NET use KRP928BB2S KRP067A41 KRP928BB2S KRP980B2 Central remote controller DCS302C71 DCS302C71 Unified ON OFF controller DCS301C71 DCS301C71 S...

Page 12: ...12 www daikincomfort com SS RKN19 Our continuing commitment to quality products may mean a change in specifications without notice 2016 Houston Texas Printed in the USA Notes...