26
-
4.2 When Using the DL Welding Power Supply
To use the DL welding power supply with the manipulator other than AII-B4/AII-B4L, the voltage
detection cable is required in addition to the coaxial power cable as described in Table 4.1.
(If you use AII-B4/AII-B4L, see Table 4.1 and choose a suitable coaxial power cable (for DL W.P.S
exclusive use) accordingly.)
4.2.1 Type of voltage detection cables
To use the DL welding power supply with the manipulator other than AX-V4AP/V4LAP, refer to
the table below and separately purchase the DL-dedicated voltage detection cable suitable for
each manipulator.
Table 4.2 Type of DL W.P.S-dedicated voltage detection cable
No.
Nominal
cable length
Applicable coaxial
power cable
Applicable manipulator
Remarks
L10667G 1.6
m
L-10621
AII-V6
L10667H 1.7
m
L-10622
L10667K 1.9
m
L-10624
AII-V6L
L10667L 2.0
m
L-10625
L10667P 2.3
m
L-10628
L10667S 2.6
m
L-10631
L10667W 3.0
m
L-10635
Note) Contact us for more of the voltage detection cables not listed in the above.
4.2.2 Assembling the voltage detection cable
A voltage detection cable shall be connected with the coaxial power cable laid along the shock
sensor cable. Turn the shock sensor cable and voltage detection cable around the coaxial power
cable, and then fix the cables with a cable tie, referring to Table 4.3 and Fig.4.4.
Fig. 4.4 Connection of voltage detection cable (for DL W.P.S)
Table 4.3 Turns of shock sensor cable/voltage detection cable
Coaxial power
cable
Turns and slack ofφ15
Remarks
L-10621 2
turns
L-10622 2
turns
L-10624 3
turns
L-10625 3
turns
L-10628
3 turns
L-10631 4
turns
L-10635 4
turns
When connecting the shock sensor
cable and voltage detection cable to the
coaxial power cable, be sure to follow
the specified turns (See Table 4.3) and
slack of φ15 (See Fig.4.4). Shortage of
the turns or insufficient slack may lead
to the snapping of shock sensor cable
and voltage detection cable, resulting in
poor welding performance.
IMPORTANT
Nominal cable length
Liner
Power cable
Gas hose
Shock sensor cable
Voltage detection cable
Connect to a nozzle holder
ASSY of the torch
Connect to the inside
of the manipulator
Summary of Contents for OTC RT3500H